Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 DelawareAvenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com May 4,2015 St. Lucie County Building Department An., O Attn: Roof Permit Plan Review CW 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at . 215 Olive Avenue St. Lucie County, Florida Manufacturer: CertainTeed Corporation-Roofing Profiles: Modified Bitumen Roof System NOA#14-0224.03 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Code: FBC 2010;Section R 905.10 Exposure: B Mean Roof Height: 30' Maximum Pitch: 1/4!' Required Design Pressure: Zonel: -38.2 Zone2:-53.9 * Zone3: -101.4 Design Pressure: Zone 1-45 Zone 2-90 Zone 3 -123.7 Membrane: One ply of Flintlastic Gta torch adhered to base/ply sheet Fasteners: Zone 1,Simplex Maxx Cap @ 9" O.C.at 2-inch lap and 18" O.C. in two,equally spaced,staggered center rows Zone 2,Simplex Maxx Cap @ 6"O.C. at 2-inch lap and 6'O.C. in two,equally spaced,staggered center rows Zone 3,Simplex Maxx Cap @ 6"O.C.at 2-inch lap and 6"O.C. in three,equally spaced,staggered center rows Underlayment: One ply of glasbase mechanically fastened using Roof Decking: Existing 15/32" plywood sheathing to be nailed with W1 8D Ring Shank Nails @ 6"O.C. per&6"O.C. Field Zone 1, &4"O.C. per& 6"O.C.field Zone 2, 4"O.C. per&6"O.C. Field Zone 3 The above approved,as per Florida Building Code Compliance acceptances, 2010 Florida Building Code,and the Manufacturer's recommendations. Respectfully Submitted, Peter_B� Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789