Loading...
HomeMy WebLinkAboutEngineering 37 1/2"MAX. 71 3/4"MAX. �/ 3 DOOR FRAME WIDTH DOOR FRAME WIDTH I 6 3/4"MAX. CONCEALED 6 3/4" MAX. 12" Z HEAD/SILL SEE FLUSSHEET 5 BOLTS HEAD/SILL 3" C CORNERS CORNERS 3" Q A FOR DESCRIPTION A a II / It / \ II �, _A_.L I _.D_.L x_11__ s qO`3 G �+ } mrc Z m , �N � ')t o �\ lY 7— 'd r� ACTIVE I ";Z .;—A=fE•A Y�I�^� ,INAODVE,—:,—— z z D.L.OPG, n � D•L. OPG. i��$ �M� " 34"MAX. 34"MAX, fe;0-2 LEAF WIDTH LEAF WIDTH 0 Im TYPICAL ELEVATION TYPICAL ELEVATION SINGLE LEAF DOOR 18 SERIES 1800 ALUM. FRENCH DOOR SIDELITES ° APPROVAL APPLIES TO SINGLE (X) AND DOUBLE (XX) LEAF DOORS DOOR OPTIONS PJW�YfT,pelyRpg g WITH OR WITHOUT SIDELITES. Ir �w1TnMlerN� SIDE LITES CAN BE ON ONE OR BOTH SIDES OF DOOR. SEE SHEET 4 FOR DESIGN LOAD CAPACITIES. GLASS D.L.O. DIMS, =ft*Tp@%dtk*W7l D.L.O. HEIGHT (DOOR &SIDELITE) - FRAME HEIGHT - 13"THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THED.L.O. WIDTH (X DOORS & 0 PANELS) - FRAME WIDTH - 13.625" °0, m��$;:'a go REQUIREMENTS OF THE CURRENT FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY D.L.O. WIDTH (XX DOORS) = (FRAME WIDTH - 24 /2 HURRICANE ZONE (HVHZ). o u u x WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER 0 LOADS TO THE STRUCTURE. li ANCHORS SHALL DE AS LISTED, SPACED AS SHOWN ON DETAILS, ANCHORS DOORS/SIDELITES ARE RATED FOR LARGE AND SMALL MISSILE IMPACT. may, 1 EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. SHUTTERS ARE NOT REQUIRED. PyIB 7.p592, !S ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS �YW ARE NOT PART OF THIS APPROVAL. $ g A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. O�r�'�� drawi�—n MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS,THAT COME INTO W��—B4 CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF CURRENT FLORIDA BLDG. CODE SECTION 2003.8.4. sheet 1 of 15 144"MAX. 108"MAX. �u FRAME WIDTH FRAME WIDTH . I 8 3/4"MAX. 12"MAX, 12" 12' 12" 12" 3"MAX. Z n HEAD/SILL HEAD/SILL 3" SURFACE APPLIED 3" 3" HEAD/SILL 0 CORNERS 3" 3' FALSE MUNTINS 3" CORNERS F A MAY BE USED K O � U 11 /11 \ IL IIIf --L--- -L-1 \-L-- -- ILY \_A__ O M --r-- -- Ir- o 0 Q< N ii J /ii E ii\ ii \ 0 ===nll Li = {QL a lin F �i�• / �". ''�. \ � � � � � /`/:// / iii' 'r� \ ��• Q�i�f � -'�3'--- ---7(�-- ----I _ r II � 1-II it r �-il-- u n n u u u ¢s !L ACTIVE I I IN ACTIVE I INA p 3" 3ili 23 7/8' 23 7/8" MAX. 3" Imo- m z 23 7 8°MAX. m Z / ., D.L. OPO. D.L OPG. 12" '. D.L OPG. D.L OPO. 'n o W 0 0 34" 34"MAX. 34"MAX. t0 LEAF WIDTH LEAF WIDTH LEAF WIDTH 0 TYPICAL ELEVATION TYPICAL ELEVATION ( OXXO ) ( OXXO ) I I E 171O ucr RIIV I3D WITH PANEL SIDELITES WITH DIRECT SET SIDELITES r wMRINIgefN► $ $H 1 I@ 2o"I 0e ftorallf-ad* SIDELITE OPTIONS y lFI LAvl� MiM c �6$o q Engr.,JAVAO'AFIMAD Q n CML FIA.PE CAN. Q drowio W01-64 sheet 2 of 15 . 39 1/2"MAX. DOOR FRAME WIDTH I 36 5/8"MAX. 28 1/2" z i LEAF WIDTH WINDOW WIDTH 2 a 13 3/4"MAX 25 3/8" u. 8H3EAD/SIMAX. At I1EADfSitl D.L.OPG. (FIXED) O 0 0 CORNERS 13 8 1/4" 6"MAX. CL MAX. HEAD/SILL Iz a w CORNERS p�j 7 cy DO: I4(s1P-- 4. /8"ANN,GLASs44090 PVS INTERLAYER SAFLEX IIIG OY'SOLUTIA' .092"ALUM PANEL j \ gz a p i6 c--� 1/8"ANN.GLASS 5/8"THK, PLYWOOD 3 \\ m x I/ I� ,6 SILICONE SILICONE ,092"ALUM PANEL j GE 2800 GE 2800 © Q ._.^. 6 1 z z 24" pQa 5y D.L. OPG. Q Q f�0 M c� 12 ` nod'. �� 26 1f4" 01 Ht VENT WIDTH 7t M N 14 / 14 n r S / / z>In ALUM CLAD/PLYWOOD 00 PANEL NOTE: ^�" X10 X t"PH SMS 27•-tf2"1WIDTN MAX• SINGLE HUNG WINDOW IS INTEGRAL PART OF THIS DOOR, AT 6"FROM ENDS 33•-1 HEIGHT MAX. 00 2 WIND OYY D4QI� AND 18"O.C.MAX. C=�� GLAZING DETAILS / codf $ r 1rMllYeflakk TYPICAL ELEVATION l�— $1 rx 000 FOR DESIGN LOADCAPACITYSEE SHEET 4D�A� de .. SINGLE LFAF DOOR WITI; SERMq 2500 SINGLE HUNG NDW M$RY WINDOW INSERT OPTIOnn N Y Enar•..JAVA-0 ARM-AD, Q ,a CML 'FLX P.N.#70592 ®Q4 drawing no. WQ1-64 aheet 3 of I5 DOOR WITHOUT SIDELITES FORA-ME-WIDTH STATIONARY PANEL(0) OR DOORS WITH SIDELTfES SWIDETH �tr- V DESIGN LOAD CAPACITY- PSP ( ( DESIGN LOAD CAPACITY- PSP '!� SINGLE LEAF x Hoo I I DOOR GLASS TYPES DOOR DOOR PANEL DIRECT SET GLASS TYPES NOTE: p FRAME WIDTH FRAME HEIGHT 'A'. 'B'OR'D' FRAME HEIGHT FRAME WIDTH SIDELITE WIDTH SIDELITE WIDTH W.'B'OR'D' GLASS CAPACITIES ON THIS SHEET ARE Z n (INCHES) (INCHES) EXT.(+) INT,(-) ! (INCHES) (INCHES) (INCHES) (INCHES) tNL {-) BASED ON ASTM E1300-04 (3 SEC. GUSTS) 31 t/2 65.0 65.0 / 30 to 65.0 65.0 AND FLORIDA BUILDING COMMISSION'! ` a 78 3/4 DECLARATORY STATEMENT DCA05-DEC-219 371/2 65.0 65.0 f 36 i8 65.0 65.0 31 1/2 65.0 65.0 w . Jl 1/2 (X) 42 18 66,0 65,0 = j p $ 83 3/4 60(XX) 37 1/2 65.0 65.0 ; 48 18 65.0 65.0 a 4 31 1/2 65A 65A 54 18 85.0 65.0 t��Si 37 1/2 95 3f4 65,0 85.0 0 \\ 79 3/4 30 18 85.0 85.0 �u \ 37 1/2(X) 36 18 85.0 65.0 a 71 3/4(XX) 42 18 65.0 65.0 O n O 48 16 65.0 65.0 (030 {X) 18 65A 85,0 DOOR FRAME SIDELITE SIDELITE DOOR FRAME SIDELITE Z tab 4�4 31 1/2 (X) 38 78 65.0 _85.0 WIDTH WIDTH WIDTH WIDTH WIDTH - P 60(XX) 42 18 65.0 65.0 Q DOUBLE LEAF(XX)DOORS WITHOUT SIDELITES 83 3/4 48 18 85.0 65.0 ----- � .., CITY - PSP 1f2 ) 30 18 65.0 65,037 .-. DDDR DESIGN 36 18 66.0 85.0 LOAD CAPACITY DOOR GLASS TYPES 71 3/4(XX) FRAME WIDTH FRAME HEIGHT 'A'. 'B'OR'D' 42 18 65.0 65.0 w (INCHES) (INCHES) EXT.(+) INT.(-) 30 i8 65.0 65.0 !! / 60 78 3f4 65.0 65.0 31�{ }1/2 X) 36 18 85.0 j65.0 71 3j4 63.0 65.0 95 3j4 42 18 85.0 q 60 85.0 65.0 ' 37 if2(Jf) 30 18 85.0 G� \ \ Qa� c��j 7i 3/4 83 3j4 85 0 65.0 71 3/4 (XX) 36 18 65.0 '. \ \ ZS Q S to 665.0 65.0 71 3/4 65.0 95 3f4 65.0 DOOR SIZE MUST COMPLY EGRESS REQUIREMENTS PER FHC. DOOR FRAME WIDTH (0X0) OX SIDELITE SIDEUIE WIDTH HOOK FRAME WIDTHWIDWIDTH DOOR FRAM C: ! \ : W 0 "L L ACTNE 18" I DOOR FRAME WIDTH (XX) '" DIRECT SET MAX'SiDELITE WIDTH EXTERIOR (X)OR(XX) si SINGLE LEAP (X) DOORS WITH S.H. INSERT FRAMEOWIDTH {Oxx} (OXXO) .N a $a' ACTIVE o DESIGN LOAD CAPACITY - PSF (%XO) p�ppy�pQyy a o w o..x . �w ¢6wffIMM iM IIbAM -1 DOOR DOOR 6/8"PLYWOOD - Crr�► FRAME WIDTH FRAME HEIGHT .062'ALUM PANEL Arreegt��nr W. (INCHES) (INCHES) FXT.(+) INT.(-) PANEL SIDEUTE WIDTH DOOR FRAME WIDTH EAor:JAVAD AHMAO ax ralw'Mee 31 1/2 85.0 65,0 (X) 'CML=t i m 83 3/4 = ¢ Q\ EXTERIOR ♦'t AN, 70582:��'t S' n 33 1/2 65.0 65.0 y� m ACTIVE INACTIVE 9 v 5 II '' �. �Q�` drawing no. II PANEL SIDELITE WIDTH DOOR FRAME WIDTH _I J W01-64 EXTERIOR (XX) sheat ¢ of 15 HINGES: �U EXTRUDED 1/8" THK AND 7-1/2" LONG TWO-PART ALUMINUM BUTT HINGE (PART No. YH-650), THREE PER LEAF, 11-1/2" FROM LEAF TOP AND BOTTOM TO HINGE'S CENTER LINE AND ONE AT MIDSPAN. Z n W LOCK OPTIONS: IL OPTION #1 O STANDARD LOCK SET AND CYLINDER DEAD BOLT LATCH (FOR PRE-FABRICATED LOCK STILE PART d No. YE-802, WITH 2-1/8' BORE AND 2-3/8" BACKSET TO FR STANDARD LOCK SET), KEY a OPERATED ON THE EXTERIOR AND THUMB TURN ON THE INTERIOR AT EACH ACTIVE LEAFfA . G MANUFACTURER'S MANUALLY OPERATED CONCEALED ZINC DIE-CAST FLUSH BOLT ASSEMBLY WITH STEEL EXTENSION ROD, ALUMINUM FLUSH BOLT GUIDE, STAINLESS STEEL FLUSH BOLT ADJUSTMENT a 0 S PLATE AND PROTECTIVE MOLDED PLASTIC BOX FOR FLUSHBOLT AT THRESHOLD, AT 10-1/2' FROM O a¢c TOP & BOTTOM OF ACTIVE & INACTIVE LEAFS. (L' 00o a GEu800 GLASS TYPES A, B&D IL 3 OPTION # IL1 9 h MANUFACTURER'S STEEL THREE POINT LOCK MECHANISM ALTERNATE TO STANDARD LOCK SET AT J a mm ACTIVE LEAF (FOR PRE-FABRICATED LOCK STILE PART No. YE-837) WITH THROW BOLTS SPACER CONNECTED TO MORTISE LOCK SET, ENGAGING INTO FRAME HEAD AND SILL AND KEY OPERATED ON u z m THE EXTERIOR AND THUMB TURN ON THE INTERIOR S MANUFACTURER'S MANUALLY OPERATED CONCEALED ZINC DIE-CAST FLUSH BOLT ASSEMBLY WITH 9, STEEL EXTENSION ROD, ALUMINUM FLUSH BOLT GUIDE, STAINLESS STEEL FLUSH BOLT ADJUSTMENT PLATE AND PROTECTIVE MOLDED PLASTIC BOX FOR FLUSHBOLT AT THRESHOLD, AT 10-1/2" FROM TOP & BOTTOM OF INACTIVE LEAF. m rr OO 0 3 N Z NOTE: a TOP AND BOTTOM FLUSH BOLTS MUST BE ENGAGED DURING PERIODS OF HURRICANE WARNING. o <,a CI AZING DETAIL AT 'a DIRECT SET SIDELIT , O v comp o 1/8"HEAT STREN'D GLASS 1/8" HEAT STREN'D GLASS 3/18"HEAT STREWD CLASS .015' URETHANE ADHESIVE SAF X Il INTERLAYER'SOLR .070"INTERLAYER .090 PV8 INTERLAYER $ o SAFLEX IIIG BY'SOLUTIA' SAFLEX IIIG BY'SOLUM' f3iB�il<9'�VIRIP $ 'SAF-CLAS' POLYCARBONATE YE-833 o p g BY'SECURITY IMPACT GLASS' • �rlr lb t�wll�. YE-835 YE-824 1/8"HEAT STREN'D CLASS .015"URETHANE ADHESIVE 3/18"HEAT STREWD GLASS —/ZOQ.OZ c B P SILICONE ta 1/8"HEAT STREN'D GLASS F GE 2800 SIUCONE ICG- , z GE 2800 GE 2800 R9y�l prN it r y 2i cmA9$mac \ 13 14 m 0 15 !i!51 2 15 '> o m N 12 12 GLAZING ADAPTER OPTIONS I I p; C 'Engr:JAVAD'AHMAD. Q #10 X 3/4"PH SMS o CML' 1 ao AT 5'FROM ENDS o_ FIN.PE 9 g r\i C.0.N. 53B38 TYPICAL NDI 12 1/2"- D.C. GLASS TYPE 'A' GLASS TYPE 'B' E^ GLASS TYPE 'D' �'Ld ��I r GLAZING OPTIONS I"' I sheet 5 of 15 TYPICAL ANCHORS 1BY �(� p• SEE ELEVATIONS r, WOOD BUCK �/ 3 3/4"MIN. FOR SPACING DGE'D WOOD BUCK THROW BOLT e. EDGE O I PENETRATION .'EDCE�DISY• DIST. WOO TRUCTURE ,V.18 25 w �O " 8 N a� N ✓r I N OA27 1 + WOOD BUCKS AND METAL STRUCTURE NOT BY TRULITE V t7 TYPICAL ANCHORS TYPICAL ANCHORS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM i I g SEE ELEVATIONS y$EE ELEVATIONS Q' df 20 FOR SPACING F.OR SPACING AND TRANSFER THEM TO THE BUILDING STRUCTURE. n¢c EDGE' STRUCTURE m t/�7 O j e p 26 DIST.' TYPICAL ANCHORS: SEE ELEv. FOR SPACING a W;0, U. 0 1/4- DIA. TAPCON BY 'TIW' OR J N 1 0,/4" DIA. ULTRACON BY 'ELCO' (FU-177 KSI, FY-155 KSI) Q " w INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 0 1-1/2" MIN, PENETRATION INTO WOOD M THRU 1BY BUCKS INTO CONC. OR MASONRY v=i 1-1/4" MIN. EMBED INTO CONC. OR MASONRY d TYPICAL ANCHORS DIRECTLY INTO CONC. OR MASONRY SEE ELEVATIONS SPACING FOR SPACING 1-1/4" MIN. EMBED INTO CONC. OR MASONRY 3 !i #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) v INTO METAL STRUCTURES g a x ii ii co p STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) fit o 04 !i ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.) d M N (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) g ci W #12 SMS OR SELF DRILLING SCREWS Z g tkxj iii INTO MIAMI-DADE COUNTY APPROVED MULLIONS (MIN. THK. 1/B") (3 M_1 (NO SHIM SPACE) oo i!i! TYPICAL EDGE DISTANCE O y INTO CONCRETE AND MASONRY - 2-1/2" MIN. qq INTO WOOD STRUCTURE = 1" MIN. b INTO METAL STRUCTURE = 3/4" MIN. o ii 1 ii CONCRETE AT HEAD, SILL OR JAMBS f'c - 3000 PSI MIN. `0_ A10 X 3 4' PH. SMS. C-90 HOLLOW/FILLED BLOCK AT JAMBS fm - 2000 PSI MIN. 0 AT 4-31 FROM ENDS AND SEALANTS: "a 8 14"O.C. MAX.,TYPICAL 9 FRAME AND LEAF CORNERS, INSTALLATION SCREWS AT SILL AND ALL 10 B METAL PARTS CONNECTIONS SEALED WITH CLEAR COLORED SILICONE. gi 20 17 y!3 G O ' i w w11� Plwtlw .y B gAt*pmm Ws I �a e. 16 ALTERNATE Wa �ktlN�Beh + ALTERNATE Wa ' _ ngr;JAVAD AHMAD fifty g 2 'w(". MLM IMde' C n'S.d j FIA.PEA 7 • 'v 7­i� AN.•353880592 .. .• ° I: .o a•:• e.°:�.. TYPICAL ANCHORS TYPICAL ANCHORS .v'•°. v TYPICAL ANCHORS. SEE ELEVATIONS SEE ELEVATIONS SEE ELEVATIONS �� drow(ng9 no. EDGE GIST. FOR SPACING EDGE DIST. FOR SPACING EDGE DIST. FOR SPACING 1 W01—64 OPERATING UNITS sheet 6 of 15 1/4-MAX. 1/4"MAX. u SHIM METAL 1BY BUCK STRUCTURE-\ �000 z 20 TYPICAL ANCHORS SEE ELEV 17 ACTIVE FOR SPACING o. IL yy 4- 19 ............. 0 0 0 I- 23TYPICAL ANCHORS 0 R 4.4 16 217 22 D.L.OPG. FOR SPACING SEE ELEV.ING 0 0 30 26 Ir EXTERIOR L146 LEAF WIDTH 4 L DOORFRAMEWIDTHO 1/4"MAX. 1/4"W.- --\@L.CKOR OPTION'1 SHIM A :2 SHIM @LOCK OPTION 2 us (SEE SHEET 5) 28Y WOOD UCK OR TYPICAL ANCHOR; ODD UCTURE SEE ELM INACTIVEWW FOR SPACING� ACTIVE ACTIVE INACTIVE" Ad o 0 a 20 20 1 9 LOCK OPTION I EXTERIOR TYPICAL ANCHORS CHORS OR SEE ELEV. 19 LOCK OPTION 2 FOR SPACING (SEE SHEET 5) DOOR FRAME WIDTH 0 "IfA lbi flerik ALTERNATE ft0fAWA ACTIVE INACTIVE soft 26 24 Mimi 6.dc Dot Y Enqt:JAVAD AHMAD A CIVIL #lox PH Lis. 1-511 FIA. 70592 538 1 4-3/41 Q SEND AND 14'O.C. MAX. OPERATING UNITS TYPICAL 19 LOCK OPTION 2 EXTERIOR (SEE SHEET 5) drawing no. 3 POINT LOCK ON ACTIVE LEAF OPTION W01-64 j TYPICAL ANCHORS PANEL SIDELITE INSTALLATION DETAILS SEE ELEVATIONS EDGE DIST. FOR SPACING • o 0� W 0 M U 6 0� v F 010 X 3/4"PH SMS Q' AT 4-3/4"FROM ENDS O a a a AND 14"O.C.MAX. a #10 X 3/4"PH SMS g SILICONE AT 4-3/4'FROM ENDS -gg AND 14"O.C. MAX. Q g TYPICAL S 1/4"MAX• SCREWS NOT REQUIRED. JLJFOR O SHIM . O A70 X�4"PH. SMS, J CONNECTIONS/DOOR JAMB S AT 4-3 4"FROM ENDS AND O b I .• SILICONE 14"O.C.MAX.,TYPICAL 32 n - 17 $ to GI I I TYPICAL ANCHORS � a a it EE _I FOR SPACING .a _o = O IZ in J •.. a+ g 3 �` o II II 16 21 7 8 i!i! MOP.. EXTERIOR fE Rim I II � PANEL SIDELITE WIDTH DOOR FRAME WIDTH .�!� FRAME WIDTH a ;!i 8833 1�i oil 11 1 g P�Dujy�wilh M�laiY 2 SILICONE SILICONENeq� © © B & S SL. K A 2 ALTERNATE . . o �_ -- nor.J CMggL Its :.: :. E PE Q70 02EDGE DIST, TYPICAL ANCHORS ,.a'• ° NPICAL ANCHORS � •d SEE ELEVATIONS EDGE DIST, SEE ELEVATIONS ' FOR SPACING FOR SPACING drawing no. PANEL SIDELITE UNITS I I W01-64 I t sheet$ of 15 SEE ECALLkVAANCHORS DIRECT SET SIDELITE INSTALLATION DETAILS EDGE GIST. FOR SPACING Z .h"• t G J FW 4 W O 0 8 it 31 5 y p ei i!itcy jI Q&Qe ii 0 rx LL z+�_ II I i!it 9 11 p ;II R o � T li�I SCREWS NOT REOD. S ai II�1 1I4"NA><.'• O FOR SDDDR JAMB O Q 0 III SHIM .• 5 M CONNECTION o 3 N M M o 3Iz w 31 c _ o it 77 M S ,J !I!I TYPICAL ANCHORS - - - _ - - -- j!!! SEE ELEV. ".'�'•' - - - - - - - - - - - - II II FOR SPACING I.I! Ie !I!I ".a 18 23 Cpgi 'O47 EXTERIOR a5 e i.I. D.L. OPO.OPG. 21 DIRECT SET SIDELITE WIDTH DOOR FRAME WIDTH z b G Ilj CHANN OPTIONAL II j! FRAME WIDTH II_I jI I 31 5 f'ilOpUf.Y �10d/► •� E& NO c u u x O \� '.. fulVkglw'DAt ::_-<. .::::::.�:.:.::>>..:................... EnBr.JAVN AHlMAO. IIM DrAe/ c Y C/ 'n °'<EDGE DIST.•' TYPICAL ANCHORS Y 5 b SEE ELEVATIONS o FOR SPACING o drawing no. DIRECT SET SIDELITE UNITS W01—64 I sheet g of 75 4.D00------ ITEM # PART # I REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS �V 33g 1.594 .250 1 YE-832 t DOOR FRAME HEAD/JAMB 6063-T8 r3 1 1.492 � 989 121 � 2 YE-810 1 STD. THRESHOLD 6063-T6 - � Q 2.117375 2A YE-1820 1 HI-RISE THRESHOLD 6063-T8 - 1- .070 .082 -� 2B YE-840 1 OPTIONAL THRESHOLD 6083-T8 - F N 2 781 1.494 5 YH-809 AS REQD. SIDELITE FRAME 8063-T6 - Ej 240 1547 6 YE-801 2/LEAF DOOR LEAF TOP AND BOTTOM RAIL 6063-T6 7 YE-803 1 DOOR LEAF JAMB - HINGE SIDE 6063-T5 I DOOR FRAME HEAD 22 PRESSURE PLATE 9 SNAP CAP a YE-802 I DOOR LEAF - LOCK SIDE 6063-T5 - w SA YE-837 I DOOR LEAF - LOCK SIDE(3 POINT LOCK) 6083-T5 - 718 1-.513 ,513-1 9 YE-806 2/LEAF SNAP CAP FOR DOOR LEAF&SILL 6063-T5 2 .973 1 973 10 YE-618 AS READ. COVER PLATE 8083-T5 - 0 0 t6- L.-J-70'.-r �- 1.217 1.514 _412 YE-624 4/LEAF GLAZING CHANNEL 6083-Te - � W.050 �0 13 YE-835 AS REQD. EXTERIOR GLAZING LEC 6063-T5 - Q di fi &G 12 .853 1.087 14 YE-833 AS REQD. INTERIOR GLAZING LEG 8063-T5 - {L? g 11 14 GLAZING CHANNEL EXT. GLAZING LEG INT. GLAZING LEG 15 YH-623 AS REQD. GLAZING GASKET VINYL DUROMEIER 75 SHORE A 0 11 g 1 ^-1.704 (5) 010-24% 1/2"FH. MS. 18 YH-4004 AS REQD. WOOL FIN WEATHERSTRIPPING 187 X ,260) - ULTRAFAB O 1 STA INLESS 17 YH-822 AS REgD. BULB WEATHERSTRIPPING (.194 % .260) VINYL DUROMETER 75 SHORE A 19 GU 1/ACTIVE LEA 3 POINT LOCK MECHANISM (OPTIONAL) S.STEEL - 20 YH-810 AS REQD. FLUSH BOLT ASSY. SERIES 1202 ZINC DIECAST .070 21 YH-650 3/LEAF BUTT HINGES,AT 11-1/2"FROM ENDS & MIDSPAN ALUMINUM WITH SS PIN 4.250 22 YE-805 4/LEAF PRESSURE PLATE-TIE ROD 6063-T5 2-1/2°LONG L1 Q 3.758 23 YH-630 2/LEAF 3/8"DIA. THREADED ROD STEEL - 3 $ 24 YH-618 2/LEAF 3/8"-16 HEX FLANGE NUT STEEL - Q 8 25 YH-041 AS REQD. INSTALLATION SCREW HOLE CAP PLASTIC -28 YE-842 2/LEAF FLUSH BOLT GUIDE, 1-1/2"LONG 6063-T6 - _27 YH-656 2/LEAF FLUSH BOLT ADJUSTMENT PLATE S. STEEL - pOO ,,_.ITOP/BOTTOM RAIL 28 YH-681 1 PROTECTIVE BOX NYLON -t4.136-1 29 YH-616 1 LOCK SET ASSEMBLY - LEVER OR KNOB TYPES.07I Fr 30 YH-617 1 DEADSOLT ASSEMBLY - - M 31 YH-816 AS REDD. INSTALLATION SCREW COVER STRIP 6063-TB - ^W WJ .450 32 YH-806 AS REQD. SIOELITE FRAME MULLION 6063-T6 m 1.834 3.555 O 21 HINGE ASSEMBLY az � 7 HINGE STILE 4.000 � c 8 o� k--4,151 fpQw�{Q fI 1.500 "a wlr 4110�RaYk 2.125 2.12L070 1.834 sm 1 .535 1.490 p� ' 2 19 4 71 5 SIDELITE FRAME 5 .a 6 LOCK STILE 1.990 ` W y 1.990 .110 4.189 070 .1110 1.990 Q 110 En AH Q(. �lA �pLL'?d592 $ 2.610 i�.A �`J336 �• 1.834 2.124 1.500 L 1.5100 `•' i 1 L5� 07a .500 900 1- .078 078 201 Browing no. 4.662 -J I-4.000----I a.DDo 4.000 '1` W01-64 BA LOCK STILE +.,�11�• ;,�• (FOR 3 POINT LOCK OPTION) 2 STD. THRESHOLD 2A HI-RISETHRESHOLD 2B OPTIONAL THRESHOLD sheet 10 of 15 a X , N a O / a / N w . ae fT A 0 O X t 2 N i N W 4 d - r - v .� O .g- I N N C N O m tF vw zv a � �c gD J CZ r � z V v a o F---17-01 revisions: SM IBM ALUM FMCH DWR W/5MaM(LNl) AL-FAROOQ CORPORATIONno date a 0. O ualc 3 8 1' D OlM.07 NO BCFiAlIGE0710S SIffET ENGINEERS&PRODUCT DEVELOPMEM E 07.OJAB CaE7AL 1ffK90N TRULITE WINDOW & DOOR SOLUFIOK LLC 1235 S.W.87 AVE f I to dr.by. HAMD F 0aA2.10 WWIF.WLE REV6m 8130 N.W. 74TH AVE. MIAMI,FLORIDA 33174 c 11 zz.10 REV.Pae acro cmeuElrts MEDLEY. FL 33166 1E�(3os)zs4sa0o FAX(30x7262-697a {r x 0x.16.11 UPDATED FOR 2010 FBC TEL(305)887-2646 FAX(305)883-1309 COMP—ANL WO7-64ANP � I z Qat N o. a STAINLESS SiEEI FLUSHBOLT V C, ADJUSTING PLATE WITH(2) BB UNDERCUT S. oO� noIL us EL°CROW FIN SEAL 4 FLUSH BOLT GUIDE 0: °0 0 WEATHERSTRIP _ AND ADJUSTMENT PLATE ASSEMBLY �ZRn_d 2'LONG ALUM, I a FLUSHBOLT FRAME E, ATTACHEDCHED TO FRAME SIILFS AT TOP(SHOWN) O AND O MIA. g CONCEALED FLUSH BOLTS O 3 N (2)p,0-24 POINT B K UFIDERCUT,FH.NS C 3�M TOP FLUSHBOLT ASSEMBLY o§ Do (2)B,D-24 POINT B U OERCUT,FH.NS K q CONCEALED u S C uC ,-,/2'LONG ALUM. I FLUSH BOLTS FLUSHBOLT AIDE, � ny'�.f IIBYICQD ATTACHED TO FRAME STILES AT TOP AND BOLTON(SHOWN) e m o aft COVER PLATE WITH DOUBLE ROW FIN SEAL �S1.�4 WE STAINLESS STEEL FLUSHBOLT ADJUSTING PLATE WITH(2) Engr:JAVAD AHNAD'•. nY •T 993 8-24 UNDERCUT2 SMS. q �C. Cm A.N 3538 92 LL ` By �J _0 O O drawing no. EMNIOR BOTTOM FLUSHBOLT ASSEMBLY ' ` sheet 2 of W01-6 4 4 TYPICAL ANCHORS 3 SEE ELEVATIONS ' 3/4°MIN. EDGE DIST. FOR SPACING THROW BDLT e. I PENETRATION •.,o�.•• '°e r F o •a•... 2OZ 6• w QF uf� C ! V as da A l 27 1 C 8 v 4 17 U' er{yyl B aowg zo I' I 0M § 8 20 S10 SMS O EE ELEV. Q;Nq O FOR SPACING G7j r BA 1A 0 fn J � Z c 11A 4 0 LL S B1 �� WEEPHOLES• `�3 $ o a W, = 1" LONG WEEP NOTCH AT EACH END o 4 Do --------------- T(2 SILICOX10%3/4°PH. SMB. I 19'GE 2814"O CAT /MA)6 TYPICAL4'FROM ENDS ANO whlllTafk120 .02 O 2IjI18 IEnv'aAMADAHALTERNATE CA�QL�7 i i IF C.A�1(.ti 7 � V v ,v 'v . O °27 a B '•° °::•. ° . `o.' d. < .;r.v. drawing no. o•v TYPICAL ANCHORS ° •'v TYPICAL ANCHORS WO 1—64 BINGLE (X OPERATING UNITS W S.H. WDW EDGE DIST. SEE ELEVATIONS EOCE DIST. SEE ELEVATIONS I �� FOR SPACING FOR SPACING sheet'13 of 5 1/4"MAX. f a SHIM 4 OE 1 F 1 .:1/4•MAX, 1 VENT WIDTH O 1 . SHIM Z 20Y ODD BUCK WOOD UCTURR 3 #10 SMSQ a o' I SEE ELEV. TYPICAL ANCHORS i 418 FOR SPACING SEE ELEV. O 7A 17 FOR SPACING I 4 a°0 u p� a w� 0 AL Q f pyo•o t7 s 20 JO 3A EXTERIOR 22 7 21 1s J Z?uMN�i d TYPICAL D-j EE D.L. OPO. FOR SPACING 0 S.H.WINDOW WIDTH LEAF WIDTH DOOR FRAME WIDTH .^ 29 LOCK OPTION 1 ^' OR 19 LOCK OPTION 2 LJ (SEE SHEET 5) Q 1/4°MAX. o� I SHIM V H 1 SHIM SPACE 18Y WOOD BUCK, - g Z METAL ' STRUCTURE - 17 TYPICAL ANCHORS O 24 SEE ELEV. FOR SPACING a �e9 e. tLij o rUODjVCT RE11,116= ma 2027-1/2-MAX. 2 18 na�llFhits VA od will tit blaitL. s a a 17 PANE/l.WIDTH 7 21 -1?b •Q2 _ a S szoraw Dow `7 EXTERIOR �a a q g N o d TYPICAL ANCHORS LEAF WIDTH •N as o SEE ELEV. �o wLLux FOR SPACING DOOR FRAME WIDTH '•I'j� I"•,, i 29 LOCK OPTION 1 OR i 19 LOCK OPTION 2 FLA �&i 7a592'•;,•; $ (SEE SHEET 5) 1'�.11•C:AIN.b5Js y U a drawing roj W01-64 ' 1�.1 sheet 14 oT 15 2.220IT8M# PART A REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS (� � E .(_ 1A YE-169 1 FRAME HEAD 6083-75 - 1f e .889 .055 1.327 2A YE-167 1 FRAME SILL 608345 - Z .8207 I 3A YE-102 2 FRAME JAMB_ 6063-T5 - O J .880 1 4A YE-152 I FIXED RAIL 6083-T5 - {: 21 SA YE-151 1 VENT TOP RAIL 6083-T5 - Q m a al BA YE-168 1 VENT BOTTOM RAIL 8083-T5 - LL o 8 lA FRAME HEAD 7A YE-92 2 VENT JAMB 6063-T5 - 0 IS IL 4 812 8A YS-4 AS REQD. GLAZING BEAD ALUM94UM ROLL FORMED it 0 10A - 2/VENT BLOCK&TACKLE BALANCE - - 0 n -°1 .082 11A YH-622 AS REQD. BULB VINYL-SINGLE ROW' PVC OUROMETER 75 SHORE A T_ 13A YH-5D9F AS REQD. PILE-SCHLEGEL.187 X.250 - FIN SEAL(DOUBLE) 0 0.Q Q S .88!1 7 14A YH-504 2/VENT VENT LATCHES NYLON/CELCON AT 11"FROM ENDS �=1 1 AAA YH-515 2/VENT CAM LOCKS ZAMAK AT 11"FROM ENDS ^-I 1.082 16A #10 X 3/4" 8 FRAME ASSEMBLY SCREWS CRS PlATEO,PH 3MS - 10A �8% 1° 2 FIXED RAIL SCREWS CRS CAO PLATED,PH SMS 4A FIXED RAIL 17A #8 X 1-1/4" 4/VENT VENT ASSEMBLY SCREWS CRS CAD PLATED,PH SMS Q W f 18A YH-590 1 REINFORCING BAR .312') STEEL - �_ -^(.BB9(°- SINGLE HUNG WINDOW INSERT FOR SINGLE (X)DOOR ( A 1.1 BI 7 I I .055 1__ 1.825 / 25 ap 5A VENT TOP RAIL 1.582 Z m .055 NO 3.125 2.663 2.887 -111. 1.125 dI l' �'L 1,070 .055.812 c $ --1,8121 ° Fd 7 PROD00 RBVWW swMRn�kAfl► u 12 6A VENT BOTTOM RAIL 7A 1W. y u VENT SIDE RAIL / 2.174 '/� •S o��$ d .930 Lr ae rux c 3/4"WEEP NOTCH " AT EACH END OF 1,292 SCREEN RETAINING LEG A55 2.104 .055 .EnQr.JAVAD AHMAD 3.527 3.027 --�. •CIVIL, - 3 .872 FIA,PE'3 7Ub92 3 CAN,3536 n a1s °I(1 t.n9 �14\� F� 8 7 t. t S.H. VENT CORNER DETAII drawing no. S.H. FRAME CORNER DETAIL W01—64' 2A FRAME SILL 3A FRAME JAMB sheet 1$of 15