HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 1
rt ( BCIS Home Log In User Registration i Hort Topic 1 Submit Surcharge Stats&Facts 1 Publications i FBC Staff SCIS Site Map Links ; Search i
Busines
Professig�1 �°''°` ` ser
USER:PPublicUUser
Regulation
Product Approval Menu>Product or Application Search>Apprrmtion List
Search Criteria Refine Search
Code Version 2010 FL# 7006.1
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved fogy use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-A plication.
FL# Tse Manufacturer Validated Status
FL7006_ Revision IKO Industries,Ltd Locke Approved
R8 FL#:FL7006.1 Bowden
History Model:Cambridge,Cambridge HD and CRC Biltmore AR (334)300-
Description:Laminated architectural fiberglass asphalt shingle 1800
manufactured at IKO's Kankakee,IL;Hawkesbury,Ont.;Wilmington,DE;
Sylacauga,AL and Toronto,Ont.plants
Category:Roofing
Subcategory:Asphalt Shingles
•Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Floridan an AA/ff0 employer.Cowriaht 2007-2013 State of Florida.::Privacy Statern ::Accessibility Statement:;Refund Statement
Under Florida law,email addresses arc public records.If you do not want your e-mail address released in response to a public-rewrds request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please cor>fact 850.487.1395_*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees lid under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address, provide the Department with an snail address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please dick here.
Product Approval Accepts:=WERE
SL`L'llfli\'.0 17H I L's
hftp://www.floridabuild ng.org/pr/pr app lst.aspx 4/28/2015
ACCl�DIi®
Co"' STRUCTION MATERIALS
TECHNOLOGIES
Qbc
a�
July 23, 2013
IKO Industries, Ltd
40 Hansen Road South
Brampton, ON L6W 3H4
Canada
Re: Shingle Installation Instructions for 2010 Florida Building Code
i
Sir(s),
PRI Construction Materials Technologies has completed a technical review and attached sealed shingle
instructions in compliance the 2010 Florida Building Code.
i
This review was completed based on the receipt of following evidence from IKO Industries, Ltd:
1) IKO Shingle Application Instructions—3-Tab.Shingles
(EN-3Tab APpins 8AGXEFS-2012-11_reformatted 2013-02-rev07/13-Florida)
2) IKO Laminated Shingles Application Instructions
(EN-Laminated Appins_8TTEFS-2012-04 reformatted 2013-02-rev07/13-Florida)
3) ASTM D3161 fest Report(FM Approvals Project No. 3040947)
4) ASTM D7158 Test Report(PRI Project No. IKO-091-02-01)
i
The attached instructions should be used in conjunction with the published manufacturer's application
instructions and appli�able code. In the event the instructions conflict, these instructions shall govem.
Regards,.
-Duc Nguyen;
VC T krrryfeAt
Attachments: A)IKO Shingle Application Instructions-3-Tab )>'E . IV e S5e1 C
B)IKP Laminated Shingles Application Instructions
237 ��3
��. NAN H /V !,Ifi.
tKO-osao2-o1 .`,Q;y�C,ENS'-.
�' No 65034 '2 op
L
V:P% STATE OF41
•
10
ASS,ON A �?Cs,.
lfilfa
PW Corstradao Materials Tectndcdes,LLC.6412 Bad Drive Tampa FUMO Tel:813-621-FM Fac 813521-5840 e4nail:rmlerialsteslirg@prirmt.oan WebSite:httpJAvww.priaffi.=n
IKO
Installation Instructions ford
3-Tab and Laminated S ,ogles
Page 2 of 3
I
IKO Shingle Application Instructions — 3-Tab Shingles
,(ASTM D 161, Class F—IKO Marathon 25 AR and CRC Superglass 25 AR)
(ASTM D311, Class F—IKO Marathon Ultra AR and CRC Superglass Ultra AR)
(ASTM D7158, CLASS H -IKO Marathon 20 and CRC Superglass 20)
I
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: Solidly sheathed and fastened deck conforming to 2010 FBC.
UNDERLAYMENT:/applied in accordance with building code requirements.For areas where the roof slope is
less than.4" per fdown to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the flit sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding cou+by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4"end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
NAILING:.Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate trough plywood or 3/4"into boards. Use 4 nails per shingle placed 6-1/8"above the butt
edge,approx. 1"and h3"from each end and 1/2"above each cutout. Drive nails straight so that nail head is
flush with, but not cutting into shingle surface.
NAILING ON STEE
P SLOPES:For steep slopes of 21"per foot(60°)or more,use 6 nails per shingle placed
as shown below. that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlightj.
STEEP SLOPES
I
1-10 1-VY
———� ----: sewac snap --
�
ruan.s NAILS
DO NOT NAIL INTO ORABOVE THE SEALNG STRIP
�`•JG:y�CE1VgF•'•y��i
No 65034 'Z L—
t
'n• cc G-5
STATE OF .-c02
NAIL
PW ComftucEon Materi&Tw.hWapes,LLC.16412 Badge Drive Tanpa,FL 33610 Tel:813-5215W F=81340-5W e-r�1:matedalstesting( dm#.can WebSfte:hV1AYww.*rnt.can
IKO
Installation Instructions for!
3-Tab and Laminated Shin,gles
Page 3 of 3
IKO Laminated Shingles Application Instructions
(ASTM D3161, Class F—IKO Cambridge AR and CRC Biltmore AR)
(ASTM D3161, Class F—IKO Grandeur)
I
NOTE: THESE INSTRUCTIONS SHALL BE USED IN CONJUCTION WITH IKO'S PUBLISHED
APPLICATION INSTRUCTIONS AND THE APPLICABLE CODE. IN THE EVENT THE INSTRUCTION
CONFLICT,THESE INSTRUCTIONS WILL GOVERN.
ROOF DECK: SolidIly sheathed and fastened deck conforming to 2010 FBC.
UNDERLAYMENT-/applied in accordance with building code requirements.For areas when;the roof slope is
less than 4" per fot down to 2" per foot, use 2 layers of underlayment conforming to building code
requirements, the fir t sheet overlapping the eave protection by 19",followed by full 36"widths overlapping
each preceding course by 19"or other Approved underlayments in accordance with the qualified application
instructions. For areas where the roof slope is 4" per foot or greater, cover the deck with one ply of
underlayment laid parallel to the eaves,with 2"horizontal laps and 4'end laps. Apply metal drip edges on top
of any underlay along rake edges and directly to the deck along eaves in accordance with building code
requirements.
i
NAILING:Use galvanized(zinc coated)roofing nails, 11 or 12 gauge,with at least 3/8"diameter heads,long
enough to penetrate through plywood or 3/4"into boards. Use 4 nails per shingle placed in the nail line 7-3/8"
below the top edge, a{pprox. 1"and 13"in from each end. Drive nails straight so that nail head is flush with,
but not cutting into shingle surface.
NAILING ON STEEP SLOPES:For steep slopes of 21"perfoot(600)or more,use 6 nails pershingle placed
as shown below. Enifure that no nail is within 2"of a joint/cutout of the underlying shingle. Seal down each
shingle at time of application with three 1"diameter(approx.size and thickness of a quarter)spots of asphalt
plastic cement placed under the shingle 2"above the bottom edge and equally spaced along the shingle.
Apply plastic cement in moderation since excessive amounts may cause blistering. CAUTION: Shingles
should seal to the underlying course when the factory applied asphalt sealant is sufficiently warmed by the
heat of direct sunlight.
NAILING-STEEP SLOPES APPLICATION
Use six rk&as shown_
t
7W
NAIL LINE
6 Mrt ri
r. ."
1
NAILS CEMENT
PROPER APPLICATION REQUIRES THAT THE NAILS PENETRATE BOTH THE OVERLAY AND UNDERLAY PORTIONS OFTHE SHINGLE
tr►1�-------.q
.�`��,'��rriHANH l yG�iA.
EN SF G�X010
No 65034 --2
ro'
STATE OF . p,C
10 N AL
t
i
PRI Corstruction Mderiels TecMdogie%LLC.i6412 Badger Drive Tempa,FL 33610 Tel:813.62144 Fax:813621-5840 e-mail:malerialstesting@priant.can WebSite:WAmww.pricmt.can
I