HomeMy WebLinkAboutProject Information File No.: 56-0180856-002
File Name:Eberle,Glenn and Mary Ann
Page 2 of 5
or rules governing the exempt activity. In the event you need to re-verify the exempt status for the
activity after the one-year expiration of this verification,a new application and verification fee will
be required. Any substantial modifications to the project design should be submitted to the
Department for review,as changes may result in a permit being required.Conditions of compliance
with the regulatory exemption are contained in Attachment A.
2. Proprietary Review—NOT REQUIRED
The activity does not appear to be located on sovereign submerged lands, and does not require
further authorization under chapter 253 of the Florida Statutes, or chapters 18-20 or 18-21 of the
Florida Administrative Code.
3. Federal Review—SPGP APPROVED
Your proposed activity as outlined on your application and attached drawings qualifies for Federal
authorization pursuant to the State Programmatic General Permit IV-R1, and a SEPARATE
permit or authorization will not be required from the Corps. Please note that the Federal
authorization expires on July 25, 2016. You, as permittee, are required to adhere to all General
Conditions and Special conditions that may apply to your project." A copy of the SPGP IV-Rl
with all terms and conditions and the General Conditions may be found at
http://www.sai.usace.aKMy.mil/Divisions/Re ug latory/sourcebook.htm.
Authority for review - an agreement with the USACOE entitled "Coordination Agreement
Between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of
Environmental Protection, or Duly Authorized Designee, State Programmatic General Permit",
Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water Act.
Additional Information
Please retain this letter. The activities may be inspected by authorized state personnel in the future
to insure compliance with appropriate statutes and administrative codes. If the activities are not
in compliance,you may be subject to penalties under Chapter 373,F.S.,and Chapter 18-14,F.A.C.
NOTICE OF RIGHTS
This action is final and effective on the date filed with the Clerk of the Department unless a petition
for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the
deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not
be final and effective until further order of the Department. Because the administrative hearing
process is designed to formulate final agency action, the filing of a petition means that the
Department's final action may be different from the position taken by it in this notice.
Petition for Administrative Hearing
A person whose substantial interests are affected by the Department's action may petition for an
administrative proceeding(hearing)under Sections 120.569 and 120.57,F.S. Pursuant to Rule 28-
106.201, F.A.C., a petition for an administrative hearing must contain the following information:
(a) The name and address of each agency affected and each agency's file or
identification number, if known; .
QQ�01EmON FLORIDA DEPARTMENT OF RICK SCOTT
GOVERNOR
f ENVIRONMENTAL PROTECTION
CARLOS LOPEZ
-CANTERA
ofa SOUTHEAST DISTRICT BRANCH OFFICE LT.GOVERNOR
R1 337 NORTH U.S.HIGHWAY 1,SUITE 307
FORT PIERCE,FL 34950 JONATHAN P.STEVERSON
77 (772)467-5500 SECRETARY
March 25, 2015 ST- 0 BDII�ING DIVISION
REVIEWED FOR CO CE � ` cca- -
REVIEW II'Y
IRATE - ►'1.f. c Oil n: r�EQ,
Glenn and Mary� V E MUST BE k7EPT ON JOB $ .-�
65 Aqua Ra DriVeOR NO INSPECTION WILL BE MADE. c':,OiblT oh
Jensen Beach, FL 34957 SIDES
Sent via e-mail: glenn@cespecialist.com
N
Re: File No.: 56-0180856-002 ; VM
File Name: Eberle, Glenn and Mary Ann TECH
Dear Mr. and Mrs. Eberle:
On February 23, 2015, we received your application for an exemption to perform the following
activities: (1) construct a 210 sq. ft. dock consisting of a 15' x 4' (60 sq. ft.) access walkway and
a 15' x 10' (150 sq. ft.) terminal platform and (2) install a boatlift. The project is located in a
manmade canal, Class III Waters, adjacent to 65 Aqua Ra Drive, Jensen Beach (Section 11,
Township 37 South, Range 41 East), in St. Lucie County (Latitude N 27° 15' 52.00", Longitude
W 80° 12' 23.00").
Your request has been reviewed to determine whether it qualifies for(1)regulatory exemption, (2)
proprietary authorization (related to state-owned submerged lands), and (3) federal approval that
may be necessary for work in wetlands or waters of the United States.
Your project qualifies for all three. However, this letter does not relieve you from the
responsibility of obtaining other federal, state, or local authorizations that may be required for the
activity.
1. Regulatory Review-VERIFIED
Based on the information submitted, the Department has verified that the activity as proposed is
exempt under Chapter 62-330.051(5)(b), Florida Administrative Code, from the need to obtain a
regulatory permit under part IV of Chapter 373 of the Florida Statutes.
This exemption verification is based on the information you provided the Department and the
statutes and rules in effect when the information was submitted. This verification will expire after
one year, and will not be valid at any other time if site conditions materially change, the project
design is modified, or the statutes or rules governing the exempt activity are amended. However,
the activity may still be conducted without further notification to or verification from the
Department after the one-year expiration of this verification, provided: 1) the project design does
not change; 2) site conditions do not materially change; ) re Lo c t t
.a
www.dep.statefl.us
File No.: 56-0180856-002
File Name:Eberle,Glenn and Mary Ann
Page 3 of 5
(b) The name,address,any email address,any facsimile number,and telephone number
of the petitioner; the name, address, and telephone number of the petitioner's
representative, if any, which shall be the address for service purposes during the course of
the proceeding; and an explanation of how the petitioner's substantial interests are or will
be affected by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none, the petition
must so indicate;
(e) A concise statement of the ultimate facts alleged, including the specific facts that
the petitioner contends warrant reversal or modification of the agency's proposed action;
(f) A statement of the specific rules or statutes that the petitioner contends require
reversal or modification of the agency's proposed action, including an explanation of how
the alleged facts relate to the specific rules or statutes; and
(g) A statement of the relief sought by the petitioner, stating precisely the action that
the petitioner wishes the agency to take with respect to the agency's proposed action.
The petition must be filed (received by the Clerk) in the Office of General Counsel of the
Department at 3900 Commonwealth Boulevard,Mail Station 35,Tallahassee,Florida 32399-3000.
Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the
time of filing.
Time Period for Filing a Petition
In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the
applicant must be filed within 21 days of receipt of this written notice. Petitions filed by any
persons other than the applicant, and other than those entitled to written notice under Section
120.60(3),F.S.must be filed within 21 days of publication of the notice or within 21 days of receipt
of the written notice, whichever occurs first. Under Section 120.60(3), F.S., however, any person
who has asked the Department for notice of agency action may file a petition within 21 days of
receipt of such notice,regardless of the date of publication. The failure to file a petition within the
appropriate time period shall constitute a waiver of that person's right to request an administrative
determination(hearing)under Sections 120.569 and 120.57,F.S.,or to intervene in this proceeding
and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another
party) will be only at the discretion of the presiding officer upon the filing of a motion in
compliance with Rule 28-106.205,F.A.C.
Extension of Time
Under Rule 62-110.106(4), F.A.C., a person whose substantial interests are affected by the
Department's action may also request an extension of time to file a petition for an administrative
hearing. The Department may, for good cause shown, grant the request for an extension of time.
Requests for extension of time must be filed with the Office of General Counsel of the Department
at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, before the
applicable deadline for filing a petition for an administrative hearing. A timely request for
extension of time shall toll the running of the time period for filing a petition until the request is
acted upon.
File No.:56-0180856-0U; -'
File Name:Eberle,Glenn and Mary Ann
Page 4 of 5
Mediation
Mediation is not available in this proceeding.
FLAWAC Review
The applicant, or any parry within the meaning of Section 373.114(1)(a) or 373.4275, F.S., may
also seek appellate review of this order before the Land and Water Adjudicatory Commission
under Section 373.114(1) or 373.4275, F.S. Requests for review before the Land and Water
Adjudicatory Commission must be filed with the Secretary of the Commission and served on the
Department within 20 days from the date when the order is filed with the Clerk of the Department.
Judicial Review
Any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by
filing a Notice of Appeal pursuant to Rules 9.110 and 9.190,Florida Rules of Appellate Procedure,
with the Clerk of the Department in the Office of General Counsel, 3900 Commonwealth
Boulevard,M.S. 35,Tallahassee,Florida 32399-3000;and by filing a copy of the Notice of Appeal
accompanied by the applicable filing fees with the appropriate District Court of Appeal. The
Notice of Appeal must be filed within 30 days from the date this action is filed with the Clerk of
the Department.
Thank you for applying to the Submerged Lands and Environmental Resource Permit Program. If
you have any questions regarding this matter,please contact Mary Zavash at the letterhead address
or at(772) 467-5566 or by email at MgU.Zavash@dep.state.fl.us
Executed in Palm Beach County, Florida.
STATE OF FLORIDA DEPARTMENT
OF ENVIRONMENTAL PROT CTION
enny Luddike
Environmental Administrator
Submerged Lands and Environmental
Resource Program
Enclosures:
Attachment A- Specific Exemption Rule
Attachment B-Newspaper Publication
General Conditions for the use of the Federal SPGP IV-Rl
Project Drawings, 4 pages
Copies furnished to:
Mary Zavash,FDEP, mary.zavash@dep.state.fl.us
USACOE- Palm Beach Gardens,FDEP-SP@usace.army.mil
Danna Small, DLS Environmental Services, Inc., danna@DLSenvironmentalservices.com
File No.:56-0180856-002
s
File Name:Eberle,Glenn and Mary Ann
Page 5 of 5
CERTIFICATE OF SERVICE
The undersigned duly designated deputy clerk hereby certifies that this determination,
including all copies, was mailed before the close of business on 3/25/15 , to the above
listed persons.
FILING AND ACKNOWLEDGMENT
FILED, on this date,pursuant to 120.52(9),
Florida Statutes, with the designated Department
Clerk, receipt of which is hereby acknowledged.
P&MCk"'5
/25/15
Clerk Date
Oculus:ERP/Permitting Authorization/ERP 180856/Permit Final/ERP Exemption-EE/002
Attachment A
Chapter 62-330.051 Exempt Activities.
The activities meeting the limitations and restrictions below are exempt from permitting. However,
if located in, on, or over state-owned submerged lands, they are subject to a separate authorization
under Chapters 253 and 258, F.S., and Chapters 18-18, 18-20, and 18-21, F.A.C., as applicable.
(5) Dock, Pier, Boat Ramp and Other Boating-related Work—
(b)Installation of private docks,piers,and recreational docking facilities, and installation of local
governmental piers and recreational docking facilities,in accordance with Section 403.813(1)(b),F.S.
This includes associated structures such as boat shelters,boat lifts, and roofs,provided:
1. The cumulative square footage of all structures located over wetlands and other surface waters
does not exceed the limitations in Section 403.813(1)(b), F.S.;
2.No structure is enclosed on more than three sides with walls and doors;
3. Structures are not used for residential habitation or commercial purposes,or storage of materials
other than those associated with water dependent recreational use; and
4. Any dock and associated structure shall be the sole dock as measured along the shoreline for a
minimum distance of 65 feet, unless the parcel of land or individual lot as platted is less than 65 feet
in length along the shoreline, in which case there may be one exempt dock allowed per parcel or lot.
C2
Attachment B File No.: 56-0180856-002
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
NOTICE OF DETERMINATION OF EXEMPTION
The Department of Environmental Protection gives notice that the project to (1) construct a 15' x 4' (60 sq. ft.) access
walkway;(2)construct a 15'x 10' (150 sq. ft.)terminal platform for a total docking structure of 210 sq.ft.; (3)install a boatlift has
been determined to be exempt from requirements to obtain an Environmental Resource Permit. The project is located in a manmade
canal, Class III Waters,adjacent to 65 Aqua Ra Drive,Jensen Beach(Section 11,Township 37 South,Range 41 East),in St. Lucie
County(Latitude N 27° 15' 52.00",Longitude W 80° 12'23.00").
A person whose substantial interests are affected by the Department's action may petition for an administrative proceeding
(hearing)under sections 120.569 and 120.57 of the Florida Statutes. The petition must contain the information set forth below and
must be filed(received by the clerk) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail
Station 35,Tallahassee,Florida 32399-3000.
Mediation is not available.
If a timely and sufficient petition for an administrative hearing is filed, other persons whose substantial interests will be
affected by the outcome of the administrative process have the right to petition to intervene in the proceeding. Intervention will be
permitted only at the discretion of the presiding officer upon the filing of a motion in compliance with rule 28-106.205 of the Florida
Administrative Code.
In accordance with rule 62-110.106(3), F.A.C., petitions for an administrative hearing must be filed within 21 days of
publication of the notice or receipt of written notice,whichever occurs first. Under rule 62-110.106(4)of the Florida Administrative
Code, a person whose substantial interests are affected by the Department's action may also request an extension of time to file a
petition for an administrative hearing.The Department may,for good cause shown,grant the request for an extension of time. Requests
for extension of time must be filed with the Office of General Counsel of the Department at 3900 Commonwealth Boulevard,Mail
Station 35, Tallahassee, Florida 32399-3000 prior to the applicable deadline. A timely request for extension of time shall toll the
running of the time period for filing a petition until the request is acted upon. Upon motion by the requesting party showing that the
failure to file a request for an extension of time before the deadline was the result of excusable neglect,the Department may also grant
the requested extension of time.
The petitioner shall mail a copy of the petition to the applicant at the address indicated above at the time of filing. The failure
of any person to file a petition for an administrative hearing within the appropriate time period shall constitute a waiver of that right.
A petition that disputes the material facts on which the Department's action is based must contain the following information:
(a) The name and address of each agency affected and each agency's file or identification number,if known;
(b) The name,address,and telephone number of the petitioner;the name,address,and telephone number of the petitioner's
representative,if any,which shall be the address for service purposes during the course of the proceeding;and an explanation of how
the petitioner's substantial interests are or will be affected by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none,the petition must so indicate;
(e) A concise statement of the ultimate facts alleged,including the specific facts the petitioner contends warrant reversal or
modification of the agency's proposed action;
(f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency's
proposed action;and
(g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to
take with respect to the agency's proposed action.
A petition that does not dispute the material facts on which the Department's action is based shall state that no such facts are
in dispute and otherwise shall contain the same information as set forth above,as required by rule 28-106.301.
Under sections 120.569(2)(c)and(d)of the Florida Statutes,a petition for administrative hearing shall be dismissed by the
agency if the petition does not substantially comply with the above requirements or is untimely filed.
Complete copies of all documents relating to this determination of exemption are available for public inspection during
normal business hours, 8:00 a.m.to 5:00 p.m.,Monday through Friday, at the Southeast District office,3301 Gun Club Road,MSC
7210-1,West Palm Beach,Florida 33406.
GENERAL CONDITIONS FOR FEDERAL AUTHORIZATION FOR SPGP IV-Rl
1. The time limit for completing the work authorized ends on July 25, 2016.
2. You must maintain the activity authorized by this permit in good condition and in conformance
with the terms and conditions of this permit. You are not relieved of this requirement if you abandon
the permitted activity, although you may make a good faith transfer to a third party in compliance
with General Condition 4 below. Should you wish to cease to maintain the authorized activity or
should you desire to abandon it without a good faith transfer,you must obtain a modification of this
permit from this office,which may require restoration of the area.
3.If you discover any previously unknown historic or archeological remains while accomplishing the
activity authorized by this permit, you must immediately notify this office of what you have found.
We will initiate the Federal and State coordination required to determine if the remains warrant a
recovery effort or if the site is eligible for listing in the National Register of Historic Places.
4. If you sell the property associated with this permit, you must obtain the signature and mailing
address of the new owner in the space provided below and forward a copy of the permit to this office
to validate the transfer of this authorization.
5. If a conditioned water quality certification has been issued for your project,you must comply with
the conditions specified in the certification as special conditions to this permit.
6. You must allow representatives from this office to inspect the authorized activity at any time
deemed necessary to ensure that it is being or has been accomplished in accordance with the terms
and conditions of your permit.
Further Information:
1. Limits of this authorization.
a. This permit does not obviate the need to obtain other Federal, State, or local authorizations
required by law.
b. This permit does not grant any property rights or exclusive privileges.
c. This permit does not authorize any injury to the property or rights of others.
d. This permit does not authorize interference with any existing or proposed Federal projects.
2. Limits of Federal Liability. In issuing this permit, the Federal Government does not assume any
liability for the following:
a.Damages to the permitted project or uses thereof as a result of other permitted or unpermitted
activities or from natural causes.
b. Damages to the permitted project or uses thereof as a result of current or future activities
undertaken by or on behalf of the United States in the public interest.
c. Damages to persons, property, or to other permitted or unpermitted activities or structures
caused by the activity authorized by this permit.
d.Design or Construction deficiencies associated with the permitted work.
e. Damage claims associated with any future modification, suspension, or revocation of this
permit.
3. Reliance on Applicant's Data: The determination of this office that issuance of this permit is not
contrary to the public interest was made in reliance on the information you provided.
4.Reevaluation of Permit Decision: This office may reevaluate its decision on this permit at any time
the circumstances warrant. Circumstances that could require a reevaluation include, but are not
limited to,the following:
a. You fail to comply with the terms and conditions of this permit.
b. The information provided by you in support of your permit application proves to have been
false, incomplete, or inaccurate (see 3 above).
c. Significant new information surfaces which this office did not consider in reaching the
original public interest decision.
5. Such a reevaluation may result in a determination that it is appropriate to use the suspension,
modification, and revocation procedures contained in 33 CFR 325.7 or enforcement procedures such
as those contained in 33 CFR 326.4 and 326.5. The referenced enforcement procedures provide for
the issuance of an administrative order requiring you comply with the terms and conditions of your
permit and for the initiation of legal action where appropriate. You will be required to pay for any
corrective measures ordered by this office, and if you fail to comply with such directive, this office.
may in certain situations (such as those specified in 33 CER 209.170) accomplish the corrective
measures by contract or otherwise and bill you for the cost.
6. When the structures or work authorized by this permit are still in existence at the time the property
is transferred,the terms and conditions of this permit will continue to be binding on the new owner(s)
of the property. To validate the transfer of this permit and the associated liabilities associated with
compliance with its terms and conditions,have the transferee sign and date below.
(TRANSFEREE-SIGNATURE) (DATE)
(NAME-PRINTED)
(ADDRESS)
STANDARD MANATEE CONDITIONS FOR IN-WATER WORK
2011
The permittee shall comply with the following conditions intended to protect manatees from direct
project effects:
a. All personnel associated with the project shall be instructed about the presence of
manatees and manatee speed zones, and the need to avoid collisions with and injury to
manatees. The permittee shall advise all construction personnel that there are civil and
criminal penalties for harming, harassing, or killing manatees which are protected under
the Marine Mammal Protection Act,the Endangered Species Act, and the Florida Manatee
Sanctuary Act.
b. All vessels associated with the construction project shall operate at"Idle Speed/No Wake"
at all times while in the immediate area and while in water where the draft of the vessel
provides less than a four-foot clearance from the bottom. All vessels will follow routes of
deep water whenever possible.
c. Siltation or turbidity barriers shall be made of material in which manatees cannot become
entangled, shall be properly secured, and shall be regularly monitored to avoid manatee
entanglement or entrapment. Barriers must not impede manatee movement.
d. All on-site project personnel are responsible for observing water-related activities for the
presence of manatee(s). All in-water operations, including vessels, must be shutdown if a
manatee(s) comes within 50 feet of the operation. Activities will not resume until the
manatee(s) has moved beyond the 50-foot radius of the project operation, or until 30
minutes elapses if the manatee(s) has not reappeared within 50 feet of the operation.
Animals must not be herded away or harassed into leaving.
e. Any collision with or injury to a manatee shall be reported immediately to the FWC Hotline
at 1-888-404-3922. Collision and/or injury should also be reported to the U.S. Fish and
Wildlife Service in Jacksonville (1-904-731-3336) for north Florida or Vero Beach (1-772-
562-3909) for south Florida, and to FWC at ImperiledSpecies@myFWC.com
f. Temporary signs concerning manatees shall be posted prior to and during all in-water
project activities. All signs are to be removed by the permittee upon completion of the
project. Temporary signs that have already been approved for this use by the Florida Fish
and Wildlife Conservation Commission (FWC) must be used (see MyFWC.com/manatee).
One sign which reads Caution:Boaters must be posted. A second sign measuring at least
81/2" by 11" explaining the requirements for"Idle Speed/No Wake" and the shut down of
in-water operations must be posted in a location prominently visible to all personnel
engaged in water-related activities. Questions concerning these signs can be sent to the
email address listed above.
CAUTION : MANATEE HABITAT
All project vessels
IDLE SPEED / NO WAKE
When a manatee is within 50 feet of work
all in-water activities must
SHUT DOWN
Report any collision- with or injury to a manatee;
Wildlife Alert:
1-888-404-FW00(3922)
cell *"FVVC or #FWC
stir%
UNITED STATES DEPARTMENT OF COMMERCE
,�EKTapea National Oceanic and Atmospheric Administration
apps NATIONAL MARINE FISHERIES SERVICE
a Southeast Regional Office
263 13th Avenue South
St.Petersburg,FL 33701
S?XrE9 OTP
SEA TURTLE AND SMALLTOOTH SAWFISH CONSTRUCTION CONDITIONS
The permittee shall comply with the following protected species construction conditions:
a. The permittee shall instruct all personnel associated with the project of the potential presence of
these species and the need to avoid collisions with sea turtles and smalltooth sawfish. All
construction personnel are responsible for observing water-related activities for the presence of
these species.
b. The permittee shall advise all construction personnel that there are civil and criminal penalties for
harming, harassing, or killing sea turtles or smalltooth sawfish, which are protected under the
Endangered Species Act of 1973.
c. Siltation barriers shall be made of material in which a sea turtle or smalltooth sawfish cannot
become entangled, be properly secured, and be regularly monitored to avoid protected species
entrapment. Barriers may not block sea turtle or smalltooth sawfish entry to or exit from designated
critical habitat without prior agreement from the National Marine Fisheries Service's Protected
Resources Division, St. Petersburg,Florida.
d. All vessels associated with the construction project shall operate at "no wake/idle" speeds at all
times while in the construction area and while in water depths where the draft of the vessel provides
less than a four-foot clearance from the bottom. All vessels will preferentially follow deep-water
routes(e.g.,marked channels)whenever possible.
e. If a sea turtle or smalltooth sawfish is seen within 100 yards of the active daily
construction/dredging operation or vessel movement, all appropriate precautions shall be
implemented to ensure its protection. These precautions shall include cessation of operation of any
moving equipment closer than 50 feet of a sea turtle or smalltooth sawfish. Operation of any
mechanical construction equipment shall cease immediately if a sea turtle or smalltooth sawfish is
seen within a 50-ft radius of the equipment. Activities may not resume until the protected species
has departed the project area of its own volition.
£ Any collision with and/or injury to a sea turtle or smalltooth sawfish shall be reported immediately
to the National Marine Fisheries Service's Protected Resources Division (727-824-5312) and the
local authorized sea turtle stranding/rescue organization.
g. Any special construction conditions, required of your specific project, outside these general
conditions, if applicable, will be addressed in the primary consultation.
Revised:March 23, 2006
O:\forms\Sea Turtle and Smalltooth Sawfish Construction Conditions.doc
..n AIME p,
Y $
G.fo e*EQy
f 4gTMENT
1 t
1t -
PROJECT;SITE -
ark
•x \ � + Savannas Sta{e ,
T =L U C 1'E
SE Watton Rd i ti,t
ata ' \ rain, A t I a t� t
� 1
y� O c e:aa
t 5 u tl
F LO fR I`'D A _ —�—
,n. t4 x Nbrih Perk.St
\� $Lurie Rever _ - -aBeach,. �
•; 1 r Aquatic,Prescry i._"
Ocean 56-0180056-002
t ,
- 7v7n tC Breeze Park \
r G1 an&11�a Aiut Eberle
rfla:
1 North
ry ,
wver f
Shores 723 �YCpi111 Q17�1911L
` } Manmade canal
srb r Rd f
Rid 1
: x
_ , tt
steam._ y e:March 23,2075 r '�
AIA
i 4
�T t 76 .a t 10tH 'S Witham Feld
1 of 4
ST. LUCI E COUNTY O``=- -s-� .
- : yj
f P�
PROJECT SITE`
l ,
_ A t I a n. -t, t .c
'! n d i -a n - s Wnvel - O c- e a rY'
-
- - -
�,•`, r Aqua-R Dr �E -
Jensen Beach 1 _
j\
C} O - s Jensen __6h_
h Causeway7--
-A
-----
SECTION 11,TOWNSHIP 37 SOUTH, RANGE 41 EAST
]Environmental Location Map
Glenn & Mary Ann Eberle
Inc.Services, 65 Aqua Ra Drive
1901 SIN Yellowtail Avenue Jensen Beach, Florida
Port Saint Lucie,FL 34953
PCM#4511-815-0007-000-2
Phone:772-216-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE:
N.T.S. FEB 2015 SHEET 1 of 4
F.R,
a3.. .a
a W—
;Z--
7
,� ^ r • ts��ik+ s' }�r�N#��$���a �� $�Jr �;+.;n )�:q��.=a f3Y yql, � '���r� °
s r4 r s� s� i 7 1 •� lS I
f f. X31
*1�
t 'sg ;,r3 VSs e �k)r �} � T
� J i
o
99
#
WN
77
NU
fr -SUB:I,ECT x, FSI .r
`PROPERTY - ,.
sn
e
56-0180856-002 y
Glom&Mary Am Eberle
Dockbeafft
Manmadecanal
Da#e:Manch 23,2015
ti- 2 Of 4 y, Aerial
EnviLr®r i a: ],
_ Glenn & Mary Ann Eberle
Services, ----"
r - --'`� 65 Aqua Ra Drive
1901 SUV Yellowtail Avenue Jensen Reach, Florida
Port Saint Lucie,FL 34953
PCR!#4511-815-0007-000-2
Phone:772-215-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE:
N.T.S. FEB 2015 SHEET 2 of 4
01
MANMADE BASIN
WATERBODY WIDTH 360±
APPROXIMATE
APPROXIMATE '
i �
i
RIPARIAN LINE RIPARIAN LINE i
i
i
PROPOSED APPROXIMATE
i BOATLIFT MEAN HIGH WATER LINE i
- -.-.- - - - - - - - ......------------------i
3'
.-.-.-.-.-.-.-.-.-. .-.-.-.-.-.-.
10'
I �
i
' RETAINING WALL i
i 15' MANGROVES
t '
i
i -.-.-.-.- .-.-.-.-.-.-.-.-.-i
-2'
-2 --------------------- .-.-.-.- .-.-.
-.
,
15' '
i
I4
SHORELINE LENGTH
210 L.F.
5 -01 80856-0026
14t� &NhU AmEherle ekiboaM
m
M nmadecanal ra'
I
\6 Date: lvlar i%2015
sy:*x cams
Sheet:
NOTES: 4 -y 3 of 4
1. ELEVATION DATUM IS MLW
MHW=-0.43 NAVD BB MLW=-1. D
2. PROPOSED DOCK TOTALS 210 SO. - �
3. NO SUBMERGED RESOURCES WITHIN PR !~1R _
4. DOCK HAS BEEN LOCATED TO AVOID MANGROVES MPAGT•S-`-''-
Environmental Proposed Plan View
is Glenn & Mary Ann Eberle
Inc.Services, I 65 Aqua Ra Drive
1901 SW Yellowtail Avenue Jensen Beach, Florida
Port Saint Lucie,FL 34953
PCN#4511-815-0007-000-2
Phone:772-216-3997 Fax:772-8794520
www.disenvironmentalservices.com SCALE:
1"=30' FEB 2015 SHEET 3 of 4
1S, , 15' NMI_
I ACCESS I PLATFORM
f
t
t
4.5'
s
MHW
MLW
2'+
MAN911gd€S' __
RETAINING WALL NSI
- �y_STI C
56-0180056-002791
�
Gleam&NIny Amr Eberle
l � IbckfbeaM � .
4y
Manm ad a canal 1
i Date:MaFch 23, 20:15 ,
sheet:
NOTES: 4 of 4
1. ELEVATION DATUM IS MLW _
MHW=-0.43 NAVD 88 MLW=-1.40 NAVD 88
2. PROPOSED DOCK TOTALS 210 SQ.FT. `Z.q
3. NO SUBMERGED RESOURCES WITHIN PROJECT AREA
Environmental Dock Cross Section View
Glenn & Mary Ann Eberle
Inc.S erviceS, I 65 Aqua Ra Drive
1901 SWYellowtail Avenue Jensen Beach, Florida
Port Saint Lucie,FL 34953
PCN#4511-815-0007-000-2
Phone:772-216-3997 Fax:772-879-4520
www.disenvironmentalservices.com FatF: �—
1 -51 FEB 2015 SHEET 4 of 4
er` X07 m "'PROJECT.-SITE'
-t SavanrsasStac
SE 1NaHon Rd l
jr'AIA Q t 18 Ir t
ea a C
F"L 0 R.1,'[). A
f i ,
w No th EdrF Sf f Jensen
_ t �
LucheP' -732
-
aav�.c Prt~ervr 4
per
•� ` 7,_07A 1•Breeze Park .^ , .
North
River t 1 u }
r Shores u
A*kd L
e1
•� j
'-F<`Sn� �t 7a 4^•.Ea t 1 DtfS-' 4l"flimn Field '. $ ;
ST. LUCIE COUNTY
Blvd 1 r
i
;PROJECTSITE
1 1 1A�
r.
j-
Aqua R L1r: `
..... .... ¢«
Jenaea Beach> L .•. ,,. K ............. _ • -
yjr01 ~/
iC� O oJensen-beach CVf-
auseway=
:1 1.5 IlJL( Y !• Ol 5�: a J -
SECTION 11,TOWNSHIP 37 SOUTH,RANGE 41 EAST
Environmental Location Map
isGlenn& Mary Ann Eberle
S ervices, T Inc. 65 Aqua Ra Drive
1901 SW Yellowtail Avenue Jensen Beach, Florida
Port Saint Lucie,FL 34953
PCN#4511-815-0007-000-2
Phone:772-216-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE
N.T.S. APRIL 2015
MANMADE BASIN
WATERBODY WIDTH 360#
i
APPROXIMATE APPROXIMATE
RIPARIAN LINE RIPARIAN LINE
i
PROPOSED
APPROXIMATE
BOATL
MEAN HIGH WATER LINE
(BY OTHERS)
i -----------*-,-,-*----- - -•-•-.-.f•-3'
10'
RETAINING WALL i
i 15' MANGROVES
.-.-.-.-.-.-.-.-.L.-2'
-2 ----------------------- -.-.-.-.-.-
i
15'
i
4I
SHORELINE LENGTH
210 L.F.
ApR `t 1 2015
u tY F
Ci
p n 7
� ^�5
,..NOTES- ��{�1-�"(%tic- f-L.
PROPOSED WORK IS TO CONSTRUCT A 210 SQ.FT.DOCK AND INSTALL A Bf! LIF�(�OA LIFT BY OTHERS)
DECK DESIGN LOADS TO MEET 2010 FBC: 5'C �U01, 0' 15' 30'
WIND LOAD AS PER ANSUASCE 7-10 SPEED=170 MPH
EXPOSURE=D
IMPORTANCE FACTOR=1.0 GRAPHIC SCALE
ALL DOCK PILES 9"0 PILES(2.50 CCA)-MIN.PENETRATION 8'INTO RIVER BOTTOM
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
BOAT LIFT PILES 10"0 PILES(2.50 CCA)-MIN.PENETRATION 8'INTO RIVER BOTTOM
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
OVERALL DOCK PLAN VIEW Paul Welch, Inc.
IQS Environmental 1984 SW Biltmore Street,# 14
Services Inc. Glenn& Mary Ann Eberle Port St. Lucie, FL 34984 /
1901 SW Yellowtail Avenue 65 Aqua Ra Drive APR 0 7 2015
Port Saint Lucie,FL 34953 Jensen Beach, Florida
PCN#4511-815-0007-000-2 Paul Welch, PE No. 29945
Phone:772-215-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE
1 =30 APRIL 2015 SHEET 1 of 4
i
10l
— 2" X 6"P.T.DECKING
2"X 8"P.T CROSS-TIE
7.5'O.C. (1)1/2"X 6°SS LAG BOLT
(TYP.) (TYP)PER STRINGER
TO PILE LOCATION
1
15'
i l
,?2"0.
(TYP) 2"X 8"P.T.STRINGERS
(1)5/8"SS THRU BOLT
(TYP)PER CROSS-TIE
9"0 ABOVE DECK
MARINE PILES
— 2"X 8°P.T.STRINGERS
19°O.Cj
(TYP)
4
2° X 6'P.T.DECKING
l
15'
2"X 8°P.T CROSS-TIE
7'O.C.
(TYP-)
I
1
8' 4' —►, WOOD
"*NOTES"** SEAWALL CAP_
-ALL 9"0 MARINE DOCK PILES- M1,I.PEN RATION V INTO RIVER BOTTOM 01 2' 4'
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
-2" X 6"P.T.DECKING NOT ALL SHOWN FOR CLARITY
-DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" GRAPHIC SCALE
-ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304(OR BETTER)SS
DOCK PLAN Paul Welch, Inc.
Environmental VIEW DETAIL 1984 SW Biltmore Street,# 14
u� S ervlCeS, Inc. Glenn& Mary Ann Eberle Port St. Lucie, FL 34984
1Drive Ra
1901 SW Yellowtail Avenue 65 Aqua A P R Q �12015
Port Saint Lucie,FL 34953 Jensen Beach, Florida
PCN#4511-815-0007-000-2 Paul Welch, PE No.29945
Phone:772-215-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE: �._
1 4 APRIL 2015E
HEET 2 of 4
I
4'
3'±
(1)1/2"X 6"SS LAG BOLT
(TYP)PER STRINGER
TO PILE LOCATION
4.5'±
(1)5/8"SS THRU BOLT
(TYP)PER CROSS-TIE
2"X 6" P.T.
/————————————— ————7-7———————
DECKING
MHW
2'X 8"P.T.STRINGER 1
19"O.C.(lYP) MLW
VARIES
2"X 8"P.T.CROSS-TIE
SUBSTRATE
9'0 MARINE PILINGS
"'NOTES•" 0' 1' 2'
ALL 9"0 MARINE DOCK PILES- MIN.PENETRATION V INTO RIVER BOTTOM _
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" GRAPHIC SCALE
-ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304(OR BETTER)SS
DOCK ACCESS Paul Welch, Inc.
Environmental CROSS SECTION VIEW 1984 SW Biltmore Street, 114
qSServices, 4 1Tn . Glenn&Mary Ann Eberle Port St. Lucie, FL 34984
1901 SW Yellowtail Avenue 65 A Ra Drive
Aqua APR 2015
Port Saint Lucie,FL 34953 Jensen Beach, Florida
PCN#4511-815-0007-000-2 Paul Welch, PE No.29945
Phone:772-215-3997 Fax:772-879-4520
www.disenvironmentalservices.com SCALE, "—
1 -2 APRIL 2015 SHEET 3 of 4
1'
10'
T
3'±
(1)1/2"X 6"SS LAG BOLT 4.5'±
(TYP)PER STRINGER
TO PILE LOCATION
(1)5/8°SS THRU BOLT
(TYP)PER CROSS-TIE
------------ -- ------------------- ------- ------------
-
-- -----------J
MLW
2"X 8"P.T.CROSS-TIE
VARIES
2"X 8"P.T.STRINGERS
22°O.C.(TYP.)
y,
SUBSTRATE
2"X6" P.T.
DECKING
9"0 MARINE PILINGS
`"NOTES`"
ALL 9"0 MARINE DOCK PILES- MIN. PENETRATION V INTO RIVER BOTTOM 0' 1.5' 3'
OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY
DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3" GRAPHIC SCALE
-ALL HARDWARE ON THE DECK AND BELOW TO BE GRADE 304(OR BETTER)SS
DOCK PLATFORM Paul Welch, Inc.
,is Environmental CROSS SECTION VIEW 1984 SW Biltmore Street, 114
Services, Inc. Glenn& Mary Ann Eberle Port St. Lucie, FL 34984
1901 SW Yellowtail Avenue 65 Aqua Ra Drive APR 0 -i2015
Port Saint Lucie,FL 34953 Jensen Beach, Florida
PCN#4511-815-0007-000-2 Paul Welch, PE No.29945
Phone:772-216-3997 Fax:772-879-4520 -7
www.disenvironmentalservices.com SCALE „_ ,
1 —3 APRIL 2015 SHEET 4 of 4
ENGINEERING REVIEW.
BOAT LIFT TOP CARRIER BEAMS AND NOTE TO EXAMINER:
MOUNTING BRACKETS COMPLY WITH THE THIS CERTIFIED ENGINEERED
ASCE/SEI 7-10, MINIMUM DESIGN DRAWING HAS BEEN PREPARED
LOADS INCLUDING WIND LOADS SPECIFICALLY FOR USE ONLY BY.•
F O R B U I L D I N G S A N D
OTHER STRUCTURES, THE 2010 FLORIDA
B U I L D I N G C 0 D E A N D -----------�—�—
THE 2010 ALUMINUM ASSOCIATION'S DESIGN
MANUAL— SPECIFICATIONS AS REQUIRED o°op0oo°o0oo°°°pOpO
BY THE FLORIDA BUILDING CODE. o°°°° R M
MOUNTED AS PER HI—TIDE INSTRUCTIONS, ;o° O� C E N
MOUNTING BRACKETS WILL EXCEED O
ULTIMATE DESIGN WIND SPEED OF 180 MPH o Q' NO.43855 p 'g
(EXPOSURE CATEGORY C OR D)
BOATS ARE TO BE REMOVED FROM BOAT o * r* 1
LIFTS PRIOR TO A MAJOR WIND EVENT. P
R Ea aPR i s
o STATE OF v�
PILINGS °°A% A, ORI D P ? 000
PILING PENETRATION TO BE 10' °°0 8 O °
INTO THE SAND BOTTOM OR 5' 0 OOOo s 1 O N A�. f�?000°o
I N T O R O C K STRATA ,
SUB—SURFACE CONDITIONS CAN
VARY GREATLY, THE CONTRACTOR
SHALL VERIFY ALL PILE
CAPACITIES TO COMPLY WITH
FBC 2010. ALL PILINGS TO BE ROOM BABM
8" MINIMUM DIAMETER PB'NO.
MCR2.5 C.C.A PRESSURE TREATED � ��
WOOD, PRE—STRESSED CONCRETE 8628 8W KANA8A AVE 8TUART,FL 34W7
OR COMPARABLE EQUIVALENT.
PILING MOUNTING TABS
MINIMUM (2) 3/8" DIA. SS LAG
BOLTS FOR WOOD PILING OR
SS CONCRETE ANCHORS FOR
CONCRETE PILINGS PER PILING
REQUIRED.MINIMUM (2) 3/8"
DIA. SS CARRIAGE BOLT FOR
ATTACHING MOUNTING TAB TO
LIFT REQUIRED PER PILING.
MOUNTING TAB CONSTRUCTED
ELECTRICAL REVIEW. FROM 1/4" X 2" ALUMINUM
1/2 HP ELECTRIC MOTOR 6061 — T6 FLAT BAR
8.8 AMPS 0 115V EACH
4.4 AMPS 0 230V EACH
QUANTITY 2
TOTAL WATTS. 2024
12 PW OLAPE POLES
it IsI
ToBUNK URAOM75 W NAROWARE �a
B ALLMNLW BUNKS OR CARPETED NOW BLMNS
° 2 V
L� 70WP NMAU? VLaEavaEe 'a 4,500 LB. CODA GEAR MM��L
BOAR/FTS AND MARINE PRODUCTS
° Err rzw cArurr x AsguBlr T Wa0 4050 SEL wTz ROAD
S 1 _TLI°ACKLE AssaBlr T BOA T LIFT
'f_;4'
ssp P„AE.,°, ; FORT PIERCE, FL 34981
i �ONME @T z R. HYDE SCALE. NT5 DATE• 2/12/13 REV.• 1 1-800-544-0735 www.hi—fide.com
DESmpim