May 4,2015
St. Lucie County Building Department An., O
Attn: Roof Permit Plan Review CW
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at
. 215 Olive Avenue St. Lucie County, Florida
Manufacturer: CertainTeed Corporation-Roofing
Profiles: Modified Bitumen Roof System NOA#14-0224.03
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Code: FBC 2010;Section R 905.10
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 1/4!'
Required Design Pressure: Zonel: -38.2 Zone2:-53.9 * Zone3: -101.4
Design Pressure: Zone 1-45 Zone 2-90 Zone 3 -123.7
Membrane: One ply of Flintlastic Gta torch adhered to base/ply sheet
Fasteners: Zone 1,Simplex Maxx Cap @ 9" O.C.at 2-inch lap and 18" O.C. in two,equally
spaced,staggered center rows
Zone 2,Simplex Maxx Cap @ 6"O.C. at 2-inch lap and 6'O.C. in two,equally
spaced,staggered center rows
Zone 3,Simplex Maxx Cap @ 6"O.C.at 2-inch lap and 6"O.C. in three,equally
spaced,staggered center rows
Underlayment: One ply of glasbase mechanically fastened using
Roof Decking: Existing 15/32" plywood sheathing to be nailed with W1 8D Ring Shank Nails @
6"O.C. per&6"O.C. Field Zone 1, &4"O.C. per& 6"O.C.field Zone 2,
4"O.C. per&6"O.C. Field Zone 3
The above approved,as per Florida Building Code Compliance acceptances, 2010 Florida Building Code,and the
Manufacturer's recommendations.