Loading...
HomeMy WebLinkAboutDrawing 2015-05-12 19:31 isoprt75 7726927532 >> 0 P 7/9 Q) 1 i 0 PGT Industries NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. . Drawing No 4040-20, titled"Alum. Single Hung Window, Impact", sheets 1 through 11 of 11, dated 09/01/2005, with revision "D" dated 10/07/2011, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. B. TESTS 1. Test reports on:1)Air Infiltration Test,per FBC,TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test,per FBC,TAS 202-94 4) Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6) Forced Entry Test,per FBC 24113.2.1,TAS 202-94 along with marked-up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4957, dated 10/03/06, signed and sealed by Edmundo Largaespada, P.E. (Submitted under previous NOA No.07-0322.06) 2. Test reports on:1)Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings.and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-4958 and FTL-5063, dated 10/03and 11/21/06, both signed and sealed by Edmundo Largaespada,P. E. (Submitted under previous NOA No.07-0322.06) 3. Test reports on:1)Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked--up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-4645, dated 08/11/05, signed and sealed by Edmundo Largaespada, P. E. (Submitted under previous NOA No.07-0322.06) 4. Test reports on:1)Large Missile Impact Test per FBC,TAS 201-94 2) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of an aluminum single hung window, with fin frame, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.'s FTL-4649 and FTL-4723, dated 10/05 and 08/11/05, both signed and sealed by Edmundo Largaespada,P. E. (Submitted under previous NOA No. 05-1018.01) t Jaime D.Gaseo ,P.E. Product Control Section Supervisor NOA No.11-1013.14 Expiration Date: March 26,2016 Approval Date: November 03,2011 E-1