Loading...
HomeMy WebLinkAboutRevisions OFFICE USE ONLY: DATE FILED: PERMIT# REVISION FEE: RECEIPT# 3A PLANNING &DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772).462-1553 FAX(772)462-1578 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE0 / ADDRESS: C{ W\YAwo. 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: G � wiovcv5 ol"- oars -ood - I . 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: ST.L CIE COUNTY CERT.#: BUSINESS NAME: �FrrGQ� QUALIFIERS NAME: ADDRESS: CITY: STATE: ST WME COUNT$: PHONE(]DAYTIME): F BUILDING DIVISION 4. OWNER/BUILDER INFORMATION: F'0`9 Oc3 m n 'p z AEVIE'N.ED BY DATE NAME: ADDRESS: r,4wFT- _ CITY: STATE: * WILL a MD E PHONE: 5. ARCHITECT/ENGINEER INFORMATION: NAME: /P.% , ADDRESS: CITY: STATE: PHONE(DAYTIME): FAX: Revised 07/22/2014 } } s w� Florida Building Code Online Page 1 of 3 n. N x5aw 1 ; s _ f I')c03itTni71lf1 BCIS Home" Log,In 1 User Registration Hot Topics i Submit Surcharge ' Stats&Facts Publications , -FBC'Staff i BCIS Ste Map•(" Links i Search Py 7[' y'',� <+ ProductApproval t�Ie��� I-1 � '3` .USER:Public - t kgulation i 'Product Approval Menu>Product orApolication:Search>•Aoolication List 5 Application Detail. I r • i fi a FC# FL228-R13' Application Type Revision Code'Verslon 2010. • Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. • I i _ E ,Comments • - - - - .r. - I ' Archived , , i Product,Mariufacturer Simonton Windows Address/Phone/,Ernall 1•"CochYane,Ave Fennsboro,WV 26415 '(800)746-6687 Ext 2329 } tiffany.davies@simonton.com -Authorized Signature. Tiffany Davies - t 1 davles@simonton.coRE 'ffany. { Techni"cal"Representative Tiffany Davies + Ad'dress/Phone/Email PO'Box 16,46 4 E '5300 Briscoe Road Parkersburg,WV 26'102 (800)542-9118 Ext 9329 i tifftiny_davies@Simonton x Quality Assura"gce;Representative• AAMA, . • :Address/Phone/Email ,1827 Walden Office Square. SuiteS50 Schaumburg,IL 60173 1 303-5664 I 'wb.b,masier@aaman..et.org i Category :'Windows - n_ Subcategory'., Fixed. ! Compliance-Method, Certification'Mark or'Listing r Certification.Agency' Arnerican'Architect6ral Manufacturers Association Ualidated:By American Architectural ManufacturersAssociation , Referenced Standard and Year,-(of Standard) Standard r ea AAMA 450 F11 f i ;; = AAMA 506 i - ,:AAMA 506 "'�E:�' AAMA/WDMA/CSA 101/I.S.2 A440 2005 ASTM"E 1886' 2005 ASTM E1996: 2009 i y ASTM E.1996 2005 , Equivalence of Product Standards Certified By Florida Ucensed'Professional Engineer or Architect FL278 R13 Equiv IN0366-RS EdLINHlenCV.N j littp8://www flondabuifding:org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqul00igpONa1,_ 5/18/2015 Florida Building Code Onlir— Page 2 of 3 Product Approval Method Method 1 Option A .Date Submitted' 10/03/2014 Date Validated 10/03/2014 Date Pending'FBC Approval Date.Approved 10/07/2014 Summary of Products FL# Model,Number or Name Description 228.1 07-09,07-0,07-20(Retrofit StormBreaker Plus.300VL;8000,Grand Estates Coastal Installation)'.' Impact Vinyl Fixed(Picture)Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL22.8 R13 C CAC 07-09 g7-20 PW Imnact 74x63 R55 Approved for use outside HVHZ:-Yes ext. df Impact Resistant:Yes FL228 R13 C CAC 07-09 PW Imnact 37x84 R50.Pdf Design Pressure:N/A FL228 R13 C CAC 07-10 and 07-20 to 07-09 Waiver of Other:37x84(+/-50 PSF),74x63(+/-55 PSF)-Missile Retest.pdf Impact Rating:.D Quality Assurance Contract Expiration Date 06/23/2016 Installation Instructions FL228 R13 II IN0366-RS pdf Verified By:American Architectural Manufacturers Association Created by Tndependent Third Party: Evaluation Reports FL22.8 R13 AE EvalRenort-IN0366-R5.pdf Created by Independent Third Party:Yes 228.2 07-20(Nailing Fin Installation) StormBreaker Plus 300VL,8000,Grand Estates Coastal Impact Vinyl Fixed(Picture)Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No 1`1_228 R13 C CAC 07-09 07-20 PW Impact 74x63 R55 Approved for use outside HVHZ:Yes ext. df ' Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+55/-55 10/01/2016 Other:74x63-Missile Impact Rating:D Installation Instructions FL228 R13 II IN0517 SP 07-20 PW 2X.odf Verified By:American Architectural Manufacturers Association Created by Independent Third Party.: Evaluation Reports Created by,Independent Third Party: 228.3 r42--19 ProFinish Brickmould 600 with SafePoint Vinyl Fixed(Picture) Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL228 R13 C CAC 42-19 PW Impact 80x48 R50.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 09/08/2016 Design Pressure:+50/-50 Installation•Instructions Other:80x48-Missile Impact Rating:C FL228 R13 II IN0551-Rl.odf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL228 R13 AE EvalReport-IN0551-R1 ndf Created by Independent Third Party:Yes 228.4 42-19 ProFinish Brickmould 6 fYwit feP nt-Vinyl F,i (P*C-W Window Twin• } Limits of Use Certification Agencyrti i e Approved for use in HVHZ:No FL228'R13 C CAC 4 19 t 7 Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date. Impact Resistant:Yes 03/06/2016 Design Pressure:+50/-50 Installation Instructions Other:73x74-Missile Impact Rating: C FL228 R13 II IN05S2 42-19 Impact PW Twin 2X.pd Verified By:American Architectural Manufacturers Association Created by Independent Third Party: https://www.floridabuilding.org/pr/pr_app_dtl.asp x?param=wGEVXQwtDqu10 igpONal... 5/1.8/2015 Florida Building Code Onlirr.- Page 1 of 1 E 1 `��`r' �`]z" '� ,r•��^'�s Iain j{k,yF,§ '' z ^ �,� .�airsaips ._ � •.L. �;�D .�� C � 0 � �ry��s9 i���� ;fy� ,A,,,y,] �� �'`" ��S ' .:.-:: _ I :} Y ��'�`�1{'�';3rw- ':i u._.:Si•;,'# -s. �'=^.a-_�..k, i :`.u,:i a 'f„!.... .'�"r. tliigle7 J:�ti(ii�ICii1a BCIS Home ' Log In User Registration Hot Topics i Submit Surcharge Stats&Facts.! Publications FBC Stalls SCIS Site Map i Links j Search ; } Byu PI��i.SJ�IJ(I�I 1 USER Pub1ct APProval Regulation g Product Approval Meru>Product or Apollcatlon Search>Application List Search Criteria Refine Search Code Version 2010 FL# 228 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance.Entity'Contract Expired ALL I Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for Use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL i Search Results-Applications Fl_# Tvae Manufacturer Validat_0 By Status FL228-R13 Revision Simonton Windows 'American Architectural Manufacturers Association Approved* ! History Category:'Windows, (214)878-1642 Subcategory:Fixed -`Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. j Contact U ::1940 North Monroe,Street Tallaha se ' 32399 Phone:850.487-1824 The State of Florida Is an AA/EEO employer.copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund:Statement Under Florida law,email addresses are public records.If you do not-want your e-mail address released In response to a'publlc-records request,do not send ' electronic mail lothisentity.Instead,contact the office by phone or by traditional mail.If you have any questions,,please contact 850.467.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective,October 1,2012,licensees'licensed under Chapter 455,F.S.must provide the'Department with an email address if they have one.The emalis provided may be used for official communication:with the licensee.However email addresses are public'iecord.If you do not wish to i supply a personal address,please provide the.Department with an email address which can be made available to the public.To determine If you are a licensee under ChapteF 455,F.S.,please clidc here.. i Product Approval Accepts: ,' WR eChc.. I xcurittivac-rl:re- ;. elt MA i i i t { 1 t i{ iq pp��1 I https://www.flotidabuilding.org/pr/pr_app_lst.aspx 5/18/20.15 Florida Building Code Onlin Rage 1 of.3 �.•�..�� ,.� c�,'�er.,.t, -x,:.v,` ;�'•�' "�,'3+ C'-�.�'v "' #..�.^�.R. $ $•3 'v`�Z .. `"•�iC}�Ss ? >� € brich D-p tmeritc; SCIS Home i Log In User Registration. ', Hot Topic Submit Surcharge Stats Ek Facts { Publications FBC staff BCIS5ite Map; Links { Search Busines Professi a1 !URPublSEEPublic i Product Anproval Menu->Product or Application Search>Application List.>Application Detail j FL.# FL5419=R1.1 Application Type Revision i Code Version 2010 Application Status Approved i `Approved by DBPR,Approvals by DBPR-shall be,reviewed and ratified by"the POC and/or;the Commission if'necessary. j Comments Archived Product ManufacturerSimonton Windows Address/Phone/Email 1 Cochrane.Ave Pennsboro,WV 26415 (800)746-6687 Ext 2329 tiffany.d6v!es@simonton.com Authorized Signature Tiffany Davies tiffany.davies@simonton.com 1 Technical Representative Tiffany Davies Address/Phone/Email PO Box 1646 5306 Briscoe Road Parkersburg;WV 26102 (800)542-9118 Ext 9329 fiffany-daviet@§imonton.com Quality Assueance.Representative AAMA Address/Phone/Email 1827 Walden Office Square E Suite 550 Schaumburg,IL 60173, (847)303-5664 i webmaster@aam6net.org f Category - Windows - 1 Subcategory -'Double'Hung i Compliance Method Certiflcation Mark.or.Listing i i Certification Agency American Architectural'Manufacturers Association Validated By American Architectural.Manufacturers Association :"-• it ��," 1 i` .���i j�J i Referenced Standard and Year(of Standard) Standard- Year AAMA 450 2010 AAMA 506 2006 AAMA 506 2008 ; i AAMA/WDMA/CSA.10.1/I.S.2/A440 2005 i AAMA/WDMA/CSA 101/I.S.2/A440. 2008, 1 ASTM E 1886 2005 ASTM E 1996 2005, ASTME 1996 2009 i Equivalence of Product Standards Certified By i https;//www.floiidabuilding:org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtHJPwMo6eH... 5/18/20:15 Florida Building Code Onlir Page.2 of 3 I k t i Product Approval Method Method 1 Option A { Date Submitted 09/12/2014 Date Validated 10/03/2014 Date Pending FBC Approval Date Approved 10/07/2014 Date Revised 03/19/2015 i Summary of Products 3 FL# Model,Number or Name Description z 5419.1 07-09/07-10/07-20(Retrofit Storm Breaker Plus 300VL,8000,Grand Estates Coastal Installation)_ Impact Vinyl':Double Hung Limits of Use Certification Agency-Certificate. Approved for use in HVHZ:No FL5419 R11 C CAC 07-09 DH ann Impact 37x76 R Approved for use outside HVHZ:Yes PG65.pdf Impact Resistant:Yes X5419 R11 C CAC 07-09 DH ann Impact 37x84 R Design Pressure:N/A PG6D,pdf Other:53 x 76(+/-55 PSF),37 x 84(+/-60 PSF),37 x 76 FL5419 R11 C CAC 07-09 DH ann Impact 53x76 R (+/-65 PSF)-Missile Impact Rating: D PL5419 R11 C CAC 07-1007-20 waiver to 07-09.ndf Quality Assurance Contract Expiration Date 04/23/2017 Installation Instructions FL5419 Ril II IN0364-R7.pdf Verified By:American'Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5419 R11 AF FvaIReno rt-IN6364-R7:pddf Created by Independent Third.Party:Yes 4 5419.2 07-20(Nailing Fin Installation) StormBreaker Plus 300VL,8000,Grand Estates-Coastal Impact Vinyl Double Hung Twin Limits of Use Certification Agency Certificate } Approved for use in HVHZ:No FI-5419 R11 C CAC 07-20 DH Impact 450 73x74 R50.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Data i Impact Resistant:Yes 03/24/2015 Design Pressure:+50/-50 Installation Instructions Other:73 x 74-Missile Impact Rating:D FL5419 R11 II IN0523 SP 07-20 DH Twin 2X.pdf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: E 5419.3 42-19 ProFinish Brickmould 600 with SafePoint Storm Vinyl Double Hung Limits of Use Certification Agency Certificate I Approved for use in HVHZ:No FL5419 R11 C CAC 42-19 DH Impact 36x63 RSO.pdf, Approved for use outside HVHZ:Yes FL5419 R11 C CAC 42-19 DH Impact 36x74 R50.odf Impact Resistant:Yes FL541.9 R11 C CAC'42-19 DH Impact 38x72 R50.pdf I Design Pressure:+50/-50 Quality Assurance Contract'Expiration Date Other:36 x 63,36 x 74 and 38 x 72-.Missile Impact 09/14/2016 Rating: C Installation Instructions FL5419 R11 II IN0540-R2.pdf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5419 R11 AE EvalRevort IN0540-R2.pdf Created by Indepe dent Th'Sd Party:Yes ' 5419.4 42-19 ProFlnish Brickmo Sak%ftnt brm yl - ae, Hung Twin Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL5419 R11 C CAC 42-19 DH Twin Impact 73x74 1150.ndf Approved for use outside HVHZ.:Yes Quality Assurance Contract Expiration Date i Impact Resistant:Yes 09/14/2016 Design Pressure:+50/-50 Installation Instructions Other:73 x 74—Missile Impact Rating:C FL5419 R11 II IN0550 42-19 Impact DH Twin 2X.pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGEVXQwtDgtHJPwMo6eH... 5/18/2015 i Florida Building Code Onlir:� Page 1 of 1 t-.-46 �'.�I:�r£-,e4a i L-ida mlI'pntIf BCIS Home i Log In I User Registration Hot TOPICS Submit Surcharge ! Stats&Fads Publications j FBC Staff I BCIS Site Map `Links Ip Search. Bushes ) Professir al use Public User Approval Regulation Product Aooroval Menu>Product or Aooiication Search>Application List INS- , Search Criteria Refine Search k Code'Version 2010 FL# 5419 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status, ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,.Number or Name ALL Product Description ALL j Approved for use in HVHZ ALL Approved for use outside HVHZ ALL 'Impact Resistant ALL Design Pressure ALL Other ALL 1 Search Results.-App lications ; FL# Type Manufacturer Validated By Status FL5419-R11 Revision Simonton Windows American Architectural Manufacturers Association Approved -Histo Category:Windows (214)878-1642 Subcategory:Double Hung *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::1940 North Monroe Street,Tallahassee FL 77399 Phone:850-487-1824. i The State of Florida is an AA/EEO employer.Copyright 2007-2013-State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to apublic-records request,do not send; electronic mall to this entity.Instead,Contact the office by phone or by traditional'mall.If you have any questions,please contact 850.487.1395.-'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an emal:address if I they have one.The emails provided may be used for official communication with the licensee.:However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under i Chapter455,F.S.,please clicWhere. Product Approval Accepts: sccuritvm.vi a wt I t 3 t i f i E Ik r6� t }I i i 7 t https://www.floridabuilding.org/pr/pr app_lst.aspx 5/18/2015 f y�, yr�,. R R"SIa+S: EHSED' Ate NOTES: �pG:•�\GENS�c•+.�7.�i�� 9/115/2014, 2 "ADDED 37 z 78 PER LEST REPORT 895202_.0 T.D.Qe�•OJ26"rt!) 1. This installation has been evaluated for use in locations,adhering .to, the Texas & Florida Building Codes �vr No 58201 '�r'1: LUCAS A TURNER, P.E. 3 A �. - T.DD ,_ as/1a and where,pressure requirements as determined, by ASCE 7 Minimum Design Loads for Buildings and FL PE #.58201 Other Structures do not exceed the design pressure ratings.herein, far use outside the H.V.H.Z, a*: * :*^ TURNER.ENGINEERING k 4 ADDED GLAZING DETAILS AND FLASHING NOTE r.D za/11 2. All interior and exterior perimeter surfaces of the window must be caulked. =-a: :at CONSULTING, INC. s ro.o. *-M.!,3. Anchor type, size, spacing, and embedment shall be as specified in these drawings. X90: srgTE of :wtz39A�ABA21teA77Av)E s UDPATED SZES PER NEW)ESI NC. T.,' 124. Anchor embedment to substrate shall be beyond wall dressing or stucco. For concrete/CMU openings '�.��SFC 10P ��A� NPH. 9PPOR, FIL 167487UOPAh�I FOR MOLT PLE SI aSTRAIE TYPES embedment outflled CMU may includeood bucks, if butdo not require 1xd into woodbuckstbetweentprodlons to uct and substrate. In tallations � s/ONA�� � ` g y q P r+++antltt Lucas A Tumor E" to hollow CMU require the use of 1x bucks between product and substrate. 201409-1516:00-04:OD .+ 5. Wood or masonry openings, bucks, and buck fasteners, by others, shall be properly designed and installed to transfer wind loads to"the structure. Substrates shall meet the minimum 'strength requirements as shown in o Table 1, this sheet. Concrete or masonry substrates shall not be cracked. 6. The responsibility for selection of Simonton products to meet ony applicable local laws, building codes, .500" GLAZING cDMPouN❑ t f ordinances, or other safety requirements rests solely with the architect, building owner, or contractor. GLASS BITE (PECORA 896-HIS) Shims are requiredwhere gaps of greater than 1/16" exist between opening and frame. Max. shim stack is 1/8'ANNEALED 1/4". Shims shall be load-bearing and capable of transferring loads to the substrate. 0.105 PVe(SOLuT1A) When used in areas, requiring impact protection, this product DOES NOT REQUIRE the use of approved I'mpact resistant shutters or.other external protection, IU( _�—1/8'ANNEALED 9. Seling and flashing by others should be applied using the ASTM E 2112 methodology appropriate for the 7 opening into which the door is being installed. Overall water penetration resistance of the installed product ❑ ❑ '�AIR SPACE is the responsibility of others. r —] " 1/8'TEMPERED 10. Glazing shall comply with ASTM E 1300-04 11. For instellat(an to metal substrates, anchors shall be long enough to be fully threaded through the metal thickness with an additional 3/16" min. of threads beyond. SPACER 12. A minimum center-to-center spacing of 1-1/4" shall be maintained between all Elco Ultracons in any 1" INSULATED TEMPERED/ANNEALED IMPACT GLASS direction. 13. All fasteners penetrating into pressure treated wood shall be capable of preventing corrosion due to reaction WITH 0.105" PVB INTERLAYER with pressure treatment chemicals. Any dissimilar materials that come into contact shall be protected to 37" X 76" AND 53" X'76" DOUBLE HUNG(OPTIONAL) prevent reactions in accordance with code requirements. 14. A wind Toad duration factor Cd = 1.6 was used for the analysis of wood screws only. 15. Windows shall be constructed as specified in test reports C7745.01-109-47-r0, 00296.01-501-47-r0, D0962.01-501-47-r0, D0963.01-501-47-r0, D0964,01-501-47-r0, and D0965.01-501-47-r0 by o Architectural Testing, Inc. .500° GLAZING COMPOUND GLASS BITE (PECORA,896-HIS) 1/8'ANNEALED TABLE 1: INSTALLATION FASTENERS TABLE 0.090 PVB(SOLUTIAj L ANCHOR TYPE MIN. EMBED MIN. EDGE DIST. 1/8"ANNEALED CONCRETE (2.85 KSI MIN.). 3/16' ELCO ULTRACON 1" 1" HO 0 GROUT-FI EO CMU 3/16' ELCO ULTRACON 1-1/4" 2 1/2" ❑ 0 �l AIR DACE ASTM C90 2X MIN. SOUTHERN PINE WOOD 3/16' ELCO ULTRACON 1-3/8" 3/4" f� 1/6"TEMPERED G=0.55 l�JI 2X MIN. SOUTHERN PINE WOOD #10 WOOD SCREW 1-3/8" 3/4" _ G=0.55 SPACER E I19-GAUGE 0.060 MIN. STEEL 1310-15 ITW TEK5 SEE NOTE 11 1/2" STUD 33KSI YIELD MIN. SELF-ORILUNG SCREW F 1,11/6 ALUM. 6063-TS MIN. OR 16 GRADE 5 SELF-TAPPING SEE NOTE 17 1/2" 1" INSULATED TEMPERED 0,090" PVQINTLED IMPACT GLASS 8" STEEL 36 KSI MIN_ DRILLING SCREW WITH O.a90" PVB INTERLAYER 37" X 84" DOUBLE HUNG (OPTIONAL) DISC"a__L0 Re�_�_STATEMENT / SIMONTON� 8 IN0364 7' Thi.4—ant to the property or S'enanton Window,,+.hIch Dimensional,Tolaranees g 8 A retain A propA tcry"and othe,dghta to It, blcct matter, Ilnieea Otherwlee SoaciRed TTT T.0.0. n/t3/CB This doaumenf.le.ProNded to,tha recipient on the cn—.,ed _ 1 Cochranc.lvrnuo GNEOtED BY:DA1E: d,Uon that It id not to be dndosed,reproduced 6 ande or Pmnsbmo,WV 26415 port,nor.rod in conluiction with the design,manufacture or Decimals. Angles SCALE: SHEET. APPR D BY;DATE: ma oV of goads far anire other than Simonton Wind.- FlT Z of 2 .Ithoul Itn eonomL� Thle rmtriellon dooa not Iimi!the %f.03 � exiplentb righla to Win Information contained In this %X i:.01 a' 30 min. 07-09/07-1D/07-20 IMPACT 00lIBlE HUNG dowment Mddr la properly obtained from anolhar source• .%X%f.005 _ n1LE FlLE:INaM4 IN ANcHOR TABLE,. A OPTIONAL GLAZING DETAILS