HomeMy WebLinkAboutProduct Approval Regulation
rAMOM OWN=
Busi11�5Prof I
COMMUSM
,rctuveo
Product Manufacturer Gulf Coast Supply&Manufacturing, WC.
Address/Phone/Enna(! y4=S.W. 449th Street
���
t in•r3e hOe l�f•L 322
(352)498-7852
ray¢.„guifcoastsupply.com
AuUlorized mature Ray Bowen
ray@gulfcoastsuppty_aom
i ecrinical Kepresentative
Address/Phone/EmaV
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Lkensed
Florida Professional Engineer
' Evaluation Report-hardcopy Received
Florida Engineer or Arr.ffitect Name who developed Terrence E. Wolfe
the Evaluation Report
Florida License PE-44923
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Dane 04/12/2024
Validated By Locke Bowden
V Validation Checklist-Hardcopy Received
Certificate of Independence B-11651 Ri COI Letter gfC,rfif,adf
R.11651 R11 COI Letter of Name chanoe.odf
Referenced Standard and Year{of Standard} Standard Year
FM 4471 1995
FM 4471 2010
TAS 100 1995
TAS 125 2003
UL 1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
h":1MorW&jW4Mj1pr4V QWDWQFcSQ962f1'rZeCS'tlWAWI w97Hcg'3 ft7rS2rj&gBAlZv%0%3d%W 115
1'14/2DI5 Florida Build riq Code Onfir e
�ecttons from the Code
Product Approval Metmoo Method 1 option W
Date Submitted 021151201:.
Date Validated 02/23/2022
Date Pending FBC Approval 02/29/2012
Date Approved 04/03/2022
SsAr " II !I r#
r-Oinpage
tea a r w Cti mp 5 t*staff r aeReaesg comet S01`P>yeaa s
811651 111 11 Alum S V OlimoDetaiis odf #E
VI!S 'W-Twremm lv lam,Pte.44923 t
Cngftdbrfi 11116dPIMEW-YeS
- } # g_t1651 R1 Alum 5V Q:jW Panel over.5 Plywood
�deiais 3btt ae�itaf FZ2 NOIWHVHZ Roof2Li10FormsLo f
F f
Ram-momium Qff il,* x$37"N OM IEft IW Iftle Rm*Par&mw
#IriYmm lXd FU16% RI IT Alum.Gtdf Lok over-5 Obagoodftn HVHZ
4Afsiie ties
_ mm 1iF-Tammm E.WaWr_RJE 44%B
QNllbte�-552.Spsf�t's3f/l�+�.ila�e�t!rsieritg,.-3I6.iQ>i� �
@ 5W mr-F SpatbW 3esamperms ! fuIL651 RI AE Alum Gdf lock over 15-32 Plywood R�
dt latfisr�eiia9il�7�3tores €2010 fomtatodf
9 Camukd'ir'm -1 11 Tumd Pamr-Ills
22�L3 1'l�eR�mE laiG1[ I` its.#�F�36r�{,�`�>�flo6€lac 15p/3t'
tFLI651 R1 ff 1 Meeh Lock 24 col over-5 ply HVHZ
vftwnld 1*-- ll:W*AFP-Px_APOW3
7LOp�g2s'c�caffp-,qwKftW-1�5@aF@ Es
r-CRO swadoJ-I%XA per IF I dwwml--.fiar me in a 1 151 RI AF t Mech U)ck 24 ga, over_S Ptgwpw_Z
!llYEtZ 7>vaes Roof 2010 formatadf
23AZIA 8.#1132`lliaims IW Wft Rmt Panel
avrts�
iAppe iac asieiiA>ll x F1.1651_RI H ?in Mech Lock Alm aa_wffss-
Appre�+iirr aloe rrl�iie iA1lr�Mhs VleiHF Te-*Dm a VAtift,PX.44923
CIONOWS FAlM"IftwIV--Y&S
Rll rt � .c]$ - Q#p` 811651 RI 1F 1 Melt L.odc Alum over St Plvwond HVHz
O-C-Clip spallow iia per E 2e6 ldstm-mr.i"ar we is Roof 2010 formatodf
111WIZzoom!r Cinaledby ,-MWMyes
Appmm*
iiMtlWML-V45 F1 I651 111 11 24 go 1,inShap rock over.5 Riywood HVHz
Ii■pt#iaroullftwx ltaiTmeme EWak�P.E.4M
104isigsl�aee 44*1-13.lg c4saei IN 11dwill Flarlies
Oft=-mW-3wFO:Ar— cl0ip spawcarp .@ psf @ s iewamft
a-C-e6g�-B-Rau,NEW smograwswas OWNS lb ie R I11M t AE 1X Snap rock 24 ca over 5 p[vwoW HVHZ
Roo 2Mn formatodf
Cmftd by 'lam ftn%--vm
35
,�
,. - 1' 4 ,. �, 1
r �' 1 1. .� � :' � I
� :� ! J � e� I r �j 1. J �,� rl w q I i c' �1
� 1 t M. A
r x r li l
-�� r �. ' � ;_ -. �
1, f 'N i I� Mt i '. � � 1 h .i � � � ! �
', ` 1 � i .. V x r.
N. _ � 1 �,
i'� i 1 �1 A 1' .1 �:r
�1 �Y 'i. j I � 1 i it � I rt 1'.
I 1 1
+r 1 ,w I y 1 �` ..; t is �� � � ��
;, .r ,r .r rr 1
N � 1 E'`
1 � ,:
r 1 �, y
(' 1 ' i' I� « I� N � =1
� ii ,) 4E
r ; '' r `� � �' +:
1. t M
� � �' �
1
ri
'I �. 1
� 1 ti
., y 1' .i w
� 1'. .1
t, Y
1 -
,` c• 1
r' ..' M� .� rr r' � 1 � t .. a r' * W - � rl * �, r� 1 r� � r� _- r �� MI i .. ■1 x. ■� 1^ /+ rl ly
i` 1. J' 11 Y 1' I' � , i . 1 = li 1 If � r��� �1
,"� � 'r C G � —� � i
�, ♦ t ,� n r r• 1. r.
,� ,, a, ,� t+ � � _ '_ _ �}
�,� � 1� �� I. f 1 r �r �I p .t P. 1� i l' y 1 _
�, � 1` �� r` � n
rr �. r �, 1. 1". -�. I f� 1, 1. l; � �. � � I P �. 1' Yr 1' i +1,
1 1' i, t I L r � � x�.
� 1: r: 1 IA r: 5.
i, � 1'
'� t j' yl r. � r 1
r � ;' � L r. `. �p
► ;, t � h F 1 � 1. li
"�.
ti
�.
641
h
{ � it� f I#� � �P 6 �[S� �P I [g f±5 � �� �I� p �� f►1�� �; � ���;�� � p ., [Ito
a '
fill �
e. o ,
wt
f k �
1
Force En&ejing&Testing Inc.
195oRzmblcwood IMm
Humb&e,TX InM
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC,
26 Ga.5V Crimp Roof Panel over 15I32"Plywood
Florida Product Approval#11651.13 111
Florida Building Code 2010
Per Rule 9N-3
Method:1—[i
Category:Roofing
Subcategory:Metal Roofing
Compliance Method:9N-3.00S(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY&MANUFACTURING,LLC.
4020 S.W.449"Street
Horseshoe Beach,Florida 32649
Engineer Evaluator:
Terrence E.Wolfe,P.E.#44923
Florida Evaluation ANE ID:1920
Validator:
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents-
Evaltiation Report Pages 1—4
tassarat'r,'r
C E xse
50=4F
-6
# Ulu
A
Ass or talks
2D12
Force Engin ejing&Testing Inc.
19SM Piumd4ewood Dsivv
Numble,TX 77339
compliance Stmmm;t: The product as described in this report has demonstrated compliance with the
Rodda Building Code 2010,Sections 1504.31.
Product Description: 5V Crimp Roof Panel,26 Ga. Steel, 24" coverage, through fastened roof panel
with fasteners in the panel flat over Min. 15/32" Plywood decking. Non-
Structural Application.
Panel Material/Standards— Material: Min.26 Ga.Steel,ASTM A792 or ASTM A653 G9.0 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional
Yield Strength: Min.80.0 ksi
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2010,Section 1507-41.
Panel Dimenslon(s): Thickness: 0.018"Min.
Width, 24"Coverage
Rib Height: 3/r major rib
Panel Rollformen Metal Roliforming Systems
Panel Fastener. #9-15 x 1-112" Woodgrip with sealing washing in the flat of the panel or
approved equal,Wminimurn penetration through plywood.
Corrosion Resistance:Per Florida Building Code 2010,Section 1506.6,1507.4.4
Substrate Description: Min.15/320 thick,APA Rated plywood over supports at maximum 24!'O.C.
Design of plywood and ph-wood supports are outside the scope of this
evaluation. Must be designed in accordance w/Florida Building Code 2010.
Deskn Uplilit Pnwsures:
*tIe*PFN� ftdwfta Fatow-211L
-•10,
V C E illse
ago,
z
-4r
Z'
�r.aire his 4r
011AIL
FU 116511.13 21 Feb�gig
Force En&eckng&Testing Inc.
19-S3o AxwUmood Drive
Humble,TX 77338
Codecamphoom The pwductdesaapedhenmhasdonamZ-dl edcmvWkwice*lth
rhe Florida Building Code 2010,Section 1504.3.2.
Evaluation Report Scope.* The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010,as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06-Test for Uplift Resistance of Roof Assemblies
• UL 1997-04-Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94/1897-98 Uplift Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.117-0053T-05&117-0331TM
2. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Test Standard Equivalency. 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Flodda Budding Code and Rule 9N-3.005(3)for
manuftKitift under a quaky assurance program audited by an approved
quality amurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12,lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Underlaymerm Per manufacturet's insmliation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm- Shear diaphragm values are outside the scope of this report.
,%%*%%a glass
C Ifs
SUMEOF :or Z
.4W
0
�102ri -.
A
's
WIP, Oil
stage, 551�1&101
FIJ 11416511-13 R1 FeWUary 22,2012
rv+ 07 Nq �
" w
y e � ► dye 4
aV
CL
o R
W
w.
4.kd.r
+ � .aWtN�FAPnk ,
�\\�MV ^ ,�MrrMPWa4Ylinv.
,�tupr4atx,Y+W
Nrw+r�W
MMl, , OP
SN
ok {yam} �y P•'+"�r'�
YP
y:1e{!,'l..ta"w.AM��Y,NM1r,pM`I Y'�"1\1V,rMMth•� ..
Mme. , JY t
i vy�2 1
aW � SOON
OQ\,f CONS!
0 x;(*' P{
VIC
Its
oil
EB
�� ..
4r28Z015 FlW mft Bt>d6ng Code Online
KORIDA NOW~OF
Business & t l d Atid
Flor da Department ftHrnffi Lag at wg,r or, Hialt 7apts tt -� s fFa>ft Pidlmcws FffC Sftaff Sfk.,Vw u nks
Business
Professitna{ , " "°"a'
W Usm�Pdbbc User
Regulation
Product Aoorov I Menu>Product or Aodication Search>Aoolication List>Appiotion Detai
« •i� fIFL,# FL5259-11122
Applucaltiion Type Revision
Code Version 2010
ApplKaboan Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
» Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/01/2017
Validated By John W. Knezevich, PE
Validation Checklist- Hardcopy Received
Certificate of Independence FL5259 R22 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2001
ASTM D226 2006
ASTM D6164 2005
ASTM D6222 2002
ASTM G154 2005
ASTM G155 2005
httpsl/floridabLilcirg.orgtpr/pr_app M.aspx9Wam=wGEVXQwtDgvbSgWp3Crk2vS%2feg0lipx8OgxmYerJSrrNVv9M9Bbg%3d%3d 1/2
4/282015 Florida Building Code ONine
FM 4474 2004
FRSA/TRI 07320 2005
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/25/2015
Date Validated 02/26/2015
Date Pending FBC Approval 03/02/2015
Date Approved 04/15/2015
Date Revised 04/24/2015
Summary of Products
FL Model Number or Name Description
5259.1 Potyglass Rolf Roofing undelydaymen s
Umdelrl4ymieffts
Lints of Use Lstaillation Instructions
Approved foruse irHVHL-Nlo FL5259 R22 II 2015 02 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
Approved for use outside HVHZ Yes R22.odf
Impact mane-liu//A YerrilFded By:: Raberttt Nie mit elm PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third(Party:Yes
Other-1.)The design pressure in dies Evaluation Reports
application relates to one paiticdar FL5259 R22 AE 2015 02 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
undedayment system(ever cnmorefte deck)IFolr R22.Did
use under foam-on tilde system(where the Created by Independept Third Party-,Yes
underiayment forms part of the load-path)..
Refer to ER Section 5.6.4E far other systems,
other deck types and associated)maxrmern
design pressures.2..)Re ffer tID BR Seatom 5 fferr
other limits of use.
0
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity. Instead,contact the office by phone or by traditional mail. If you have any questions,please contact 850.487.1395. *Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S. must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
WN E
sccurity.m 1.TR ic,
OREM
httpsJ/fforidabLil(Jirg.orgV/pr_app o.asps?pwam=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlipx8OgxmYerJSrrNVv9M9BW/o3d%3d 2/2
EXTERIOR RESEARCH&DESIGN,LLC..
Certificate aAaafionaat;on Jl9503
'�'�/ 353 CHRISTIAN STREET,UNIT#13
s
TRINITY 1 ERD OXFORD,CT 06478
PHONE_)203)262-9245
FAX_(203)262-9243
EVALUATION REPORT
Pow USA,Inc Evaluation Report P12060.02.09-R17
150 Lyon Drive F 5259-R22
Fernley,NV 98408 Date of Issuance:02/24/2009
Revision 17:02/23/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 2010 Florida Building Code sections noted
herein.
Dew=mm: Polyglass Roof Undedayments;
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
:4= The facsimle seal appeanng was authorized
by Robert Nieminen,P-F-on 02/23/2015
Robert J.M.Nieminen,P.E. This does not serve as an elecuonrally signed document.
s
4�'FS'"•• ;- te sealed hardcopies habeen transmitted to the
Florida Regi tmm No.59166,Florida DCA ANE1983 J,; �,v'`
Product Approval Adnanistratu and to the warned diem
CEI FlICATUM OF II1NEWPENDBICIE:
1. Trinity IERD does riot have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates_
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are beteg issued_
4. Robert Nieminen,P.E_does not have,nor will acquire,a financial interest in any other erriity involved in the approval process of the
product.
5. This is a building code evaluration. Neither TrilrtitylERD nor Robert Niernninen,P.E.are,in any way,the Destner of Record for any
project on which this Evaluation Report,or previous very thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFIii1G COMPONENT EvAum ION:
1. SCM:
Product Category: Roofing
SuaCategory: Underlayment
Compliance Statement Roof Undedayments, as produced by Potyglass USA, Inc, have demortstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.3,1507.3.3,1507.5.3,1507.7.3, Physical Properties ASTM D226 2006
1507.8.3,1507.9.3
1507.2.4,1507.2.9.2,1507.3.3,1507.5.3 Physical Properties ASTM D1970 2001
1507.11.2 Physical Properties ASTM D6164 2005
1507.11.2 Physical Properties ASTM D6222 2002
1504.6 Accelerated Weathering ASTM G154 2005
1504.6 Accelerated Weathering ASTM G155 2005
1504.3.1 Wind Uplift FM 4474 2004
1507.3.3 Installation Practice FRSA/TR1 07320 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
90titt Examination Reference Date
FM Approvals(TST 1867) Wind Uplift 3004091 01/12/2000
PRI(TST 5878) Physical Properties PRIO1111 04/08/2002
PRI(TST 5878) Physical Properties PUSA-005-02-01 01/31/2002
PRI(TST 5878) Physical Properties PUSA-013-02-01 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-02 12/23/2002
PRI(TST 5878) Physical Properties PUSA-013-02-03 12/23/2002
PRI(TST 5878) Physical Properties PUSA-018-02-01 07/14/2003
PRI(TST 5878) Physical Properties PUSA-028-02-01 07/13/2005
PRI(TST 5878) Physical Properties PUSA-033-02-01 01/12/2006
PRI(TST 5878) Physical Properties PUSA-035-02-01 09/29/2006
PRI(TST 5878) Physical Properties PUSA-055-02-02 12/10/2007
PRI(TST 5878) Physical Properties PUSA-061-02-02 01/28/2008
PRI(TST 5878) Physical Properties PUSA-076-02-01 02/22/2008
PRI(TST 5878) Physical Properties PUSA-083-02-01 04/14/2008
PRI(TST 5878) Physical Properties PUSA-088-02-01 07/29/2009
MTI(TST 2508) Physical Properties JX201-17A 04/01/2008
MTI(TST 2508) Physical Properties RX14E8A 01/29/2009
ERD(TST 6049) Physical Properties 11752.09.99-1 02/08/2000
ERD(TST 6049) Wind Uplift 11757.08.01-1 08/13/2001
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003
ERD(TST 6049) Physical Properties 02200.07.03 07/14/2003
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007
ERD(TST 6049) Physical Properties P5110.04.07-1 04/11/2007
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008
ERD(TST 6049) Physical Properties P13450.08.09 08/13/2009
ERD(TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-1 11/30/2009
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009
ERD(TST 6049) Physical Properties P11030.11.09-3 11/30/2009
ERD(TST 6049) Physical Properties P33360.06.10 06/25/2010
ERD(TST 6049) Physical Properties P33370.03.11 03/02/2011
ERD(TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD(TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD(TST 6049) Physical Properties C41420.09.12-3 09/11/2012
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1137
Certificate ofAuthoriration#9503 FL5259-R22
Revision 17:02/23/2015
Page 2 of 11
i
TRINITY"ERD
Erdft 6mudinatioe Reference oohs
ERD(BST 6049) Wimd tUOiiff P3969MM.13
0W kTST U ft"94 Rapeamies F1 n3M"1J3 04t2fiAM3
ERD(TST 6049) Windupw P1738.02.(Y7-R2 04/29/2013
ERD(TST 6049) Vdkd u pw t 11757.04.01-14R1 04/30/2013
ERD(d5T 6049) Wimdl upaift P41630.0613 08/06/2013
ERD M G9) WMd U011flt P11751-G52341 1X26/2013
ERD(TST 6049) Wod Upbllt P117BLIL03-R1 11/26/2013
ERD(AST 6049) Physicall Prope — P45270-05.14 05/12/2014
ERD(AST 6049) PlrysitA Peoperti«. 07.14-1 09/08/2014
ERD(M x' Pl pkcaII Rioperbes 6020..09-14-2 09/043/2014
ERD(TST 6049) Physical Properties 6020-09.14-3 09/08/2014
ERD(TST 6049) Physical Properties 6020.09-14-4 09/08/2014
ERD(TST 6049) Physical Properties 6020-09.14-5 09/08/2014
ERD(BST 6049) PhV-9 Properties 6020.09.14-6 09/08/2014
ERD(AST 6049) Physical Properrties P46520.10.14 10/03/2014
ERD USB 6049) Physical Properfies P44360_10.14 10/07/2014
ERD(AST 6049) Physical Properties P43290.10-14 10/17/2014
ERD(AST 6049) Phyvsll 11'7oper t- PILVCi 5C75%14 11/25/2014
KC-ES(EVIL 2396) IBC Compliance ESR-1697 11/01/2014
Miami-Dade(CER 1592) HVHZ Cornpiance NOA 14-0717M 01/22/2015
Polyglass USA Manufacturing AWKIlavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571,2QA Exp.08/08/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation,MTS PLUS Exp.07/01/2017
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlavments:
4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet.
4.2 Self-Adhering Underlavments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface;meets ASTM D1970 and TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly-film surface;meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface;meets ASTM D1970.
4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane,glass fiber reinforced,with a
polyester fabric surface;meets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,glass-fiber/polyester reinforced,
with a granular surface;meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface;meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) are polyester
reinforced,APP modified bitumen cap sheets;meet ASTM D6222.
4.2.8 Polystick Dual Pro- is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970.
4.2.9 Polystick Tile PrOTI is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass
reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.3 Mechanically Fastened and/or Bonded Underlavments:
4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen Cap sheets;meet ASTM D6222.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R37
Certificate of Authorization#9503 FL5259-R22
Revision 17:02/23/2015
Page 3 of 11
i
TRIN-ry ERD
6.4.4 Two(2)Ply U ayrnent ..
6.4.4.1 Polystick MTS or MTS PLUS followed by Polystick MTS,TU P,TU Plus,TU Max,TilePro or Polyflex SAP is allowable for
use under mechanically attached prepared roof systems. Limits of use are those associated with the top-layer
material. This is not a requirement,but is allowable if a 2-ply underlayment system is desired.
6.4.4.2 Polystick MTS PLUS followed by Polystick TU P,TU Plus,TU Max,TilePro or Polyflex SAP is allowable for use under
foam-on tile systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition,and Table
2 herein.
6.5.2 Elastoflex S6 G or S6 G FR shall be fully asphalt-applied to the substrates noted in Section 5.5. Side laps shall be
minimum 3-inch and end-laps minimum 6-inch wide, and off set end-laps minimum 3 feet from course to course.
Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately
3/8-inch beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications,reference is made FRSA/TRI 07320/8-05 Installation Manual,Fourth Edition,and Table 2 herein.
6.6.2 Polyflex G or G FR shall be fully torch-applied to the substrates noted in Section 5.5. Side laps shall be minimum 3-
inch and end-laps minimum 6-inch wide,and off set end-laps minimum 3 feet from course to course. Side and end
laps shall be fully heat-welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the
lap edge.
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter-battens, as required by the tile manufacturer and FRSA/TRI 07320/8-05 must be used on all
roof slopes greater than 7:12. Precautions should be taken as needed,such as the use of battens or nail-boards,to
prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.7.4 For nail-on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged the regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-
eight(48)hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 1312060.02.09-1117
Certificate of Authorization#9503 FLS259•1122
Revision 17:02/2312015
Page 11 of 11
TRINITY ERD
S. LwiffATum:
5.1 This is a bum code evaluation- fleitlhm Tdnity)ERD nor Robert Nierninen, P-E_are,in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
Tma L-Row Cava OmoNs
neaAhk Onle rwOn liaWood SieeDdeveet Wa
Eastohase I
Yes res Ppo lies res res
Elastobase P Yes Yes No Yes Yes Yes
Polystick MTS Yes Yes No Yes Yes Yes
Polystick MTS PLUS Yes Yes No Yes Yes Yes
4dysSickYR-Xe Yes 440 440 440 Yes `Ses
Polystick TU P ! Yes Yes Yes No Yes Yes
See 5.5.1
i
Polystick TU Plus I Yes Yes Yes Yes Yes Yes
See 5.5.1
Polystick TU Max No Yes Yes Yes No No
See 5.5.1
Polystick Dual Pro ! Yes Yes No Yes Yes Yes
�l 4o4rsSickTiie4ro I Y� Ves Yes es
See 5.5.1
I Elastoflex S6 G Yes Yes Yes No Yes Yes
See 5.5.1
Elastoflex S6 G FR Yes Yes No No Yes Yes
rp'o
lyflex G Yes Yes Yes No Yes Yes
See 5.5.1
Polyflex G FR Yes Yes No No Yes Yes
Yes
Polyflex SAP or SAP FR ' Yes Yes See 551 No Yes Yes
Mule4 ide SA-APP Cap Sheet or SA- Yes res Yes No res Yes
APP Carp Sheet(FR) See S-5-1
5.5.1 'Foam-On Tile"is limited to use of the following Approved file adhesives unless tensile adhesion/long term aging data
from an accredited testing laboratory is provided.
✓ 3M—2-Component Roof Tae Adhesive AH-160&nne►y PbWbon PbtyProAH16ar Polystick TU P,Polystick TU Plus,
Polysfi&TU Max, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,Mule-Hide SA-APP Cap Sheet or
Mule-Hide SA-APP Cap Sheet(FR)or Tile Pro.
✓ 3M—Foam Roof Tli a Adhesive RTA-1: Polystick TU P,Polystick TU Plus,Polystick TU Max,Elastoflex S6 G,Polyflex
G,Polyflex SAP,Polyfleit SA Cap FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)or Tile Pro
✓ Dow TAeBond: Polystick TU P,Polys"TU Plus,Polyflex SAP or Tile Pro
✓ Convenience Prod ucte Touch In Seal StormBond Roof Tae Adhesive: Pock TU Plus,Polystick TU Max
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R17
Certificate of Authorirotion#9503 FL5259-R22
Revision 17:02/23/2015
Page 4 of 11
TRINITY ERD
5.6 Alllowable Substrates:
5.6..1 Diirea-BondttoDeck.
Polystick(all variations), Dual Pro,Tile Pro, Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR)self-adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern
Yellow Pine;ASTM D41 primed structural concrete;Huber Engineered Woods"ZIP System"Panels(designed and installed
to meet wind loads for project).
Note:Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB
sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch-applied to:
➢ ASTM D41 primed structural concrete.
5.6.2 Bond-to-Insulation:
Polystick,Polyflex SAP or SAP FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)self-adhered to:
➢ ASTM C1289,Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard;
Dens Deck Prime;or SECUROCK Gypsum-Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
Polyflex G or G FR torch-applied to:
➢ ASTM D41 primed structural concrete;Dens Deck Prime or SECUROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FM 4470,Appendix K or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self-
adhered to:
➢ ASTM D226,Type I or 11 felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D226,Type I or 11 felt;Elastobase;Elastobase P or Mule-Hide Nail Base.
Polyflex G or G FR torch-applied to:
➢ Elastobase;Elastobase P or Mule-Hide Nail Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam-on the systems, refer to Section 5.5.4 herein and FRSA/TRI
07320/8-05 or RAS 120.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R37
Certificate of Authorization#9503 FL5259-R22
Revision 17:02/23/2015
Page 5 of 11
i
TRINITY ERD
5.6.4 Wind Resistance for Underlayment Systems in Foam-0n Tile Applications FRSAITRI 07320 does not address wind
upift resistance of all undedayment systems beneath foam on the systems„where the underlayment forms part of the
load-path. The following wind uplift Yimitations apply to undedayment systems that are not addressed in FRSA/TRI
07320 and are used in foam-0n the applications. Maximum Design Pressure is the result of testing for wind load
resistance based on allowable wind bads Refer to FBC 16091.5 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.2 Maximum Design Pressure=-135 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.3 Maximum Design Pressure=-315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Polystick TU P,Polystick TU Plus,Polystick TU Max,Tile Pro,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap
Sheet and Mule-Hide SA-APP Cap Sheet(FR),self-adhered.
5.6.4.4 Maximum Design Pressure=-622.5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.5 Maximum Design Pressure=-30.0 psf.
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase or Mule-Hide Nail Base(poly-film top surface)mechanically attached with 11 ga.x 1.25-inch long x f-
inch head diameter round metal cap nails spaced 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)
equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.6 Maximum Design Pressure=-37.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase or Mule-Hide Nail Base(poly-film top surface)mechanically attached with 11 ga.x 1.25-inch long x f-
inch head diameter round metal cap nails spaced 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)
equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.7 Maximum Design Pressure=-37.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: One(1)or two(2)layers ASTM D226,Type II felt mechanically attached with 11 ga.x 1.25-inch long x 1-inch head
diameter round metal cap nails spaced 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally
spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt.
5.6.4.8 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: One (1) layer ASTM D226, Type II felt mechanically attached with 11 ga. x 1.25-inch x 3/8-inch head diameter
annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 4-inch o.c.at the 2-inch wide side laps and
4-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.9 Maximum Design Pressure=-45 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Two(2)layers ASTM D226,Type It felt mechanically attached with 11 ga.x 1.25-inch long x 3/8-inch head diameter
annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 9-inch o.c.at the 2-inch wide side laps and
9-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,PolyFlex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-1137
Certificate of Authorization#9503 FL5259-R22
Revision 17:02/23/2015
Page 6 of 11
t TRINITYERD
5.6.4.10 Maxiunuin Design Pressure=-45�f..
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 9-inch o.c.at the 2-inch wide side laps and 18-inch
o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.11 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 9-inch o.c.at the 2-inch wide side laps and 12-inch
o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.12 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase or Mule-Hide Nail Base (poly-film top surface) mechanically attached with Simplex Original Cap Nails
spaced 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.13 Maximum Design Pressure=-52.5 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with Simplex Original Cap Nails spaced 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.
at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.14 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-
5/8-inch diameter tin caps spaced 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at three(3)equally spaced
staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.15 Maximum Design Pressure=-60 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates spaced 12-inch o.c.at
the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.16 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 6-inch o.c.at the 2-inch wide side laps and 6-inch
o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.17 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates
or OMG Flat Bottom Metal Plates spaced 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally
spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.18 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase(sanded top surface)mechanically attached with Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal
Insulation Plates spaced 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c,at three(3)equally spaced staggered
center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
Exterior Research and Design,I.I.C. Evaluation Report P12060.02.09-R37
Certificate of Authorizotion#9503 FL5259-R22
Revision 17:02/23/2015
Page 7 of 11
TRINITY ERD
5-6.4-19 Mainirnrmr Design EMU"=-97-5 .
4'Dedlc Ulm 19132-finch*wood to meet pmyect requiit-n-ms to satislactiarm of U-
Base LT#er EIasWilaseor n dlr-IHNde DillBasel(PmjOikm topw.4aellnNKhaNxcai4aa3dyedmith 11 g x 1-25-w h x 3/8-woch diameter annular ring shank roofing nads at 1-5/8 ondh d ianwter tin caps spaced 4-iinc h o.c_at the flinch wide
side Gaps and 4-inch ox-at four 14)equally spaced stared center rows.
Unde dayvnent Pa"xk TU P,Po4sb*TU Pias,.Poly lex SAP.PoKlmr SHIP FR,Mule-Hide SP1-APP Cap Sheet and Mu"ide SA-APP
Cap 9met
5.6.4-20 Maximum Design Pressure=-105 psf-
Deck Mete 15/32-lurch plywood to rneet project requaremarts to satisfaction of AHG.
Base Layer- Elastobase(sanded top surface for hot-asphalt or torch-applied cap orpoly film surface for torch-applied cap)
mechanically attached with Simplex MAXX Cap Fasteners spaced 6-inch o.c.at the 2-inch wide side laps and 6-inch
o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.21 Maximum Design Pressure=-112.5 psf.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase or Mule-Hide Nail Base(poly-film top surface)mechanically attached with 11 ga.x 1.25-inch x 3/8-inch
head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps spaced 6-inch o.c.at the 4-inch wide
side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Underlayment: Polystick TU P,Polystick TU Plus,Polyflex SAP,PolyFlex SAP FR,Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP
Cap Sheet(FR),self-adhered.
5.6.4.22 Maximum Design Pressure=-120 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase (sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
mechanically attached with OMG#12 Standard Roofgrip or CMG#14 Heavy Duty with OMG 3"Round Metal Plates
or OMG Flat Bottom Metal Plates spaced 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally
spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
5.6.4.23 Maximum Design Pressure=-120 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Layer: Elastobase(sanded top surface)mechanically attached with Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal
Insulation Plates spaced 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered
center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
5.6.4.24 All other direct-deck,adhered Polyglass underlayment systems beneath foam-on tile systems carry a Maximum Design
Pressure of-45 psf.
5.7 Exposure Limitations:
5.7.1 Elastobase or Elastobase P shall not be left exposed for longer than 30-days after installation.
5.7.2 Polystick IR-Xe shall not be left exposed for longer than 90-days after installation.
5.7.3 Polystick MTS,MTS PLUS,TU P,TU Plus,TU Max,Dual Pro or Tile Pro shall not be left exposed for longer than 180-days
after installation.
5.7.4 Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive-set tile, in which case the maximum exposure is 30
days.
5.7.5 Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
days.
Exterior Research and Design,LLC. Evaluation Report P12060.02.09-R37
Certificate of Authorization#9503 FL5259-1122
Revision 17:02/23/2015
Page 8 of 11
TRINITY ERD
5.8 For We roof installations gotlerned by the FRSA M 07320/805 anstallriWn Lim".Fourth Edition,use is limited to
the fallowing.. Reference is wade to the FRSA M Technical Brief tided'Flodda "ith Wind Roof Tile Self-Adhered
Underlayment Requirements as of 02114/'20117 for limitations for self-adhering underpayments used beneath the roof
-
systems
Tmu2:TntSmmOnonpmFRSWM07 /1.06
{irderlin
1 r 01 " 1, setbow Retitarae 1
i
n � m�rti�q � €ar°s>�n �E amvxvrt�sst�6�rQp �s��rR;a�yA��m���
,! 'pta:>tdbase,£lasizlbase
System One; 2 3.028 No,301 Modified Cap Sheet 'Base tayer:
Top Layer:Elastoflex S6 G or Elastoflex 56 G FR;Polyflex G or G FR
Tile,Unsealed or
Mechanically Fastened 4 3.02D No.30 Elastobase;Elastobase P
Seated UnderlaymentS 3.02E Self-Adhered Underlayment Polystick MTS;MTS PLUS;TU P;TU Plus;TU Max;Polyflex SAP or SAP FR;Mule-
System Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR);Dual Pro;Tile Pro
No.30/Self.Adhered Base Layer:ASTM D226,Type 11;Elastobase;Elastobase P;Mute-Hide Nail Base
6 3.02F Underlayment Top Layer:Polystick MTS;MTS PLUS;TU P;TU Pius;TU Max;Polyflex SAP or SAP
FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR);Dual Pro;Tile Pro
a 3.02A Modffied Cap Sheet Elastoflex 56 G or Elastoflex S6 G FR;Polyflex G or G FR
Batten only
System Twa: 2 3028 No.30/Modified Cap Sheet Base Layer:Elastobase;Elastobase P
Mechanically fastened Top Layer;Elastoflex 56 G or Elastoflex S6 G FR;Polyflex G or G FR
Tile,Sealed 4 3.02D Self-Adhered Underlayment Polystick TU P;TU Plus;TU Max;Polyflex SAP or SAP FR;Mule-Hide SA-APP Cap
Underlayment System Sheet or SA-APP Cap Sheet(FR);Dual Pro;Tile Pro
No.30/Self-Adhered Base tater:ASTM D226,Type N;8astc base;Elastobase P;Muk-Nide Nail Base
5 302E Underlayment Top Layer:Polystick TU P;TU Plus;TU Max;Polyflex SAP or SAP FR,Mule-Hide
SA-APP Cap Sheet or SA-APP Cap Sheet(FR)Dual Pro;Tile Pro
I 3.02A Modred Cap Sheet Elastoflex S6 G or Polyflex G
2 3.028 No,301 Modified Cap Sheet Base Layer:Elastobase;Elastobase P
System Four"A": Top Layer:Elastoflex S6 G or Potyflex G
Adhesive-Set Tile, Polystick TU P;TU Plus;TU Max;Polyflex SAP or SAP FR;Tile Pro;Mule-Hide 5A-
Unseated or Sealed 4 3.026 Self-Adhered Underlayment APP Cap Sheet or SA-APP Cap Sheet(FR)
Underlayment System
5 3.02E No.34 j Self-Adhered Base Layer:ASTM D226,Type 11;Elastobase;Elastobase P;Mule-Hide Nail Base
Underlayment Top Layer:Polystick TU P;TU Plus;TU Max;Polyflex SAP or SAP FR;Tile Pro;
Mute-Nide SA-APP Cap Sheet or SA-APP Cap Sheet{fft}
1 3.020 Na.34 j Modified Cap Sheet Base Layer:ASTM D226,Type Il;Elastobase;Elastobase P
Top Layer:Elastoflex S6 G or Polyflex G
System four"8":
Adhesive-Set Tile, 3 3.02C Self-Adhered Underlayment Polystick TU P;TU Plus;TU Max;Polyflex SAP or SAP FR;Tile Pro;Mule-Hide SA-
Sealed Undertayme+R APP Cap Sheet or SA-APP Cap Sheet(FR)
System Wm 30/SeffiAdhered Base layer:ASTM D226,Type If;Elastobase:Elastobase P;Mute-Nide Nail Base
s IWD larRAeft Top Layer Pdysw*To P;Ty Pfusi TU Mac PoWilex SAP or SAP rit;rde Pro;
Mun"We S&,W cap street or sA-APP tap Sheet 1011)
6. tlKTAttmm:
6.1 Polyglass Roof Underlayrnents shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics rioted below.
6.2 Re-fasten any loose denting panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
63 Elastobalse,Elastobase P or Mule-Fide Nal Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASPM D226,Type II undedayment in FBC Sections
1,507 for the type of prepared roof covering to be installed.
6.3-2 For use in non-tile applir:attions:
6.3.2.1 Reference is made to the current edition of the NRCA Stee"ope Roofing Manual and ARMA recommendations for
installing shingle u nderlayrnents and flashings
6.3.2.2 Elastobase,Elastobase P or Mule4iide Nail Base may be covered with a layer of Polystcli, Polyflex SAP or SAP FR,
Mute-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(Flt),Dual Pro or Tile Pro,self-adhered,Elastoflex S6 G or S6 G FR
in hot asphalt or Polyflex G or G FR,torch applied.
633 For use in file applications, reference is made to Polyglass published installation instructions in conjunction with
FRSAt Rl 07320/8-05 Installation Manual,Fourth Ed itiort,Table 2 herein and Section SSA herein.
Exterior Reliourh aid DesiM tdL Evalmatiort Report P12060A2.09-R17
C of rmiroOau tF R5259-M
RewWon 17:OnW2015
Page 9 of 11
TRINITY ERD
6A Pok-Ock NRS.Mn PLUS,IR-Xe.TU P TU Plus,TU Max PoWWx SAP or SAP FTI.Mule-Fide SA-APP Cap Sheet or SA-
APP Cap Sheet(FRL Dual Pro or Tie Pro-
6-4.1 Shag be installed in compliance with the codified requirements for ASTM D1970 underlayrnent in FBC Sections 1507
for the type of prepared roof covering to be installed.
6A.2For non-dile appl6cationsz.
6.4.2.1 All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAP or SAP FR and Mule-Hide SA-APP Cap
Sheet or SA APP Cap Sheet(FR)should be back-nailed in selvage edge seam in accordance with Polyglass/Mule-Hide
Back Naading Guide- Mails shag be corrosion resistant, 11 gauge ring-shank type with a minimum 1-inch diameter
metali diisNc or Sfmmpllex-type mmeltall cap mraii4,at a mniirrimmuum rate of Ir o-c- Pork lrU Plkus Owuld be back-miled
using the above noted fasteners and spacing,in area marked'nail area,area para davar'on the face of membrane.
The head lap membrane is to cover the area being back-nailed
6-4.2-2 All seal-lap seams(selvage laps) must be fiwn* i
rolled with a minimum 28 Ib- hand roger to
ensure full contact and adhesion. rte'
For Dual Pro and Tile Pro,align the edge of the
top sheet to the end of the glue pattern (the
sheet will overlap the fabric)-
View of Orelap Seam of Dail Pro amd Tie Pro
6.4.2.3 All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer of Polyglass Polyplus 55 Premium
Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Polystick TU Plus Tile Underlayment Flashing Cement, Mule-Hide 241 Premium Modified Flashing Cement,
Mule-Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule-Hide 421 Mod Bit Flashing Adhesive
Trowel Grade mastic,applied in between the application of the lap.
6.4.2.4 Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such as crickets,exposed valleys,
or exposed roof to wall details
6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing
Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass PG500 MB Flashing Cement,Polystick TU Plus
Tile Underlayment Flashing Cement, Mule-Hide 241 Premium Modified Flashing Cement, Mule-Hide 251 Premium
Wet/Dry Elastomeric Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area
in need of repair,followed by a minimum 6 x 6 inch patch of the Polystick material of like kind,set and hand rolled in
place over the repair area. Patch laps,if needed,shall be installed in a water shedding manner.
6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-Ib weighted-roller or,on steep slopes,use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps(min. 28 Ib roller)or small areas of
the roof that are not accessible to a large roller or broom.
6.4.3 For tile applications(not allowed for Polystick 1R-Xe):
6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition,Table 2 herein and Section 5.5.4 herein,using the instructions noted above as a guideline.
6.4.3.2 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile.
6.4.3.3 For nail-on tile systems over Polystick MTS PLUS:
Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
Exterior Research and Design,I.I.C. Evaluation Report P32060.02.09-1137
Certificate ofAuthorizotion#9503 FL5259-R22
Revision 17:02/23/2015
Page 30 of 11