HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
`*R
Fk3Cida,¢'erw "e ntd 8C1S Home I Log In User Registration Hot Topics :Submit Surcharge i Stats&Facts i Pubil ations i FSC Staff (,BCIS Site Map ?.Links ;Search
Busines
' Product Approval
Professisnal USER:Public User
Regulation
1:5 MM PfQed ict ADgmXaI M n�u>Product or Application Search>Appyg+rl n List>Application Detail
x r 1'
r� .. FL# FL10674-R8
fiq 46 A6 Application Type —Revision
Code Version � 2010
Application Status Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscor ing.com
E
Technical Representative Mel Sancrant I
Address/Phone/Email 1 Owens Corning PKWYp
Toledo,OH 43659
(419)376-8360
mel.sancrant@owensco'rnig.com
Quality Assurance Representative
Address/Phone/Email
Category ;, Roofing
Subcategory Asphalt Shingl s
c
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
LD Evaluation Report Hardcopy Received
z
Florida Engineer or Architect Name who Robert J.M. Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/26/2014 t
Validated By Jahn W.Knezevich,PE(
t
21 Validation Checklist-Hardcopy Received
Certificate of Independence FL10674 R8 Col Trinity ERD Cl-Nieminen odf
t
i
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161,Class F 2006
ASTM D3462 2007
ASTM D7158,Class H## 2007
l
Equivalence of Product Standards
Certified By
l
http:Hfloridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDgt�BN0P_Y V°Io2boQT... 6/19/2013
Florida Building Code Online Page 2 of 2
Sections from the Code !
r
Product Approval Method Method 1 Option D
I
Date Submitted 12/19/2012
I
Date Validated 12/20/2012
Date Pending FBC Approval 12/25/2012
Date Approved 02/04/2013 i
Summary of Products !
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab, laminated,starter,and hip&ridge
Shingles and Starters
Limits of use Installation Instructions
Approved for use in HVHZ:No FL10674 R8 �I er121912FINAL OC Asphalt
Approved for use outside HVHZ:Yes Shingles FL10674-R8.pdf
Impact Resistant: N/A Verified By: Robert J.M. Nieminen PE- 59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10674 R8 1,4E er121912FINAL OC Asphalt
Shingles FL10674-R3.Ddf
Created by Independent Third Party:Yes
i
Back Next
E
I
i
Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850.487.1824
I
The state of Florida is an AA/EEO employer.Copyright 2007-2010 State of Florida.;:Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
_ send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.
•Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are pubUc
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts: I
RIEM ® E M
i
xcurity�tz-rnir:�• ;
I
f
{
1
i
i
E
I
I
S
i
I
!j)
E
1
l
t
http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEYS V%2boQ'F... 6/19/2013
EXTERIOR RESEARCH & DESIGN, LI-C.
I Certificate of Authorization#9503
353 CHRISTIAN STREET, UNIT #13
TRINI-rYIERD OXFORD, CT 06478
PHONE: (203) 262-9245
EVALUATION REPORT FAX; (203) 262-9243
Owens Corning Evaluation Report 037940.02.12-112
One Owens Corning Parkway FL10674-RS
I
Toledo, OH 43659 Date of Issuance: 02/06/2012
Revision 2: 12/19/2012
SCOPE:
This Evaluation Report is Issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requiirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until suchtime as the named product(s)
changes, the referenced Quality Assurance documentation changes,11 or provisions of the Code that
relate to the product change. Acceptance,of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.!
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists'of pages I through 6.
Prepared by:
The facsimile seat appearing was authorized
X110 by:kobert Nierntnen,P.E.on 12/19/2012
This does not serve as an electronically signed
Robert J.M. Nleminen, P.E. document, Signed,sealed hardcopies have been
transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1 983 to the named client
CERTIFICATION OF INDEPENDENCE;
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial
distributing products it evaluates. interest in any company manufacturing or
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing, products it evaluates,
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product,
'
TRINITYIERD
ROOFING SYSTEms EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/Conditions of Use set forth herein,
]L STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161,
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007
3. REFERENCES:
Entity Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Voll� 3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
Miami-Dade(CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008
Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817 09 10/27/2010
Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817 10 10/27/2010
Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010
Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010
Miami-Dade(CER1592) FBC HVHZ Compliance 11-0411.03 06/16/2011
Miami-Dade(CER1592) FBC HVHZ Compliance 12-0309.01 07/19/2012
UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014
4, PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classc° ndS pnyne&are fiberglass
4.1.2 Berkshire@are fiberglass reinforced, 4-tab asphalt roof shingles,
4.1.3 a � � m »nl�
Designer Color Collection," TruDefinitionO ""=."ye- OakridgeO and WeatherGuard& np are
fiberglass reinforced, laminated asphalt roof shingles.
4.2 Berksh|re4' Hip & Ridge Shingles, High Ridge HP Hip
& Ridge Shingles and PnoEdge Hip & Ridge Shingles are fiberglass reinforced, hip and ridge
asphalt roof shingles.
4,3 Starter Strip Plus and Star-ter Shingle Roll are starter stripsfor asphalt roof shingles,
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVMZ.
5.2 Fine Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings mfthis product.
5.3 Wind Classification:
Exterior Research and Design, LLC. 'Evaluation Report 037940.02.12-R2
Certificate nvAuthorization#*sos | FL10674-Rm
/
Revision 2: 12/19/2012
TRINITYIERD
5.3.1 All Owens Corning shingles noted herein are Classified lin accordance with FBC Tables
1507.2.7,1 and R905.2.6.1 to ASTM D3161, Class F and/orJASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to V,,d = 150 mph (V,it = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 All Owens Corning hip & ridge shingles and Star-ter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and 8905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all wind zones up to V,,,,, =X150 mph (Vu,t = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data"Specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5,4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Coming and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
> Berkshireo shingles require minimum five (5) nails per`shingle.
WeatherGuardO HP shingles require minimum six (6) nails per shingle.
> Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's qublished requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.)
1
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing - Classic@ & Supreme:
j
Normal Mansard or Arse pare Nonnal
VVInd AXs" High Wind d" Mansard or Area porn
Ams,pstp visn"s nornmiss Areas ffladArs" High VAnd dsaivanot V
W.. Ar"Para vion"nonnslas Ar"s Vialms fusnes,
-4
6
E*p**W6n Vi.
Exterior Research and Design,LLC. j Evaluation Report 037940.02.12-R2
Certificate of Authorization#9503 FL10674-R8.
Revision 2: 12119/2012
Page 3 of 6
. ,
6.2.6 Minimum Nailing uernsnrevy:
It
0.2.7 Minimum Nailing - DuraUnn(D, TruDefinitio Duration@ Premium Cool &
TruDefinition� DurabnnmDesigner Color Collection:
Patten
Va
ir
5'%Pdq.d#'VPqsw6 Clam S";Palo,6P Aq.0slim
6.2.8 Minimum Nailing -TruDafinidnn��Oakhdge@, Oakhdge@: !
i
Exterior Research and Design, I.I.c !Evaluation Report 0a794o.o2.12-m2
|
ce,uwoamwvruu� � uFI-10674-118°, � "n�ysor ' Revision 2, zz/z9/amzo
Page 4mm6
TRINITY ERD
6.2.9 Minimum Nailing - WeatherGuard@ HP:
111111916 a&view
6.3 Hip & Ridge Shingles:
6.3.1 Installation of BerkshlrOl Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuar ' HP Hip and Ridge Shingles and ProEdge Hip& Ridge Shingles shall comply with
the manufacturer's current published instructions, using four (4) nails per shingle. Refer to
Owens Corning published information on wind resistance and installation limitations, including
the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's pU blished requirements, but not less
than FBC 1507.2.6 or 8905.2.5, Staples are not permitted.
63.3 Minimum Nailing - Berkshire® Hip& Ridge and High Ridge:
Flg.I
Fig.2
RE-MIftV"d
TapMm SMaNem
mitts
9
TOP L
V=od
P
ul
6.3.4 Minimum Nailing - Hip & Ridge with Sealant:
Fig.2-High Wbd Smixting Partum
{4 Nails)
rim
Fnd4n Shingle
Discard
2u. 2%0
Excess
Sealant lit
Strip 1 112"
T
0
Fastening SIM $"Exposure
Distance
12
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2
Certificate of Authorization#9503
PLI0674-RS
Revision 2: 12/19/2012
Page 5 of 6
IERD
(FTRINITY
6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge:
Fig.A s 4 Fig.C Hip&Ridge Shingle Fastening
P, Topl%w
Wind
Liotta
A i i Iloilo Kalil
'A
r
i
12"
6.3.6 Minimum Nailing - ProEdge Hip&Ridge Shingles:
Prevailing Standard
ng
I
Wind Dire-ation Fasta S"Urrt Strip Pattern
L
6-11itpownt r
Faten 7V 6-Filpmr,
C
Rod Ciavwft
7, LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdictio z n in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produ ce products covered by Florida Rule
9N-3 QA requirements,
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 (414) 248-6409; karen,buchmann@ut.com
- END OF EVALUATION REPORT
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2
Cer0ficate of Authorization#9503
FL10674-RS
Revision 2: 12/19/2012
Page 5 of 6