HomeMy WebLinkAboutEngineering Asmussen Engineering LLC.
Engineering&Environmental Services
44�s P.O.Box 1998,Okeechobee,FL.34973-1998 Office:(863)763-8546 Fax:(863)467-8560
Memorandum
Date:-. May 18, 2015
To: St. Lucie County Building Department C rw T
Joe Cicio—Building Official c'mILE 0"v
2300 Virginia Avenue
Ft. Pierce, FL. 34982-5652
From: Loris C. Asmussen, P.E. ` D
Subject: Jim Gillespie
1 San Felipe
Fort Pierce, FL 34951
1985 TWIN OFFSET (24' x 52' - 24' x 63') Vehicle ID— T249P19523 A/B
This memorandum is provided to address re-roofing of a 1985 mobile home. Proposed is Gulf Rib
Roof Paneling(26 GA metal—FL 11651.22R1) as a replacement for the originally manufactured
roof. Tamko Underlayment(30#ASTM D 226)will be used. Attached are product approvals for
the paneling(#I 1651.22R1) and underlayment(FL12328-R2),which includes attachment
methodology for the rib panels and underlayment. The panels are manufactured by Gulf Coast
Supply&Manufacturing,Inc. The Engineer Evaluator of the paneling is Terrence E. Wolfe(FL.
P.E.No. 44923) and the Validator is Locke Bowden(FL P.E.No. 49704).
Based on my review of this proposed project,including product approvals and loads for which the
above-referenced structure will be exposed to at this location in St. Lucie County(160 mph 3-
second gust and exposure"C"),the project is found to be in substantial compliance with the 2010
Florida Building Code.
Any plywood, found to be damaged or in disrepair,will be replaced and fastened in a manner
similar or equivalent to that employed during manufacture of the original structure.
Sincerely,
Loris C. Asmussen, P.E.
Principle
C: Gillespie File(Fort Pierce)