FL# FL16107-R5
Application Type Revision
Code Version 2010
Application Status Approved
Comments
Archived :1
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason,OH 45040
(513)770-6062
mwesterfield@clopay.com
Authorized Signature Scott Hamilton
shamilton@clopay.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Scott Hamilton
the Evaluation Report
Florida License PE-63286
Quality Assurance Entity Intertek Testing Services NA Inc.-EfL/Warnock Hersey
Quality Assurance Contract Expiration Date 12/31/2028
Validated By Gary Pfuehler
iii Validation Checklist-Hardcopy Received
Certificate of Independence FL16107 R5 COI Certification of Independence of Validation Entity-
Gary Pfuehler.ndf
FL16107 R5 COI Statement on Independence of Evaluation Entity-
ScottHamilton 120424.pdf
Referenced Standard and Year(of Standard) Standard Year
ANSI/DASMA 108 2005
ANSI/DASMA 115 2005
ASTM E1886 2005
ASTM E1996 2009
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
i
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh 109... 4/30/2015
Florida Building Code Online Page 2 of 5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/19/2014
Date Validated 12/26/2014
Date Pending FBC Approval 12/26/2014
Date Approved 02/23/2015
Date Revised 02/26/2015
Summary of Products
Go to Page Page 1/3
FL# Model,Number or Name Description
--1 W6 16 DSIE-1 7d: 4300, Double-skin Insulated EPS(exterior skin 27 ga. min.;
4301,4310`HDG,HDGL,HDGF, interior skin 27 ga. min,)Double-Car(97'to 16'2"wide)
66,66G,67, 67G,68,SP200, WINDCODE@ W6 Garage Door
SF200,SE200, 6200,6201,6203
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R5 II 1.04724-A-IBC-Rev03.odf
Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure:+38 PSF/-42 PSF Evaluation Reports
Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL157.Q7 R5 AE CBPC 1,07-14-A.,)df
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.2 02 W6-16 DSIE-11`171:4300, Double-skin Insulated EPS(exterior skin 27 ga. min.;
4301,4310,HOG,HDGL,HDGF, interior skin 27 ga. min.) Double-Car(97"to 16'2"wide)
66,66G,67,67G,68,SP200, WINDCODE@ W6 Garage Door
SF200,SE200,6200, 6201,6203
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16107 R5 II 104724-B-IBC-Rev03.13df
Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495
Impact Resistant:No Created by Independent Third Party: No
Design Pressure:+38 PSF/-42 PSF Evaluation Reports
Other:Doors with standard glazing meet the wind load FL1.61.07 R5 AE CBPC 1.30214-A.odf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.3 03 W6-16 PAN-21`153: 73,75,84A, Steel Pan(min.25 ga.)Double-Car(9'2"to 16'2"wide)
94,42,48,42B,48B,4RST,6RST, WINDCODE@ W6 Garage Door with Optional Impact-
GD5S,GR5S,AR5S,ED5S Resistant Lites
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL16107 R5 II 104710-A-IBC-Rev02.odf
Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495
Impact Resistant:Yes Created by Independent Third Party: No
Design Pressure:+36 PSF/-42 PSF Evaluation Reports
Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R5 AE CBPC 121212-A.1.odf
doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No
resistant(large missile impact).
16107.4 04 W6-16 PAN-21`153: 73,75,84A, Steel Pan(min. 25 ga.)Double-Car(9'2"to 16'2"wide)
94,42,48,42B,48B,4RST,6RST, WINDCODE@ W6 Garage Door
GD5S,GRSS,AR5S,ED5S
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL161.07 R5 II 104710-B-IBC-Rev02.odf
Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495
Impact Resistant: No Created by Independent Third Party: No
Design Pressure:+36 PSF/-42 PSF Evaluation Reports
Other:Doors with standard glazing meet the wind load FL.16107 RS AE CBPC 121.212-A.i.pdf
requirements of the building code but DO NOT meet the Created by Independent Third Party: No
impact resistant requirement for windborne debris regions.
16107.5 05 W6-16 PAN-21`143: 84A,94,98, Steel Pan(min. 24 ga.)Double-Car(9'2"to 16'2"wide)
48,48B,4F,4RST WINDCODE@ W6 Garage Door with Optional Impact-
Resistant Lites
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQv,tDgvyf4ngAXh 109... 4/30/2015
These Tables Are For GARAGE DOORS IN
One and Two Family Dwellings
Garage Doors Installed In Buildings with a
Mean Roof Height of 30' or Less Located in Exposures B,C or D
Table R301.2(4)
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF]
F11 60 EXPOSURE B 9'x 7' Door =+26.7 -30.2
F11 60 EXPOSURE B 16'x 7' Door =+25.6 -28.5
❑160 EXPOSURE C 9'x 7' Door = +32.4 -36.6 (1 story and max 15'
®1'60-EXPOSURE-C-16-X 7'-Door +31:0=�34�51 mean roof height)
F11 60 EXPOSURE C 9'x 7' Door =.+37.4 -42.3 (2 story and max 30' .
❑160 EXPOSURE C 16'X 7' Door t35.9 -39.9 mean roof'height)
1771160 EXPOSURE D 9'x 7'Door=+39.3 -44.4 (1 story and max 15'
❑160 EXPOSURE D 16'x 7' Door=+37.7 -41.2 mean roof height)
❑160 EXPOSURE D 9'x 7' Door=.+44.3 -50.2 (2 story and max 30'
❑160 EXPOSURE D 16'x 7' Door=+42.5 -47.4 mean roof height)
❑150 EXPOSURE B 9'x 7' Door =+22.8 -25.8
F11 50 EXPOSURE B 16'x 7' Door =+21.8 -24.3
171150 EXPOSURE C 9'x 7' Door=+27.6 -31.3 (1 story and max 15'
Ml 50 EXPOSURE C 16'x 7' Door=+26.4 -29.5 mean roof height
❑150 EXPOSURE C 9'x 7' Door=+32.0 -36.2 (2 story and max 30'
❑150 EXPOSURE C 16'x 7' Door=+30.6 -34.1 mean roof height)
❑150 EXPOSURE D 9'x 7' Door = +33.6 -38.0 (1 story and max 15'
❑150 EXPOSURE D 16'x'7' Door = +32.1 -35.8 mean roof height)
Ell 50 EXPOSURE D 9'x 7' Door =+37.9 -42.9 (2 story and max 30'
Ell 50 EXPOSURE D 16'x 7' Door =+36.2 -40.4 mean roof height)
Notes:
■ Secure existing bucks per the Product Approval or Design Professional
Instructions prior to installing the door. Have product-approvals
available at the time of inspection.
■ Glazing in Garage doors must comply with R301.2.1.2 (Glazing must
be impact resistant or shuttered)