Loading...
HomeMy WebLinkAboutEngineering PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 ILE COPY Email pwelchinc@aol.com C 1 ,73 May 7,2015 Re: Brumund Re-Roof 10725 S. Ocean Drive Lot 205 Jensen Beach,FL 34957 SCOPE OF WORK-. Remove existing roofing and install new 5-V Crimp Metal Roof(Gulf Coast Supply& Manufacturing FL# 11651.13)at above referenced residence address over new underlayment and existing plywood sheathing (Flat Roof Not Included) DESIGN CRrrERL4: FBC 2010 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=9'-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE ADJUSTMENT FACTOR= 1.00 RVIPROTANCE FACTOR= 1.00 WIND VELOCITY V uit= 165 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=D ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (y ZONE I (Field)=-44.7 ZONE 2 (Perimeter/Ridge)=-75.5 ZONE 3 (Comers) -110.8 Paul Welch Inc. Paul Welch P.E. Reg.No. 29945 May 7,2015 10725 S.Ocean Drive Lot 205 Jensen Beach,FL 34957 11-1 1 of ATTACHMENT REQUIREMENTS: Metal roofing to be attached with#9-15 x 1 1/Z"long(minimum 1/4"penetration through plywood sheathing)Woodgrip screws with weather sealing washers spacing as follows: ALL FASTENERS IN THE FLAT OF THE PANEL ZONE I (Field): Fasteners adjacent to ribs one side(Type 1 per product approval)at 16"O.C. ZONE 2(Perimeter/Ridge): Fasteners adjacent to ribs one side(Type 1 per product approval)at 16"O.C. ZONE 3(Corners): Fasteners adjacent to ribs both side(Type 2 per product approval)at 16"O.C. Zones 1 &2 Design uplift Pressure: -94.25 psf Zone 3 Design uplift Pressure: - 13 1.0 psf Zones 1 &2: 94.25 >75.5 >44.7 Therefore O.K. Zone 3: 131.0> 110.8 Therefore O.K. UNDERLAYMENT• Underlayment shall be Polyglass USA, Inc. FL# 5259.1 "Polystick TU Plus". Polystick TU Plus shall be installed in compliance with the codified requirements for ASTM D 1970 underlayment in FBC Section 1507. All seal-lap seams must be firmly rolled with a minimum 281b. hand roller to ensure full contact and adhesion. DECK INSTALLATION: Re-nail all plywood sheathing(19/32"thick minimum)with 8D ring-shank nails at 4"O.C. perimeter and 6"O.C. field for all zones. All work to be in compliance with product approval (FL# 11651.13),(FL# 5259.1), manufacturer's specifications,and the Florida Building Code 2010. Paul Welch Inc. Paul Welch P.E. Reg.No. 29945 May 7,2015 10725 S.Ocean Drive Lot 205 Jensen Beach,FL 34957 2 of 3 .... ........ .. _ pi j f j N �+I It !. V f `O 1 it Oil I 1 i �� �•j j�j ! I. {' j d a �ti ROOF ZONE PLAN A=3' 1Q,02 ,03 = ZONE DESIGNATTON(TYPICAL) Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 7, 2015 10725 S.Ocean Drive Lot 205 Jensen Beach,FL 34957 � 3 of 3