Loading...
HomeMy WebLinkAboutEngineering r i c — j REV. a NO P.E. SEAL REQUIRED REwSIONS: EWSED BY DATE MODEL DESIGNATION: Simonton Awning Series 08-20 Vinyl Impact Window 1 UPDATED ANCHORS PER NEW TEsnac. T.D.D. 05/11/11 MAXIMUM OVERALL NOMINAL SIZE: Single up to 53" x 28" INSTALLATION SUPPORTED 2 UPDATED ANCHORS PER TESTING. T.D.D. 09/19/11 DESIGN PRESSURE RATING: Positive: 55.0 PSF BY AAMA TEST REPORTS 3 ADDED NOTE 10. T.D.O. 01/09/12 Negative: 55.0 PSF USABLE CONFIGURATIONS: X GENERAL DESCRIPTION: The head, sill, and side Jambe are extruded PVC. The wall thickness SILICONE CAULK through which the anchor screw penetrates is a minimum of 0.070". 1/8" X 1 1/2" MIN. ROOFING NAIL WITH 1" MIN. 2X BUCK EMBEDMENT INTO WOOD, 3/8" MIN. FROM WOOD EDGE 1/4" MAX. SHIM #8 X 2 1/2" WOOD SCREW THROUGH EACH (2) N8 X 2 1/2" WOOD HOLE OF IMPACT SNUBBER SCREWS AT EACH IMPACT SNUBBER HEAD 2"—+I— I—�MAX.OTYP.ff 2"--��— 4X SCALE SCREW THROUGH EACH 2X BUCK #8 X 2 1/2" WOOD SCREW TIE BAR GUIDE THROUGH SECOND AND FOURTH a I 1/ JHOLES AMBS) 4" MAX. SHIM F I F HINGE TRACK (BOTH"---I #8 X 2 1/2" WOOD SCREW THROUGH x I I X SECOND AND FOURTH HOLES OF co I (1) #8 X 3" WOOD SCREW I co a HINGE TRACK (BOTH JAMBS) 0 W THROUGH EACH TIE BAR W 1 3 GUIDE (BOTH JAMBS) i 1/8" X 1 1/2" MIN. ROOFING I I NAIL WITH 1" MIN. N j j 3/8"EMBEDMENTM N. FROM WOOD INTOWOODEDGE 3e 2 i SILICONE CAULK L-I I aI JAMB X. SHIM 4XSCALE L------------------ — — ------------------J 1/8" X 1 1/2" MIN. ROOFING t NAIL WITH 1" MIN. 2X BUCK EMBEDMENTINTO WOOD, 53" MAX. OVERALL FRAME WIDTH 3/8" MIN. FROM WOOD EDGE SILICONE CAULK4L1/4" k8 X 2 1/2" MIN. WOOD SCREW WITH 1.50" MIN, EMBEDMENTINTO WOOD SILL 4X SCALE DISCLOSURE STATEMENT SIMONTONe B IN0519 3' This document Is the Property of Simonton Windows,which Dimenslonal Tolerances ratolns all Proprietary and other rights to its subject matter. Unless Otherwise Sneeined W I N u o W s T0.O. 04/12/11 This document 1.proNded to the recipient on the expressed c I Cochrane Avenue CHECKED BY:DATE dltl-that It Is not to be disclosed,reproduced In whole or Pennsbom,WV 26415 part,nor used In conjunction with the dealoon,manufacture or Decimcl. Angles reeppair of goods for on a other then SMonton Windows SCALE: SHEET: APPR 0 BY:DATE vithcut Its consent. This restriction does not Omit the x*.03 MT 1 of 2 reciplent's right.to utilize information contained in this RFACE��' xx ZE 01 0' 30 mtn. SERIES: document which I.property obtained from another source. NIS .XXx*.005 08-20 AWNING IMPACT WINDOW nnE FILE:ING519 2X SUCH INSTALLATION AS TESTED) c� ti REV. REVISIONS: REVISED BY DATE r• MODEL DESIGNATION: Simonton Awning Series 08-20 Vinyl Impact Window 1 UPDATED ANCHORS PER NEW TESTING. T.D.D. 03/11/11 MAXIMUM OVERALL NOMINAL SIZE: Single up to 53" x 28" 2 UPDATED ANCHORS PER TESTING. T.D.D. 09/19/11 DESIGN PRESSURE RATING: Positive: 55.0 PSF 3 ADDED NOTE 10. T.D.D. 01/09/12 Negative: 55.0 PSF USABLE CONFIGURATIONS: X GENERAL DESCRIPTION: The head, sill, and side jambs are extruded PVC. The wall thickness through which the anchor screw penetrates is a minimum of 0.070". NOTES: 1. This installation has been evaluated for use in locations adhering to the Florida Building Code and where design pressure requirements as determined by ASCE 7 Minimum Design Loads for Buildings and Other Structures do not exceed the design pressure ratings listed herein. 2. All exterior perimeter surfaces of the window must be caulked. Interior caluking is optional unless noted otherwise. 3. Anchors shall be specified and spaced as shown. Anchor embedment Into base' SPACER material shall be beyond wall dressing or stucco and into wood. 4. Wood bucks (by others) must be engineered and anchored properly to transfer n EXTERIOR loads to the structure. L 1/8" TEMPERED S. The responsibility for selection of Simonton products to meet any applicable local AIR SPACE lows, building codes, ordinances, or other safety requirements rests solely with the architect, building owner, or contractor. 1/8" ANNEALED 6. Shims are optional. Max. shim stack is 1/4". .090" PVB (SOLUTiA) 7. Screws must be o minimum of 3/4" from the edge of the wood. B. When used in areas requiring Impact protection, this product DOES NOT REQUIRE O 1/8" ANNEALED the use of Impact resistant shutters or other external protection. 9. Flashing should be applied using the ASTM E 2112 methodology appropriate for GLAZING COMPOUND (PECORA 896—HIS) the opening Into which the window is being installed. 10. This product complies with ASTM E 1300-04. 0.500" GLASS SITE INTERIOR 1" INSULATED TEMPERED/ANNEALED IMPACT GLASS WITH 0.090' PVB INTERLAYER DISCLOSURE STATEMENT SIMON TONe B• IN0519 3• Thle document Ie the property of Simonton window.,whloh Dimensional Tolerances `,(/ • retatrle all proprietary and other rights to Its subject matter. Lrnlees Otherwise SpenlRed w ry u o w s T.O.D. 04/12/11 This dawment le proWded to the reelplent m the eepromed 1 Cochrane Avrnue EC NI BY:DATE: ditlon that It is not to be disclosed,reproduced N whole or Pennsbom,WV 26, port,nor used In conjunction with the design,manufacture or Decimals Angles repair of goods for on a othw than Simonton Windows SCAlE SHEET APPR D BY:DATE - re Ito consent. Thin raetrlcti n does not limit the RFACE AREA: X d:.03 FlT 2 of 2 reciplent's rights to ut0lze Information contained in this XX d: 01 0' 30 min. SERIES: damment which Is properly obtained from another source. NI TM T; •XXX t.003 TITLE. 08-20 AWNING IMPACT WINDOW FILE:IN0519 NOTES k GLAZING DETAILS A s