Loading...
HomeMy WebLinkAboutProduct Approval tK e • 9 � 8 e — � e � - �, flaiFB i3Ttl?leiit BCIS Home Log In j User Registration Hot Topics i Submit Surcharge Stats&Facts ! Publications FBC15tarf SCIS Site Map ! Lima Search UuJt1 tcJ � ) D54, Product Approval ProfESSI , g USER:Public User Regulation Product Approval Menu>Product or Aootication Search>Appli[atipn List>Appiicatian Detail f ii►iYiiYilil�i�iLliY4a � � n� FL# �FL5259-R22; Application Type Revision Code Version 2010 Application Status Approved Comments F11 'IE CVPY Archived Product Manufacturer iPOLYGLASS Al cL-? "' � 5u Address/Phone/Email 150 Lyon Drive Fernley,NV 89408 I (570)384-1230 Ext 242 } jakins@polyglass.com Authorized Signature James Akins jakins@poiyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley,NV 98408 (602)363-7139 stevew@polyglass.com i Quality Assurance Representative James Akins Address/Phone/Email 555 Oakridge Road Humboldt Industrial Pkwy Hazleton,PA 18201 (800) 894-4563 jakins@polyglass.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer r. Evaluation Report-Hardcopy R�Iceived ii Florida Engineer or Architect Name who developed ped the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC i Quality Assurance Contract Expiration Date 07/01/2017 Validated By John W.Knezevich,PE J- Validation Checklist-Hardcopy Receilved Certificate of Independence FL5259 R22 COI 2015 01 COI Nieminen.Odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D6164 ' 2005 ASTM D6222 2002 ASTM G154 2005 ASTM G155 2005 FM 4474 j 2004 FRSA/TRI 07320, i 2005 TAS 103 ii 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/25/2015 Date Validated 02/26/2015 Date Pending EBG Approval 03/02/2015 Date Approved 04/15/2015 Summary of Products FL# Model,Number or Name Description 5259.1 (P0_Fyj_1_aii_R66f lin�aflayrr!e�ntsl Limits.of Use Installation Instructions II Approved for use in HVHZ.No FL5259 R22 11 2015 02 FINAL ER POLY61-ASS UNDERLAYMENTS FL5259- Approved for use outside HVHZ:Yes R22. df Impact Resistant:N/A Verified By:Robert Nieminen PE-59166 Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes Other.1.)The design pressure in this Evaluation Reports 11 application relates to one particular FL5259 R22 AE 2015 02 FINAL ER PbLT.LAtQ UNDE LAYMENTS FL5259- underlayment system(over concrete deck)for R2,2.odf 11 i use under foam-on tile systems(where the Created by Independent Third Party:Yes underlayment forms part of the load-path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures.2.)Refer to ER.Section 5 for other limits of use. contact us 3,940 North Monroe Street.Tallahassee-FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.-.*Privacy Statement ::Refund Statement Under Florida law,email addresses are Public records.If you do not want your e-mail address released in response!111 a public-records request,do not send electronic mail!to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,pleasel'contact 850.487.1395.*Pursuant to Section 45S.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide th6 Depiarbment with an email address if they have one.The entails provided may be used for official communication with the licensee.However email addresses are pufl)ic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click here. Product Approval Accepts: NEW FM P9 sec u ri ty m i-,.Ti"c.,: CA I Ent R RESEARCH&DESIGN,LLC. 'Certificate of Authorization#9503 CHRISTIAN STREET,urar#13 ,"-,] TRINITY 353 ERD OXFORD,CT 06478 PHONE:(203)262-9245 FAX-(203)262-9243 EVALUATION REPORT Pollyglass USA,Inc. Evaluatidn Report P12060.02.09-1117 FL5259-R22 150 Lyon Drive Fernley,NV 98408 D to 10f Issuance:02/24/2009 Revision 17:02/23/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regul tions governing the use of consttuction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code Residential Volume. The Building products described herein have been evaluated for compliance with the 2010 Florida BU,ilding Code sections noted herein. LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONIIIINUED COMPLIANCE:This Evaluation Report is valid until such time as the named produ 1(s)I changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the pr 6uchange. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Ni�mirien, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity}ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. I ADVERUSEMENT:The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. if any portion of the Evaluation Report is displayed,then it shall be JovI in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the 9seriby the manufacturer or .1 its distributors and shall be available for inspection at the job site at the request of the Built ingj Official. This Evaluation Report consists of pages I through 11. Prepared by: k' ,?z si, facsimile seat a pearingwasauftrized Thefacs p by Robert Nicrrdneril P.E.on 02/23/20Z Robert J.M.Nierninen,P.E. 1% vel Thisdoesnatse, ?s an electronically signed document Signed,seated hardtoples have been transaftled tothe Florida Registration No.59166,Florida DCA ANE1983 Product Approval Administrator and to the no med dient CERTIFICATION OF INDEPENDENCE: 'ilny company manufacturing or 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in distributing products it evaluates. -11 1 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing prods ea it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 11 1 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involvein the approval process of the product 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or ilesigh guidance unless retained specifically for that purpose. Il I TPJNITYIERD Entity Examination Reference Date ERD UST 6049) Wind Uplift P39680.03.13 03104/2013 ERD(TST 6049) Physical Properties P45370.04_13 f 04126/2013 ERD(TST 6049) Wind Uplift P1738.02.07-112 1 04/29/2013 ERD(TST 6049) Wind Uplift 11757.04.01-1-RI 04/30/2013 ERD(TST 6049) Wind Uplift P41630.08.13 0806/2013 ERD(TST 6049) Wind Uplift P11751.05.03-RI 11126/2013 ERD(TST 6049) Wind Uplift P11781.11.03-RI I 11126/2013 ERD(TST 6049) Physical Properties P45270.05.14 05112/20140910812014 ERD(TST 6049) Physical Properties 6020.07.14-1 ERD(TST 6049) Physical Properties 6020.09.14-2 09108/2014 ERD(M 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD(TST 6049) Physical Properties 6020.09.14-4 I09/08/2014 ERD(TST 6049) Physical Properties 6020-09.14-5 I 09/08/2014 ERD W 6049) Physical Properties 6020.09.14-6 09108/2014 ERD(TST 6049) Physical Properties P46S20.10.14 10/03/2014 ERD(TST 6049) Physical Properties P44360.10.14 10107/2014 ERD(TST 6049) Physical Properties P43290.10.14 10117/2014 ERD(TST 6049) Physical Properties PLYG-SC7550.14 11125/2014 [CC-ES(EVL 2396) IBC Compliance ESR-1697 l 11101/2014 Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717.08 01122/2015 Polygtass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule-Hide Cross LIg 03101/2= Polyglass USA Materials Affidavit Polystick SA Compound I i 08118/2011 UL,LLC_(QUA9625) Quality Control Service Confirmation,R14571,2QA Exp.08/08/2015 U1,LLC_(CLUA9625) Quality Control Service Confirmation,MTS,PLUS i Exp.07/0112017 4. PRODUCT DEsatiprnom 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced,SBS modified bitumen base sheet. 4,1.2 Elastobase P is a polyester-reinforced,SBS modified bitumen base sheet. 4.2 Seff-AdherunL7 Undleillaynnents: 4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,,glass s fiber reinforced,surfaced with polyolefinic film surface;meets ASTM D1970 and TAS 103. 4.2.2 Polystick NITS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly-film surface;meets TAS 103. CCZ!3 WEImembrane;7gli, _fibeF_Ke��6@Lc� Polystick-IR:,X�Fi§—zf'Wdmitial-602m!l"thiek-robi5e—etie-d-;59-p —S. aggregate surface;meets ASTM D1970. embrae,glass fiber reinforced,with a 4.2.4 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, polyester fabric surface;meets ASTM D1970 and TAS 103. II 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane,Blas -fiber/polyester reinforced, with a granular surface;meets ASTM D1970 and TAS 103. �I 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing memb ne with a 190 g/m2 polyester fabric surface;meets ASTM D1970 and TAS 103. 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP: Sheet (FR) are polyester reinforced,APP modified bitumen cap sheets;meet ASTM D6222. il cap 4.2.8 Polystick Dual Pro'" is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970. 4.2.9 Polystick Tile Prom is a nominal 611-mil thick dual-layer rubberized asphalt water�prciofing membrane, fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103. 4.3 Mechanically Fastened and/or Bonded Uncleflayments: 4.3.1 Elastoflex SIS G and Elastoflex S6 G FR are polyester reinforced,SBS modified bitumen cap sheets;meet ASTM D6164. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced,APP modified bitumen cap sheets+eelt ASTM D6222. Exterior Research and Design,LLC Evaluation Report P12060.02.094U7 C-fffl--ofAutharhation 09503 FL5259-R22 Revision l7:02/23/2025 Page 3 of 11 ERD N [J INITY. 5. Limiwiow 5.1 This is a building code evaluation. Neither TrinitV ERD nor Robert Nieminen, P.E.are, in any way, the Designer of 11 Record for any project on which this Evaluation Report or previous versions thereof, is%was used for permitting or design guidance unless retained specifically for that purpose. II i 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire ratings of this product. 1 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the roduct is specifically referenced within FBC approval documents. If not listed,a request may be made to the AH!fora 3proval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are as follows: �TABLEI-ROGFCOVEROkOM Underlayment AsphaltShin.gles Nall-On Tile Foam-On Tile Metal Wood Shakes& slate Shinstes Elasiobase Yes Yes No Yes Yes Yes Efastobase P Yes Yes No Yes yes Yes Polystick MTs Yes Yes No Yes I Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick iR-xe Yes No No No 4 Yes yes PoWckTU P See&S.1 Yes Yes Yes No yes Yes Polystick Tu Plus Yes Yes Yes Yes i Yes Yes See 5.5.1 Polystick TU Max No Yes See Yes yes No No 5.5.1 PoWck Dual Pro yes Yes No Yes yes Yes Polystick Tile Pro yes Yes See YeSs Yes Yes Yes -1U Elastoflex S6 6 Yes Yes Yes See Sal No Yes Yes Elastoflex S6 6 FR Yes Yes No No Yes Yes PolVflex G Yes Yes Yes No i Yes Yes See 5.5-1 Polyflex G FR Yes Yes No No Yes Yes Yes PoWex SAP or SAP FR Yes Yes No Yes Yes See 5.5.1 Mule-Hide SA-APIP rapSheet or SA- Yes Yes No Yes Yes Se APP Cap Sheet(FR) Yes See 5.5.1 5.5.1 "Foam-On rile"is limited to use of the following Approved the adhesives unless tensile fidhesion J long term aging data from an accredited testing laboratory is provided. I ✓ 3M"°2-Component Roof Tile Adhesive AH-160{formerly Polyfmin PolyPro AH160)- PaIystick TU P,Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex,SA Cap FR,Mul Hide SA APP Cap Sheet or Mule-Hide SA-APP Cap Sheet(FR)or Tile Pro. ✓ 3MI Foam Roof-rile Adhesive RTA-1: Polystick TU P,Polystick TU Plus,Polystick U Max,Elastoflex S6 G,Polyflex G,Polyflex SAP,Polyflex SA Cap FR,Mule-Hide SA-APP Cap Sheet or Mule-Hide SA-APP&p Sheet(FR)orTifle Pro ✓ Dow TifeBond: Polystick TU P,Polystick TU Plus,Polyflex SAP or Tile Pro 1 ✓ Convenience Products'Touch In Seal StonnBond RoofTileAdhesive: Polystick TU P luJPolyst1ckTUMax Exterior Research and Design,LLC Evaluation Report P12060.02-094U7 Certykate ofAuthorizodon 09503 fJ FL5259-R22 Revision 17.02/23/2015 Page 4 of 11 INITYIERD U Max-,i i�_1-440 i XaJCap Sheet or SA2, APP Cap Sheet(FIR),Dual Pro or Tile Pro:! 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 un'derlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 For non-tile applications: 6.4.2.1 All self-adhering materials,with the exception of Polystick TU Plus,Polyflex SAP or SAP FIR and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR)should be back-nailed in selvage edge seam in ac and I e with Potyglass/Mule-Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type Virith'a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of 12"o.c. Polystiii TU Plus should be back-nailed using the above noted fasteners and spacing,in area marked"nail area,area para claval"on the face of membrane. The head lap membrane is to cover the area being back-nailed 6.4.2.2 All seat-lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro,align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). rq" A� 5, View of Ovelap Seam of Dual Pro a I d Tit I e Pro 6.4.2.3 All over-fabric and over-granule end-laps shall have a 6-inch wide, uniform layer oPolyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement Polyglass yglass PG500 MB Flashing Cement,Polystick TU Plus-rite Underlayment Flashing Cement,Mule-Hide 241 Pre 11 iuml Modified Flashing Cement, Mule-Hide 251 Premium Wet/Dry Electrometric Flashing Cement, or Mule-Hide 121 Mod Bit Flashing Adhesive Trowel Grade mastic,applied in between the application of the lap. 6.4.2.4 Polystick TU Plus,Dual Pro and Tile Pro may not be used in any exposed application such crickets,exposed valleys, or exposed roof to wall details 6.4.2.5 Repair of Polystick membranes is to be accomplished by applying Polyglass Polypluill 55 1 Premium Modified Flashing Cement,Polyglass;Polyplus 50 Premium MB Flashing Cement,Polyglass PGSOO MB FlIshing Cement,Polystick TU Plus Tile Underlayment Flashing Cement, Mule-Hide 241 Premium Modified Flashing Cement, Mule-Hide 251 Premium Wet/Dry Elastomenc Flashing Cement,or Mule-Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of repair,followed by a minimum 6 x 6 inch patch of the Polystick material o like',kind,set and hand rolled in place over the repair area. Patch laps,if needed,shall be installed in a water shedding manner. 11 i 6.4.2.6 All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a 11I i minimum of 40-lb weighted-roller or,on steep slopes,use of a stiff broom with approximately 4bs of load applied ! I for the field membrane. Hand rollers are acceptable for rolling of patches,laps(mi 1.28.lb roller or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 For tile applications(not allowed for Polystick IR Xe): 6.4.3.1 Reference is made to Section 6.4.2 herein in conjunction with FRSA/TRI 0732)0//S i 5 ILtallation manual, Fourth I Edition,Table 2 herein and Section 55.4 herein,using the instructions noted above a a guideline. 6.4.3.2 For nail-on tile systems over Polystick MTS,battens are required for loading/staging of the tile. 6.4.3.3 For nail-on tile systems over Polystick MTS PWS: > Battens are required for loading/stagmgof lugged the regardless of slope. > Battens are required for loading/staging of flat tile at slopes in excess of 5:12. it Exterior Research and Design,LLQ Ev luati I on Report P12060.02.09-RI7 Ceroflo:W OfAuthoraoftian 09SO3 FL5259-R22 Revision 17-02/23/2015 Page 10 of 11 Business &- Prof'osSional�..Regulationc q AoMa Departmentof BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications I FBC Staff BCIS Site Map Links I Search Busines ) a Product Approval Professi l USER:Public User Regulation - Product Approval Menu>Product or Application Search>Application List>Application Detail FL# fL-.U674R9"" Application Type Revision Code Version 2010 Application Status Approved Comments Archived Product Manufacturerwens`Coming Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Coming PKWY Toledo,OH 43659 (419)376-8360 me[-sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Wj Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 07/17/2017 Validated By John W. Knezevich, PE 9 Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R9 COI 2014 01 COI Nieminen odf Referenced Standard and Year(of Standard) standard Year ASTM D3161,Class F 2006 ASTM D3462 2007 ASTM D7158,Class H 2007 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/28/2014 Date Validated 03/05/2014 Date Pending FBC Approval 03/05/2014 Date Approved 04/18/2014 Summary of Products FL* Model,Number or Name Description 1067 1 wens;C9ming Asphalt.Roofin � `� g 34`tab,4-tab,5atal,lariainated',_stacter Ipi&ddge Shingles �,Fingles and`Staiters Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R9 II 2014 03 FINAL OC Asphalt Approved for use outside HVHZ:Yes Shingles FL10674-R9.pddf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE-59166 Design Pressure:N/A Created by Independent Third Party: Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R9 AE 2014 03 FINAL OC Asphalt Shingles FL10674-119.0f Created by Independent Third Party: Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please dick here. Product Approval Accepts: MM99M securitv.NiL•nuC5 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization#9503 TRINITY I ERD 353 CHRISTIANOXFORD,, UNIT #13 CT 6478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-R4 One Owens Corning Parkway FL10674-R9 Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 4: 03/04/2014 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: The facsimile seal appearing was authorized :.� ;;_` a;spF=;'�•z. by Robert Nieminen,P.E.on 03/04/2014 This does not serve as an electronically signed +;�d'S•:T':�$�:�• document. Signed,sealed hardcopies have been Robert7.M. Nieminen, P.E. t �'��O\a�-%;r•.. t2nsmittedtotheProductApprovalAdminishatorand Florida Registration No. 59166,Florida DG4 ANE1983 i�""��°�""� to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. QC1 TRINiTY l ER® ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161,Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire® are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire'"' are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition° Duration°, Duration° Premium Cool, TruDefinition° Duration® Designer Color Collection, TruDefinition® Oakridge°, Oakridge® and WeatherGuard° HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire® Hip &Ridge Shingles, High Ridge, Hip &Ridge with Sealant, WeatherGuard® HP Hip & Ridge Shingles, Pro Edge Hip & Ridge Shingles and DuraRidgeT" Hip 8& Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4:03/04/2014 Page 2 of 7 CFTRINITYiERD 5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vint = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ .WeatherGuardO HP shingles require minimum six (6) nails per shingle. ➢ DevonshireTm shingles require minimum six (6) nails per shingle. ➢ Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-119 Revision 4:03/04/2014 Page 3 of 7 ( 0 � TRINITY I'ER® f 6.2.5 Minimum Nailing - Classic@ &Supreme: Normal Mansard or Area.pars Normal Mansard or Area para Wind Areas High Wind desvanas y Wind Areas High Wind desvant3s y Area para vientos normeles Areas vientos fnertes Area para vientos normales Areas vientos fuartes �"tr (A) �` ��" z• IB rz' 1. 1" (A) �. `�. 2- E21 . {BI 2. 1. �z t tz i S Exposure 56/S'Exposure Exposicidn- Expasici¢n 6.2.6 Minimum Nailing - Berkshire@: Sealant strip. Sealant strip Win de settador la Ura de sdkdor �� �l —► • 1--�-0 164---------►• 04---- )w 8 Yz" 9:Yt 9 IT 8 Yf 8 lip a Yf 8 Yr r r r- .fi. Asphalt'roof n9 cemeni Cerimnio de techo de astafto 6.2.7 Minimum Nailing - DevonshireTM': Nails r r a• a r r r e r �.. u. ias s Nails Ten 1"Spots of Asphalt Roof Cement 6.2.8 Minimum Nailing - Duration@, Tru Definition® Duration, Duration@ Premium Cool & TruDefinition® Duration® Designer Color Collection: 4 Nal Nttem 6 Nail kbrsardand StupreSloFlrr° pp� Esquema de,4 ffito bilin.Sudavos Pattern artaandtrd d eu2 ou<. Esquema — c fl a ope dm das SureJOaipbstening area width de Sdavos, agmasNpdaseeea d Area de damsSuieNail� •: a • 2aasueMa rbperla . xyerfa�lraab. 1• SwNaO 1� ara areasN n _ 12' 12' _ Amada t' \1 lr;�oy sur F�a&' 12' ` ^-17' 59s"Exposure Nass 615"'6cposure Ph 01g.do exposidda clavus Vhpulg.deexpasrclda 5Y;Exposure Nails STFxpo=m 6%putg.deexposfWrr davos .5%pulg.deexMsiddm Exterior Research and Design,LLC. Evacuation Report 037940.02.12-1114 Certificate of Authorization#9503 FL10674-R9 Revision 4:03/04/2014 Page 4 of 7 • 1�4� 1�R11\IIIY J ER® 6.2.9 Minimum Nailing -TruDefinition°Oakridge@, Oakridge@: 4 Nall Pattem 6 Nail Pattem Esquema con 4 davas Esquema con 6 clavas 1. 1. r r it F ir 55/8"ExposureNags 5 518"Exposure Nags Exposkidn de 66/8pa1g. Claws Exposiabn de 55/Bpu(g. 5 W Expcsum Clavus 5 518"Exposure Erpos1d6nds66/5ping Exposiddnde6618p g. 6.2.10 Minimum Nailing -WeatherGuard@ HP: f� Side Vbw 2. 611i1rb 'Sam' •{':;:"► •�;:•:: Clw�an f�ifw ti flprJir 6.3 Hip &Ridge Shingles: 6.3.1 Installation of Berkshire® Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4:03/04/2014 Page 5 of 7 QOTRINITYIERD 6.3.3 Minimum Nailing — Berkshire@ Hip &Ridge and High Ridge: Fig.1 4 Fig.2 �— Pnarairing�nd Direction A TopView $I11eVieal Nags A Hans Nails 4 1' Top Laninatal 2" 1 A 1 i 4' Piece 4 I I I I I j j I A 1 I I I P 1 I i I ml osure � i V' 1 1 I 1 I 6.3.4 Minimum Nailing — Hip &Ridge with Sealant: em Fig.2 -HighWitd Fastening Fattem KNOW— rim°Shingle- nd D.iscard-12; rb*Sealant Strip �2,,. ' Fastening; 55/$" 5"Fxposure distance � I -I P+= 12 6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge: Fig.A 4 q Fig,C Hip&Ridge.Shingle Fastening Prevatling Wind Top View �—Dlreelbn p A Halls 4 4 A i i 172119 Nails Y 7' 2" 1 I T 1' Exposure 61 Exposure Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4:03/04/2014 Page 6 of 7 TRINITY�ER® 6.3.6 Minimum Nailing - ProEdge Hip &Ridge Shingles: Prevailing Standard Wind Direction Sealant stri Fastening p Pattern W EVosure • 12' 1 Sealant Fasten 71j,' 7 Il? ILL 6"Exposure Cover Exposed � 1 Fasteners with Roof Cement 6.3.7 Minimum Nailing — DuraRidge'TM Hip &Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. �-BYang Wind N-don Top View irottion domimnta CUM= VW en DiraoddndaN&ntopradornimnta II" Viistasuperior 1'I I Q � 21e :�"., ..,Orrem ConingSuteNaH• 6'•avo- 61a°sm\ _iI I i I �j � I I � I � i �1 � 8- -C I€« I . �ti 1(b• u l� n I IT I 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/ R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R4 Certificate of Authorization#9503 FL10674-R9 Revision 4:03/04/2014 Page 7 of 7