Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Engineering
Aral Consulting Engineers,Inc. Project Donaghey Res. File 13612570 Subject 106Wx88H, C&C Wind Loads Date : 4/15/2015 Location : 7932 Links Way,Port St.Lucie,FL 34986 Eng EA. Des¢in Wind Pressure,p.Equation 30.4-1(ASCE 7-30). Components and Cladding Low-Rise Buildings p (Envelope Procedure) with h<=60 ft qh :velocity pressure at h Gabled&Hipped Roofs GCp :Figures 30.4-1&30.4-2 GCpi : Table 26.11-1 Velocity Pressure Calculations: Velocity pressure qh is calculated in accordance with section 30.3. qh=Velocity pressure @ mean roof height(h) qh=Constant•Kh•Kzt•Kd•V 2 (Eq 30.3-1) Where:Constant = Numerical Constant (Section C27.3.2) = 55•[(Air density lb/cuft)/(32.2ft/S2)] [(mi/h)(5280 ft/mi)•(1 hr/3600 S)]2 = 0.00256 Mean Sea Level = 0.00 ft Air Density @MSL = 0.0765 Ib/cu ft (Table C27.3-2) Occupancy Category = II (Table 1.5-1) Exposure Category = C (Section 26.7.3) a = 9.50 (Table 26.9-1) Zg = 900.00 ft (Table 26.9-1) Basic Wind Speed = 170.00 mph (Figure 26.5-1 A-C) Mean Roof Height = 25.00 ft Where: Kh = Velocity pressure coefficient @ height h = 2.01•(Z/Zg)A(2/a)for 15 ft<=Z<=Zg (Table 30.3-1) = 2.01•(15/Zg)A(2/a)for Z<15 ft = 0.95 Kzt = Topographic factor (Figure 26.8-1) _ (1+K1•K2•K3)2 Topography = None Kzt @h = 1.00 Kd = Wind directionality factor (Table 26.6-1) = 0.85 qh = 59.44(psf) Aral Consulting Engineers,Inc. Project Donaghey Res. File 13612570 Subject 106Wx88H, C&C Wind Loads Date : 4/15/2015 Location : 7932 Links Way,Port St.Lucie,FL 34986 Eng E.A. Internal Pressure Coefficient,GCgi,,Table 26.11-1 lassification 0.1E O.la ! 60 5,000,000 1.00 O.ls 0.18 I External Pressure Coefficients,GCa,Figure 30.4-2(roof)and Figure 30.4-1(walls) .-. 400.000026.56 i 0.30 t -0.80 i - 200.00 26.56 0.30i -1.20 ! -2.20 W ® 25.00 26.56 _ 0.42 2.36 3.22 i 65.00 ! All 0.86 j -0.96 65.00 E All i 0.86 -1.11 - Design Wind Pressure,o:Equation 30.4-1. 5944 ;f 0 30 -0.80 f 018 -0.18 7.13 28.53 -58.26 -36.86 5944 0.30 ! -1.20 ! 0.18 1 -0.18 i 7.13 28.53 ! -82.03 + -60.63 I 59.44 ? 0.42 t -2.36 ; 0.18 M_ -0.18 ! 14.29 ro 35.69 i -151.06 {^-129.66 t 59.44 0.86 -0.96 i 0.18 -0.18 0 21 �61.61 ' -67.56 C -46.16 59.44 i 0.86 i -1.11 i 0.18 t -0.18 I 40.21 ! 61.61TTM -76.86 55.46 Positive and negative values of external and internal pressures are combined to determine four possible pressures: p1+uses GCp+and GCpi+ p1-uses GCp-and GCpi+ p2+uses GCp+and GCpi- p2-uses GCp-and 6Cpi- Roof Overhang Pressure,P.Equation 30.10-1. Wind pressures acting on the roof overhang(soffit pressures not included). M NNW EM M 10.18 1 -0.18 j -70.14 -48.74 1 5944 2.20 0.18 -0.18'-? ^-141.48 -120.08 ! 59.44 3.22 1 0.18 1 -0.18 -202.26 ! -180.86 E Aral Consulting Engineers, Inc. Project Donalihey Res. File 13612570 - Subject 106Wx88H, C&C Wind Loads Date : 4/15/2015 Location : 7932 Links Way,Port St.Lucie,FL 34986 Eng E.A. Notes:Structural design conforms to the Florida Building Code 2010,with wind Vult=170 mph in accordance with ASCE 7-10, Exposure"C".The design pressures given below are determined by using ultimate design wind speeds(Vult).The ultimate design speed can be converted to nominal design wind speed(Vasd)by using FBC-Table 1609.3.1 or the FBC-Equation 16-32[Vasd= Vult*(0.6)^'/z]. Building Dimensions: 85'x 45' Building Height: 25' Height of Window: 10' Dimensions of Window: 106 3/8"Wide x88"'High Edge Distance for Window: 1.0 feet Edge Distance for Zone 5: 5.0 feet Calculated Vult Design Pressures: p+_+61.61 psf. p-_ -76.86 psf. Vasd=170*(0.6)^'/z=132 mph. Calculated Vasd Design Pressures: p+_+36.97 psf. p- _-46.12 psf. Note:Vasd Design Pressures shall be used for window glazing.