Loading...
HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization#9503 TRINITY I 353 Christian Street QOERD Oxford, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT CertainTeed Corporation Evaluation Report C33260.06.10-111 1400 Union Meeting Road FL477-R5 Blue Bell, PA 19422 Date of Issuance: 06/29/2010 Revision 1: 12/05/2011 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been designed to comply with the 2010 Florida Building Code. DESCRIPTION: Flintglas® Built-Up Roof Systems LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 25-page Appendix. Prepared by: C= The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 12/05/2011 This does not serve as an electronically signed Robert].M. Nieminen, P.E. .�` C�� L{ . document. Signed,sealed hardcoples have been Florida Registration No. 59166, Florida DCA ANE1983 i'; �������la� r� transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. QOTRINI-ryIERD 8. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover or re-roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52,ANSI/SPRI IA-1 or TAS 124. 12. For Recover Applications using System Type D,the insulation is optional; however,the existing roof system shall be suitable for a recover application. 13. Unless otherwise noted, a Flintglas@ Built-Up Roof Cover consists of one of the following. Systems shall be surfaced in accordance with CertainTeed requirements to meet the fire resistance requirements of FBC 1505.1. ystem Tyae Description Three or four plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI applied in hot asphalt at 25 Ib/square with.flood coat&gravel or approved roof coating. 2 One ply Glasbase, All Weather/Empire Base, Flexiglas Base or Flintlastic Base 20 followed by two or three plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI applied in hot asphalt at 25 Ib/square with flood coat&gravel or approved roof coating. Two or three plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply,Sheet Type VI, followed by Flintglas Mineral Surface Cap or .. Flintlgas Mineral Surface Cap CoolStar applied in hot asphalt at 25 Ib/square. 4 / (.One ly-GlasSase; All Weather/Empire Base, Flexiglas Base or Flintlastic Base 20 followed by two or three plies Flintglas Ply Sheet Type JV or Flintglas premium Ply Sheet Type VI,followed by Flintglas Mineral Surface Cap or Flintlgas Mineral Surface Cap CoolStar applied in hot asphalt at 25 lb/square. 5 Yosemite Venting Base applied in hot asphalt in 24-inch diameter spots in grid with spots spaced 30-inch o.c. followed by two or three plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI applied in hot asphalt at 25 Ib/square with flood coat&gravel or approved roof coating. 6 Yosemite Venting Base applied in hot asphalt in 24-inch diameter spots in grid with spots spaced 30-inch o.c. followed by one or two plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI, followed by Flintglas Mineral Surface Cap or Flintlgas Mineral Surface Cap CoolStar applied in hot asphalt at 25 Ib/square. 7 Black Diamond Base Sheet or Flintlastic UltraGlass SA self-adhered, followed by two or three plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI applied in hot asphalt at 25 Ib/square with flood coat&gravel or approved roof coating. 8 Black Diamond Base Sheet or Flintlastic UltraGlass SA self-adhered, followed by one or two plies Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI, followed by Flintglas Mineral Surface Cap or Flintlgas Mineral Surface Cap CoolStar applied in hot asphalt at 25 Ib/square. 14. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. Exterior Research and Design,LLC.d/b/a TrinitylERD Evaluation Report C33260.06.10-R1 for FL477-115 Certificate of Authorization#9503 Revision 1: 12/05/2011 Appendix 1,Page 3 of 25 Prepared by: Robert Nieminen,PE-59166 �TRINIWIERD 5.8 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.9 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.10 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.11 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. 5.12 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 9N-3. 6. INSTALLATION: 6.1 Flintglas@ Built-Up Roof Systems shall be installed in accordance with CertainTeed Corporation published installation instructions, subject to the Limitations/ Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. S. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 9N-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: Underwriters Laboratories - QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com - THE 25-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior Research and Design, LLC. Evaluation Report C33260.06.10-111 Certificate of Authorization#9503 FL477-R5 Revision 1: 12/05/2011 Page 4 of 4 TRINITY JERD TABLE IE-1: WOOD DECKS—NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet No. (See Note 1) Base Fasteners Attach Roof Cover MOP(Psf) CONVENTIONAL SYSTEMS. Min.19/32-inch thick exterior Glasbase; Flexiglas;Flintlastic 32 ga.,1-5/8-inch dia.tin caps W-18 grade plywood attached per Base 20;All Weather/Empire with 11 ga.annular ring shank 9-Inch o.c.at 4-Inch lap and 12-Inch o.c.In System 1,2,3 Code. Base or Poly SMS Base nails two,equally spaced,staggered center rows or 4 -45,0* Min.15/32-inch plywood at max Glasbase;Flexiglas;Flintlastic W-19 24-Inch spans attach 6-Inch o.c. Base 20;All Weather/Empire Min.1-inch long,12 ga.Simplex 6-inch o.c.at 3-inch lap and 6-inch o.c.in System 1,2,3 -52.5 using 8d ring shank nails Base or Poly SMS Base Metal Cap Nails four,equally spaced,staggered center rows or4 Min.19/32-Inch plywood at max 32 ga.,1-5/8-inch dia.tin caps W-20 24-Inch spans attach 6-inch o.c. Glasbase;Flexiglas;Flintlastic with 11 ga.annular ring shank 8-inch o.c.at 4-Inch lap and 8-inch o.c.in Sstem 3 or 40 -52.5 using 8d common nails Base 20 or Poly SMS Base nails three,equally spaced,staggered center rows y Min.19/32-Inch plywood at max 32 ga.,1-5/8-inch dia.tin caps W-21 Glasbase; Flexiglas;Flintlastic 8-inch o.c.at 4-Inch lap and 8-inch in 24-Inch spans attach 6-inch o.c. o.c.Base 20;Poly SMS Base with 11 ga.annular ring shank System 3 or 4 -60.0 using Sd ring shank nails nails three,equally spaced,staggered center rows Min.19/32-Inch plywood at max 32 ga 1-5/8-inch dia.tin caps W-22 24-Inch spans attach 6-inch o.c Glasbase;Flexiglas; Flintlastic it ga.annular ring shank 6-Inch o.c.at 4-Inch lap and 6-Inch o.c.in System 3 or 4 -82.5 using#8 wood screws Base 20;Poly SMS Base with four,equally spaced,staggered center rows nails Min.19/32-Inch plywood at max 32 ga.,1-5/8-inch dia.tin caps W-23 Glasbase; Flexiglas;Flintlastic 4-Inch o.c.at 3-Inch lap and 4-Inch o.c.In 24-inch spans attach 6-inch o,c. i Base 20;Poly SMS Base with 11 ga.annular ring shank four,equally spaced,staggered center rows System 3 or 4 -105.0 using#8 wood screws nails HysRio SYSTEMS, Min.19/32-inch thick exterior Glasbase;Flexiglas;Flintlastic 32 ga.,1-5/8-inch dia.tin caps W-24 grade plywood attached per Base 20;All Weather/Empire with 11 ga.annular ring shank 9-Inch o.c.at 4-Inch lap and 12-inch o.c.in Code. Base;Poly SMS Base nails two,equally spaced,staggered center rows System 8 -45.0* Min.15/32-Inch plywood at max Glasbase;Flexiglas;Flintlastic W-25 24-inch spans attach 6-inch o.c. Base 20;All Weather/Empire Min,1-Inch long,12 ga.Simplex 6-inch o.c.at 3-Inch lap and 6-inch o.c.in System 7 or 8 -52.5 using 8d ring shank nails Base;Poly SMS Base Metal Cap Nails four,equally spaced,staggered center rows Min.19/32-inch plywood at max 32 ga I-5/8-inch dia.tin caps Glasbase;Flexiglas;Flintlastic 8-inch o.c.at 4-Inch lap and 8-Inch o.c.In W-26 24-Inch spans attach 6-inch o.c. with 11 ga.annular ring shank Sstem 8 -52.5 using 8d common nails Base 20;Poly SMS Base nails three,equally spaced,staggered center rows y Min.19/32-inch plywood at max 32 ga 1-518-inch dia.tin caps Glasbase;Flexiglas;Flintlastic 8-Inch o. .at 4-inch lap and 8-inch o.c.in W-27 24-inch spans attach 6-inch o.c. with 11 ga.annular ring shank cI System 8 -60.0 Base 2 using 8d ring shank nails 0; Poly SMS Base nails three,equally spaced,staggered center rows Min,19/32-inch plywood at max 32 ga.,1-5/8-inch dia.tin caps W-28 24-Inch spans attach 6-Inch o,c. Glasbase;Flexiglas;Flintlastic 6-Inch o.c.at 4-Inch lap and 6-Inch o.c.In Base 20; Poly SMS Base with 11 ga.annular ring four, System 8 -82.5 using#8 wood screws nails our,equally spaced,staggered center rows In and 4-Inch o at 3-Inch lap p .c. Min,19/32-Inch plywood at max Glasbase;Flexiglas;Flintlastic 32 ga.,1-5/8-inch dia.tin caps W-29 24-Inch spans attach 6-Inch o.c. with 11 ga.annular ring shank 4-Inch o. S using#8 wood screws I Base 20;Poly SMS Base nails four,equally spaced,staggered center rows ystem 8 -105.0 Exterior Research and Design,I-I-C.d/b/a Trinity[ERD Evaluation Report C33260.06.10-RI for FL477-R5 Certificate of Authorization#9503 Revision 1: 12/05/2011 Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 8 of 25 rioriaa tjuuamg Loae ymme rage i or Hol(�d2(J arnefltc! SCIS Home 1 log In j User Registration Hot Topics i Submit Surcharge Stats&Fads Publications FBC Staff SCIS Site Map ' Links Search Busines.3'r1 - ProfessibhraI E ►USeedPubtApproval Regulation Product Approval Menu>Product or Application Search>Aoolication List>Application Detail FL# FL477-RS Application Type Revision Code Version 2010 Application Status Approved Comments Archlved Product Manufacturer CertainTeed Corporation-Roofing Address/Phone/Email PO Box 1100 1400 Union Meeting Rd Blue Bell,PA 19422 (215)274-2350 Steven.T.Lawrey@saint-gobain.com Authorized Signature Steven Lawrey Steven.T.Lawrey@saint-gobain.com Technical Representative Barb McDonough Address/Phone/Email 750 E.Swedesford Road Valley Forge,PA 19482 (610)341-6721 Barbara.A.McDonough@saint-gobain.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Built up Roofing t Compliance Method Evaluation Report from a Florida Registered Architect or a Lici!sed Florida Professional Engineer Evaluation Report-Hardcopy Received -` Y•_ _ Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report - - _ v ;��:�A Florida License PE-59166 Quality Assurance Entity Underwriters Laboratories Inc. Quality Assurance Contract Expiration Date 12/15/2014 "•- ylT Validated By John W.Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL477 R5 CO1 Trinity ERD Cl-Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D2178 2004 ASTM D3909 1997 ASTM D4601 2004 ASTM D4897 2001 FM 4470 1992 FM 4474 2004 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvij WrK4oKmN... 6/17/2013 .rlonaa nuuamg Loae unime rage L or Product Approval Method Method 1 Option D Date Submitted 12/15/2011 Date Validated 12/16/2011 Date Pending FBC Approval 12/21/2011 Date Approved 01/31/2012 ;Summary of Products FL# 114odel,Number or Name Description 477.1 Flintglas Built-Up Roof Systems Built Up roof Systems Limits of Use Installation Instructions Approved for use in HVHZ:No FL477 RS II Al er120511FiNAL CERTAINTEED BUR FL477-R5.odf i j Approved for use outside HVHZ:Yes Verified By:Robert Nieminen PE-59166 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:+N/A/-430 Evaluation Reports j Other:1.)The DP listed in this application relates to one specific FL477 R5 AE er120511FINAL CERTAINTEED BUR FL477-R5.odf I assembly.Refer to the ER Appendix for all assemblies and max design Created by Independent Third Party:Yes pressures.2.)Refer to ER Section 5 for limits of Use. Contact Us::1940 North Monme Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2010 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: IMM Wel zL_,i M securitvmm iucs http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvijwrK4oKniN... 6/17/2013 TRiNITY!ERD i APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4 18 Wood New, Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation, Bonded Roof Cover 5 iC Wood New, Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 5 1D Wood New, Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6-7 SE-1 Wood New, Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover B 1E-2 -Wood New, Reroof(Tear-Off).or Recover E Non-Insulated, Mech.Attached Base Sheet, Bonded Roof Cover 9 2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation, Bonded Roof Cover 10 2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation, Bonded Roof Cover 11-12 2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13 3A Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 14-15 3B Concrete New or Reroof(Tear-Off) F Non-Insulated, Bonded Roof Cover 15 4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 16 4B LWIC New, Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 17-18 SA CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 19 5B CWF New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet;Bonded Insulation,Bonded Roof Cover 20 5C CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 21 5D CWF New,Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 21 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22 6B Gypsum Reroof(Tear-Off) A-2 Mech,Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 23 v 6C Gypsum Reroof(Tear-Off) C Mech.Attached Insulation,Bonded Roof Cover 24 6D Gypsum Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25 The following notes apply to the systems outlined herein: 1. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AH]. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows.i Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMGI3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round Insulation Plate,Tru-Fast HD with MP-3 Plates or FlintFast #14 Fastener with FlintFast 3"Insulation Plates. Minimum 3/4-Inch plywood penetration or minimum 1-inch wood plank embedment. Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast#12 or#14 with Hex Plate or 3"Round Insulation Plate,Tru-Fast DP or HD with MP-3 or FlintFast#12 or#14 Fastener with FlintFast 3"Insulation Plates. Minimum 3/4-inch steel penetration and engage the top flute of the steel deck. Concrete Deck: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast#14 or DekSpike with Hex Plate or 3" Round Insulation Plate,Tru-Fast HD or CF with MP-3 or FlintFast#14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-Inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation Instructions. • Exterior Research and Design,LLC.d/b/a TrinitylERD Evaluation Report C33260.06.10-111 for FL477-RS Certificate of Authorization#9503 Revision 1: 12/05/2011 Prepared by: Robert Nleminen,PE-59166 Appendix 1,Page 1 of 25 l-RfN1 'Y i ERD i TABLE IE-1: WOOD DECKS-NEW CONSTRUCTION or REROOF(Tear-Off) SYSTEM TYPE E: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover MDP(psf) No. (See Note 1) Base Fasteners Attach CONVENTIONAL SYSTEMS: Mln,19/32-Inch thick exterior Glasbase;Flexiglas; Filntlastic 32 ga.,1-5/8-Inch dia.tin caps 9-Inc o.c.at 4-Inch lap and 12-Inch o.c.In System 1,2,3 W-18 grade plywood attached per Base 20;All Weather/Empire with 11 ga.annular ring shank -45.0" Code. Base or Poly SMS Baser�t nallss / two,equally spaced,staggered centteer rrogwwss or 4 j M� � n aE Ieh'o§§J. � shzs I atj�er'/EI �NflnWil- n nd'g/12 a' plhx IIa�aFc�lTp a Br cefiterTws/ d cf8 fjng.gh ny,rfal s� Ba or d�SMS Base �/ Lr Min.19/32-Inch plywood at max Glasbase;Flexiglas;Flintlastic r 32 ga.,1-5/8-Inch dia:tin caps 8-Inch o.cl,at 4-Inch lap and 8-Inch o.c.In using Bd common nailsis nails W-20 24-Inch spans attach Inch o.c. Base 20 or Poly SMS Base with 11 ga,annular ring shank three,equally spaced,staggered center rows System 3 or 4 -52.5 Mln.19/32-Inch plywood at max 32 ga.,1-5/8-Inch dia.tin caps W-21 24-Inch spans attach 6-Inch o.c. Glasbase;Flexiglas;Flintlastic with 11 ga.annular ring shank 8-Inch o.c.at 4-Inch lap and B-Inch o.c.In System 3 or 4 60.0 using 8d ring shank nails Base 20;Poly SMS Base nalls three,equally spaced,staggered center rows Min,19/32-Inch plywood at max Glasbase;Flexlglas; Flintlastic 32 ga.,1-5/8-Inch dia,tin caps 6-Inch o.c.at 4-Inch lap and 6-Inch o.c.In W-22 24-Inch spans attach 6-Inch o.c. Base 20• Poly SMS Base with 11 ga.annular ring shank four,equally spaced,staggered center rows System 3 or 4 62.5 using#8 wood screws nails Min.19/32-Inch plywood at max Glasbase;Flexlglas;Flintlastic 32 ga.,1-5/8-Inch dia,tin caps 4-Inch o.c,at 3-Inch lap and 4-Inch o.c.In W-23 24-Inch spans attach 6-Inch o.c. Base 20; Poly SMS Base with 11 ga.annular ring shank Four,equally spaced,staggered center rows System 3 or 4 105.0 using#8 wood screws nails HYBRID SYSTEMS: Min.19/32-Inch thick exterior Glasbase;Flexiglas; Flintlastic 32 ga.,1-5/8-Inch dia.tin caps g inch o.c.at 4-Inch lap and 12-Inch o.c.In « W-24 grade plywood attached per Base 20;All Weather/Empire with 11 ga,annular ring shank System 8 -45.0 Code. Base; Poly SMS Base nails two,equally spaced,staggered center rows Mln.15/32-Inch plywood at max Glasbase;Flexiglas; Flintlastic Mln. 1-Inch long,12 ga,Simplex 6-Inch o.c,at 3-Inch lap and 6-Inch o.c.In using ed ring shank polis Base;Poo ly SMS Base W-25 24-Inch spans attach 6-Inch a.c. Base 2 All Weather/Empire Metal Cap Nails four,equally spaced,staggered center rows System 7 or 8 -52.5 Min.19/32-Inch plywood at max Glasbase;Flexlglas; Flintlastic 32 ga.,1-5/8-Inch dia.tin caps 8-Inch o.c:at 4-Inch lap and 6-Inch o.c.In using ed common nailsis palls W-26 24-Inch spans attach Inch o.c. Base 20; Poly SMS Base with 11 ga.annular ring shank three,equally spaced,staggered center rows System 8 -52.5 Min.19/32-Inch plywood at max Glasbase;Flexiglas;Flintlastic 32 ga.,1-5/8-Inch dia,tin caps B-Inch o.c;at 4-Inch lap and 8-Inch o.c.In W-27 24-Inch spans attach 6-Inch o.c. Base 20; Poly SMS Base with 11 ga.annular ring shank three,equally spaced,staggered center rows System 8 -60.0 using 8d ring shank nails nails Min.19/32-Inch plywood at max 32 ga.,1-5/8-Inch dia,tin caps W-28 24-Inch spans attach 6-Inch o.c. Glasbase;Flexiglas; Filntlastic with 11 a.annular rip shank 6-Inch o.c:at 4-Inch lap and 6-Inch o.c.In p Base-20;Poly SMS Base 9 9 four,equally spaced,staggered center rows System 8 -82.5 using#8 wood screws palls Min.19/32-Inch plywood at max 32 ga.,1-5/8-Inch dia.tin caps W-29 24-Inch s ons attach 6-Inch o,c. Glasbase;Flexiglas; Flintlastic with 11 a,annular rin shank 4-Inch D.C.:at 3-Inch lap and 4-Inch o.c.in P Base 20;Poly SMS Base 9 g four,equally spaced,staggered System 8 105.0 using#8 wood screws palls q Y P , ggered center rows y s Exterior Research and Design,LLC.d/b/a TrinitylERD Evaluation Report C33260.06.10-R1 for FL477-R5 Certificate of Authorization#9503 Revision 1: 12/05/2011 Prepared by: Robert Nleminen,PE-59166 Appendix 1,Page 8 of 25