Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2 Florida Departmentof BCIS Home Login I User itegLstration i Not Topics Submit Surcharge Stats A Facts Publications RCStaff BCLS Slte Map Links Search Busines ar-&n PrDduct Approval USER:PuDllcUserProfessi I Regulation Product Aooroval Menu Product or Application Search IInApproved ail • FL# Application Type Code Version Application Status Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 ekoss@cws.cc Authorized Signature Michael LaFevre mlafevre5l@gmall.com Technical Representative Brian Tenace Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext 291 btenace@cws.cc Quality Assurance Representative Cal Ledy Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 22 cledy cwS.cc Category Windo s Subcategory Single Hung Compliance Method Evaluation port from a Florida Registered Architect or a Licensed Florida fessional Engineer valuation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lucas A.Turner the Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 05/17/2016 Validated By Steven M.Urich,PE 8 Validation Checklist-Hardcopy Received Certificate of Independence FL16177 RO COI EvaiReo CWS-812A(SH-8100.Impact.53x63, NoSillAnch).Ddf Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA/101/I.S.2/A440-08 2008 ASTM E1300-04 2004 ASTM E1886-05 2005 ASTM E1996-06 2006 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By httn://www.floridabuilding.org/lor/13r ann dtl.asnx?naram=wGEVXOwtDowf4neAXhlOv... 1/13/2015 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/31/2013 Date Validated 02/18/2013 Date Pending FBC Approval 02/26/2013 Date Approved 04/09/2013 Summary of Products FL# Model,Number or Name Description 16177.1 SH-8100 PVC Single Hung SH-8100 PVC Single Hung Impact Resistant window. Limits of Use Installation Instructions Approved for use in HVHZ:Yes F1,36177 RD II CWS-812A(SH-8100.Impact.53x63. Approved for use outside HVHZ:Yes N_oSillAnch).Ddf Impact Resistant:Yes Verified By: Lucas A.Turner 58201 Design Pressure:+70/-70 Created by Independent Third Party:Yes Other:SH-8100 PVC Impact,Max.FI.size 35,no sill Evaluation Reports anchors required.Safety glazing required on outer lite above FL16177 RO AE DuPont PVB NOA 11-0624 01.0f 30 R.in HVHZ. FL16177 RO AE EvaIReD CWS-812A(SH-8300.Impact. 53x63,NoSillAnch).Ddf FL16177 RO AE Mikron NOA 11-0830 09.odf Created by Independent Third Party:Yes , 1 Next. _ . Contact Us::1940 North Monroe Street,Tallahassee Fl.32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.if you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.Ir you do not wish to supply a personal address,please provide the Department with an email address which can be made avallable to the public To determine It you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: securit nnsTnres 1,tM•//vnamr flnri�r�l�nilrlinn nrrr/nr/r%r ann ffl fhr 1/1 2/7/11 S SINGLE HUNG ELEVATION (LARGE MISSILE IMPACT) PVC IMPACT REQUIREMENT: 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE,CURRENT EDITION. 53 1/6" MAX OVERALL 2.GLAZING OPTIONS:(SEE SHEET 3) FLANGE WIDTH 3.CONFIGURATIONS:"ODC. 517/8"MAX.UNIT WIDTH -IMPACT: PVB SASHAMPACT HOOK 47 11/16"GLASS DLO 4.DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04. -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04. 63" I I 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.SEE SHEETS 6&7 FOR INSTALLATION DETAIL. OVERALL F I I WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR FLANGE HEIGHT CALCULATIONS. R O 2613116 GLASS 6.PRODUCT APPROVED FOR IMPACT RESISTANCE. DLO I I C 7.ALL FRAMES AND VENTS FULLY WELDED.SMALL JOINT SEAM SEALANT 61 3/4" I I USED AT FIXED MEETING RAIL AND JAMB. MAX. UNIT HT. S.SERIES/MODEL DESIGNATION SH-8100. 9.1X OR 2X WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED I I TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.BUCK AND FRAMING IS 30 3/16" I t RESPONSIBILITY OF ARCHITECT OR ENGINEER OF RECORD. . I 26 7/8" SASH GLASS HEIGHT DLO 10.THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING:X=OPERABLE XSASH,0=FIXED SASH 11.SECTION CALLOUTS FROM EQUAL SPLIT ELEVATION APPLY TO ALL I I ELEVATIONS IN A SIMILAR LOCATION. 77E A 6 45 1116" GLASS DLO 48 3/8" MAX SASH WIDTH LUCAS A.TURNER,FL.P.E.,58201 A RECONFIGURED 9/2012 10/18/12 DESIGN PRESSURE RATING IvIluuurepl� ±70 PSF .`N� DRE ��`�PN..... ' P: S 'f' 1VRJD0{VS&DOORS TABLE OF CONTENTS :J�.• �•••'2 No 58201 1900 SW 44TH AVE. GENERAL NOTES&ELEVATIONS.....1 t*: DCALA,FLORIDA 34474 ANCHOR SCHEDULE&NOTES..........2 Lucas Turner fl; ;2 ITLE:GENERAL NOTES&ELEVATIONS-LARGE MISSILE IMPACT GLAZING DETAIL.................................3 2013-01-0313:40-05:00 %V. STATE OF � ER ES: RA NB ATE: SECTION VIEWS..................................4 %0: t EXTRUSIONS&B.O.M.........................5 PROPRIETARYAND CONFIDENTIAL 1/3/2013 .4%%•A, R 10P'.�_��� oDEL:8100 GALE: BAT WG.No6/18/2012 INSTALLATION DETAIL........................6,7 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OFCUSTOM ��S •"••••••• ��� PVC SINGLE HUNG NTS CWS-812 WINDOWSYSTWRITTEN PERMISSION OS INC.ANY CUSTOM WINDOW SYSTEMS,,IR ASA WHOLE INC.IS PROHIBITED.OUT THE ��J�SfOI1f f>t,F'?��, EV.LETTER: A HEET: 1 OF 7 6"MAX. MAX17" --moi A SEE NOTE 2 I MAI 6"MAX. / I I / I I I 0 1 INSTALLATION I 1 1 ANCHORS(TYP) 4- - - - 4" I I I 101/21, MAX O.C. SPACICI NG(TYP.) 4" NOTES: NO ANCHORS REQUIRED IN SILL A 1.INSTALL ONE ANCHOR AT EACH LOCATION AS SHOWN. NO ANCHORS REQUIRED IN SILL 2.SHIM AS REQ'D AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 1/4"FOR MASONRY OR UAL SPLIT) (EQ UT AYO -(EQ WOOD,AND 1/8"FOR METAL. USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. FLANGEANCHOR LAYOUT INSTALLATION THRU FRAME 3.LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 4.3/16"DIA.ELCO ULTRACON MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.EMBEDMENT OF 1 1/4"INTO MASONRY THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY.A MINIMUM EDGE DISTANCE OF 2112",IN ANY DIRECTION,SHALL BE ACHIEVED. 5.#10 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN.EMBEDMENT OF 1 3/8"INTO 2 BY WOOD BUCK A MINIMUM EDGE DISTANCE OF 718"SHALL BE ACHIEVED IN ANY DIRECTION. 6.#10-16 ITW TEKS ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE FULL THREAD ENGAGEMENT THRU METAL WALL THICKNESS. 7.ALL INSTALLATION ANCHORS MUST BE MADE OF OR COATED WITH A CORROSION RESISTANT MATERIAL. DISSIMILAR MATERIALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTIONS. 8.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW. LUCAS A.TURNER,FL.P.E.,58201 �A fREECCONFIGURED 9/2012 10/18/12 {11�11rr LLQ..' 9.INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: ,`011 "'r {r�li1KG[(fvfZ A.WOOD-MINIMUM SPECIFIC GRAVITY OF G=0.55(SOUTHERN PINE OR GREATER) ,,�.�PN°REW TA& C.MASONRY SB.CONCRETE-TRENGTH CONFORMANVE STRENGTH OF 3192 PSI.CE TO ASTM C-90,GRADE N,TYPE 1(OR GREATER). ,�+JVP: gF.,¢2�r H�poWS&Do06S D.ALUMINUM-1/8"THICK MIN.,6063 T5 MIN. ti v. No 58201 ;1�: 900 SW 44TH AVE. E.STEEL-.060"THICK MIN.,33 KSI MIN. _*: .k CALA,FLORIDA 34474 10.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS IN ACCORDANCE WITH THE ;a TITLE: � ANCHOR SCHEDULE 8 NOTES-LARGE MISSILE IMPACT CURRENT VERSION OF THE FOLLOWING REFERENCE DOCUMENTS J 9•: STATE OF �� SERIES: HAWNBY: ATE: FMA/AAMA 100(FIN WINDOWS), RIETARY AND CO 1!3/20 3 ��p•;c p :��� 8100 BAT 06/18/2012 FMA/AAMA 200(FLANGE WINDOWS), THE INFORMATION COMAINEDOIN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM]DENTAL +���5........Rt O'"��`��` MODEL: PVC SINGLE HUNG CALE: NTS WG.NO.:CWS-812 FMAIWDFMA/AAMMA 250 AIWDMA0300(EXTERIOR DOORS). WRITTEN PERMISSION OWINDOW SYSTEMS,INC.F C'CU OM WINDOW SYSNY REPRODUCTION IN TEMS,MS,ART,IINC.IS PROHIBITED.R AS A OHOUT THE EV.LETTER: ASHEET: 20F7 718"OVERALL 7/8"OVERALL 118"ANNEALED OR TEMPERED 1/8"ANNEALED OR TEMPERED 7116"AIRSPACE 7/16"AIRSPACE 5/16"LAMINATED 5/16"LAMINATED 1/8"ANNEALED 1/8"ANNEALED .090"DUPONT PVB INTERLAYER .090"DUPONT PVB INTERLAYER 118"ANNEALED 1/8"ANNEALED 47 SIKAFLEX 552 OR PURFECT GLAZE"H" 47 SIKAFLEX 552 OR PURFECT GLAZE"H" 14 16 112"GLASS BITE 112"GLASS BITE 1 FIXED LITE(EQUAL SPLIT) SASH LITE LUCAS A.TURNER,FL.P.E.,58201 A RECONFIGURED 9/2012 10/18/12 ,,'SAIDIIIIW'1 //nn P1ypREV..T14�� {r4ilCL•LlWfZ ��GENSFGA2 �� WINDOWS&DOORS No 58201 :-P: 1900 SW 44TH AVE. I :* CALA,FLORIDA 34474 ni :It GLAZING GLAZING DEATAIL-LARGE MISSILE IMPACT z - z STATE OF .w� SERIES: HAWNBY: ATE: 3 0�• P:��� 8100 BAT 06/18/2012 THE INFORMATION CONTAINED INPROPMTHI DRAWINGETARY AND I STHE SOLE PROPERTY OF DENTIAL CUSTOM 'I�s•C 13 O R%�•'�j.N, MODEL: PVC SINGLE HUNG CALE: NTS WG.NO.:CWS-812 WINDWRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,,IINC IS PROHIBITED. THE '�ifS11ONA2 E %%� EV.LETTER: A HEFT: 3 OF 7 3 INTERIOR 1 13 32 4 45 45 3 8 38 1 Cr? 14 EXTERIOR 48 35 5 p 54 48 33 17 15 54 19 EXTERIOR INTERIOR 3 6 4 t 14 34 39 7 8 SECTION B-B NOTE:LEFT SIDE SHOWS FIXED LITE CUTAWAY, RIGHT SIDE SHOWS SASH CUTAWAY 9 40 ® 8 62 16 53 48 10 NOTES: ITEMS 20,25,26,36,37,44,51,52, 16 55,56,64,67,68 ARE USED BUT NOT SHOWN 65 FOR CLARITY. 66 62 nn 36 34 U 1/4" //18 (J l�- 30 3 O LUCAS A.TURNER,FL.P.E.,58201 A RECONFIGURED 9/2012 10/18/12 3 4 SECTION A-A ,,` wtitleffi��y�PNORE4II,TGi�,i (EQUAL SPLIT) N7NDOW5&DOORS Z v No 58201 :�1�: 1900 SW 44TH AVE. CALA,FLORIDA 34474 of it ITLE: SECTION VIEWS,EQUAL SPLIT,LARGE MISSILE IMPACT y✓� O�. STATE OF :'� ERIES: DRAWN BY: ATE: L �,p�'0 8100 BAT 06/18/2012 THE INFORMATION CONTAIN D IINPROP�THIS DRAWING IS THE SOLE PROPERTY OF CETARY AND CONFIDENTIAL USTOM i��,i�ss(Q R 10�G� ODEL: PVC SINGLE HUNG CALE: NTS WG NO.CWS-812 WINDOWWRITTEN PERMISSION OF CUSTOM WINDOWSYSTEMS,,IINC.IS PROHIBITED. THE �I�+�ONf f{,�,��� EV.LETTER: A HEET: 4 OF 7 31/8„ FRAME CORNER Item# Part# Description Vendor Material 2 311 s" 1151161,--{ CONSTRUCTION 1 H-6031 Main Fr.,SH,w/Flg.,PVC,Head MSkron Vinyl 1/16" 1116" r-- 41 ` 2 H-6031 Main Fr.,SH,w/Fig.,PVC,Sill Mikron Vinyl 1 8 1116" 3 H-6031 Main Fr.,SH,w/Fig.,PVC,L.Jb. Mii1 5/6" kron Vinyl 4 15/8Fr ` 4 H-6031 Main Fr.,SH,w/Fig.,PVC,R.Jb. NUkron Vinyl 3 10 6 S-1577 Impact Hook Keymark Alum 2 314" 8 H-6027 Sash Meet Rail,PVC Mikron Vinyl p 9 H-1497 Reim.Sash Meet.Rail Keymark Alum CORNER WELD(ALL SIDES) 10 H-6028 Sash Bottom Rail,PVC Mlkron Vinyl PVC SASH MTG.RAIL-6027 PVC SASH BTM.RAIL-6028 12 H-6004 Sash Side/ropBot Rail Mkron Vinyl PVC FRAME FLANGE-6031 13 S-1498 Reinf.S.B.RJS.S.R 1/16" n 14 S-6064 Giz Bd.,718",Fxd., riz Mkron Vinyl �✓ 15 53064 Giz Bd.,718",Fxd.,Vert N6kron Vinyl 1/16" 37 t II){)5�/ 37 16 S-6064 Glz Bd.,718",Sash,Honz Mkron Vinyl 7/8 17 S-6064 Glz Bd.,7/8",Sash,Vert. Mikron Vinyl 1 12 18 S-6013 Scm.Adapt,w/Nib,PVC,Horiz. Miikron Vinyl 3!4" `-J 15/8" .15/16"-i 20 S-6029 Sash Stop/Flier,PVC,Vert Mkron Vinyl 19 S-6014 Scm.Adapt,PVC,Vert Mikron Mnyl 3 21/8 n O PVC SASH STOP-6025 13 23 H-1699 Reinforcement,SBR Keymark Alum 15/16" 1/16" U - I 4'�1 24 P-2190 Balance BSI L H SID TL SCREWED TING 25 P-3059 Sash Cam,PVC BSI Plastic 1 1/2" PVC SASH SIDETHER E RAIL-6004 RAIL 3N6 --II FIXED MEETING RAIL REINF.,S.B.R.-1699 26 P-3046 Take Out Clip BSI SS ALUM 6063-T6 WITH OUTER FRAME 27 P-3783 Lock,Impact,PVC InterlockALU ALUM 6063-IT6 163s REINF.S.B.R./S.S.R.-1498 ALUM 6063-T6 28 P-4069 Keeper,Impact,PVC Intedock Zamac 30 P-3215 WeepCorerw/Flap Gaer Plastic 32 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab 1/2" 1 1 33 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab 5/16„ 2 --{-5/8" 34 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab -1 19 18 15/16" I 9 35 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab 1 118 I 36 P-3429 Wstp.,0.270 x.187 back FinSeal,Gray Ultrafab 'i--- n 1116" 37 P-4638 #8 x2-12 �y PH Mod.Truss,Type A TEK Fastenal Steel 1/16" 1/16" ----X9/16" �_IIL__III 38 P-3768 #8 x0.625 Ph PH SMS Hub City Steel PVC SCREEN SUPPORT-6014 PVC SCREEN CATCH-6013 PVC FIXED RAIL COVER-6063 REINF.SASH MTG.RAIL-1497 39 P4051 W #6 x 1.250 Ph FH TEK,Wht Hub City Steel ALUM 6063-T6 40 P-4264W #8 x3/4 FH PH w/#6 Head,TEK,Wht Hub City Steel 6 44 P-3342 Seam Sealer,SM-5504 Schnee F 1/4" 45 P3752 Cap Plug,1/2"Hole M&M Nylon 0 3116" 47 P-3438 Sikaflex552 or Purfect Glaze"IT' Sika/Henkel O x.070" 48 P-3352 Set Blk.,85 Dur.,118"x5/8"x2"Lg. F.Lowe Rubber 0 51 P-3881 Temporary Lbl.(NFRC/DP) 7/8" 14 15 16 17 3 .1 r-12" 52 P-3613 CWS Lbl.(logo) Pro Label 1— 3 0 53 Sash See Glazing Chart(pg.3) 1N6"---{{{III------ �5"� PVC GLAZING BEAD-6064 54 Fixed See Glazing Chart(pg.3) � 56 P3281 Spacer Duraseal 718 SCREW SUPPORT-3113 62 P3218 Screen Frame,Horiz Allmetal Alum I 63 P-3218 Screen Frame,Vert Alimetai Alum 1+15/16" LUCAS A.TURNER,FL.P.E.,58201 A RECONFIGURED 9/2012 10/18/12 64 P-3321 Screen Frame Comer Key Allmetai Plastic I 65 P-3581 Screen Cloth,18x16 Fiberglass BetterwMP e Fiberglass ACT HOOK-1577 718' +14►tnrirrr 66 P-3228 Screen Spline,.155 Dia.,Blk. Dapa Vinyl ALUM 6063-T6 3 ++++�NpRE4y��110i� 67 P-3029 Screen Pull Tab Summit Alum �++gP�,•••., 68 P-3033 Screen Spring,SS FI.Screen SS �E-.1/16" ��JV�' �' F y� WAIDOWS&DOORS 70 P-3113 Screw Support for PVC T.Plastics Nylon No 58201 1900 SW 44TH AVE. 71 H-1836 Alum.Find Rail Keymark Alum REINFORCEMENT,IMPACT HOOK-1112 :, .G GALA,FLORIDA 34474 ALUM 6063-T6 72 1 S-6063 ICo,%RrFdRail Mkron Vinyl _jr'• ITLE:EXTRUSIONS/B.O.M.-LARGE MISSILE IMPACT 73 S-1112 Reinforcement,Impact Hook Keym ark Alum �'� �9�;• STATE OF :��� ERIES: AWNS ATE: 74 P3541 #8x12",Pan Head,TEK Fastenal Steel IDENTIAL 1/3/2013 '.'C'•c P••=.` 6100 BAT 06/18/2012 THE INFORMATION CONTAINEDIIPRONRETARY AND THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM ��k & ..O•p,0"•G\�v` ODEL: PVC SINGLEHUNG CALE: NTS WG.NO.:CWS-812 NOTE: ITEMS 5,21,22,29,31,41,42,43,49,50,55,57-61 ARE WINDOW SYSTEMS,INC.ANY REPRODUCTION IN PART OR ASA WHOLE WITHOUTTHE ��i S/6ryN E�++` NOT USED ON THIS PRODUCT WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,INC.ISPROHIBITED. ��!►�rr r���iL+� EV.LETTER: ASHEET: 5 OF 7 INTERIOR FINISH 1 114"MIN.EMBEDMENT 13/8"MIN.EMBEDMENT INTERIOR FINISH BY OTHERS [C] [D] INTERIOR FINISH SEALANT BETWEEN BUCK BY OTHERS CONCRETEIMASONRY }•:r •:•••, BY OTHERS AND OPENING BY OTHERS BY OTHERS : .:f.,.••} --..1111 1/4"MAX.SHIM 1/4"MAX.SHIM .5.,. . I �[B] [B] •. D INSTALLATION ANCHOR,3116"DIA. � �d�0 p�p° 2112 MASONRY SCREW WANASHER . �. •• JD MIN.EDGE DIST. (MIN EDGE DIST.) THRU SCREW SUPPORT 0 [ ] 1 -1 (C] CONCRETE/MASONRY �•D• �•D,D D•• • •• 1114" BY OTHERS + D• D D D, D• (MIN EMBEDMENT)[C] p EXTERIOR FINISH ^' • •• A p INSTALLATION ANCHOR, BY OTHERS 1 BY BUCKS 4'• D•p• #10 WOOD ANCHOR BY OTHERS (MIN EDGE DIST.) 4 A WINTEGRATED WASHER PERIMETER SEALANT � [A] [C] .A,:�d• p•;'THRU SCREW SUPPORT BYINSTALLER • 114"MAX SHIM p I SEALANT BEHIND FLANGE r. IND FRAME titd��wy.ti.y!•ti, 2 BY WOOD BUCK BYINSTALLER BY OTHERS 1 BY WOOD BUCK--/ [A] BY OTHERS SEALANT BEHIND FLANGEBYINSTALLER SEALANT BETWEEN [A] EXTERIOR FINISH BUCK AND OPENING WINDOW FRAME BY OTHERS PERIMETER SEALANT BY OTHERS HEAD INSTALLATION ANCHOR,3116"DIA. BYINSTALLER BYINSTALLER MASONRY SCREW wNVASHER HORIZONTAL SECTION BYOERIOR OTHERS FINISH THRU SCREW SUPPORT FRAME(MASONRY) [C] RC1 HORIZONTAL SECTION FRAME(WOOF Y WINDOW FRAME O CONTINUOUS DOUBLE 3116'•BEADS OF TREMGLAZE U1600 SEALANT SILL OR EQUIVALENT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND BUCK BY INSTALLER. SEALANT BEHIND FLANGE BYINSTALLER WINDOW FRAME 1/4"MAX.SHIM SILL PERIMETER SEALANT (BI BYINSTALLER REFERENCE NOTES: EXTERIOR FINISH Q D - °. °- °. ° - ° D [A]SEE NOTE 9,BHT 1 BY OTHERS o D• o D.o [C]SEE NOTE[B]SEE NOTE 2&4,BHT 2 SEALANT BEHIND FLANGE TREMGLAZE U1600 SEALANT AROUND - ° D °CONTINUOUS DOUBLE 3/16"BEADS OF - o- °D ° °. °D °- °D [D]SEE NOTE 5,SHT 2 BYINSTALLER -- PERIMETER AT ALL INDICATED POINTS D• > °'t,°D. ° D D D D D D D D D BETWEEN FRAME AND BUCK BY INSTALLER. °D ° D• D °• °• °- ° ° - BYRSEALANT D p °p D°D• o D. o D o NSTALLER114" D. o � MAX SHIM EXTERIOR FINISH B BY OTHERS CONCRETE/MASONRY ••D• BY OTHERS LUCAS A.TURNER,FL P.E.,58201 A RECONFIGURED 9/2012 10/18/12 • •• ~• o.=. SILL STOOL D: ••P•.D• •D. D BY OTHERS 11�IAORElie�/ D• D� o�D•D. •D• D. .D•D. D• •D•D••c �p�ALTERNATE PRECAST SILL DETAIL �%% p.N.REN'T��4 D; D, D•D, • •••D • D D, • • D D. • USE SOLID WOOD FRAME MASONRY , •••CEN••'•G^^���� ••D•,•• •D,D•.D• D •• D,•D• •• D••p ( ) JP,• \ S ;r�' WINDOWS&DOORS SUPPORT TO MAKE �7; \• F 'Z •D. D. D' • D••.D • D• •D • •D• SILL LEVEL BY OTHERS •D- •• p•• D.�• •D•D:•D. •=•D��o•�o; No 58201 1900 SW 44TH AVE. • :*: * ;* CALA,FLORIDA 34474 CONCRETE/MASONRY :n:. INSTALLATION ITLE: BY OTHERS y Z 9 STATE OF .w: i Q:• A/ ERIES: RA N B ' ATE: HIGH STRENGTH 1/3/2013 i n�A' P••�•�� 8100 BAT 06/18/2012 STRUCTURALTHETION PROPRIETARYAND CONFIDENTIAL '• 0 R 10,.E G���� MODEL: GALE: WG.NO.: GROUT BY OTHERS �A1 VERTICAL SECTION WINDOW SINFORYSTEMSCNC.ANY REPRODUCTION N PART OR AS NED IN THIS DRAWING IS THE SOLEPROPERTY WITHOUT THE e'��ss/ONA%—S,. � PVC SINGLE HUNG EV.LETTER:TS HEET: CWS-812 ON (MASONRY) WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS,INC.IS PROHIBITED. 11111111111 A 6 OF 7 1/8"MAX.SHIM INSTALLATION ANCHOR, [D] #10 SCREW PERIMETER SEALANT BYINSTALLER [-118"MAX SHIM Q SEALANT BEHIND FLANGE BYINSTALLER WINDOW FRAME WINDOW FRAME HEAD INSTALLATION ANCHOR, BYRNSTALLER��� JAMB #10 SCREW [C] SEALANT BEHIND FLANGE BYINSTALLER S HORIZONTAL SECTION WINDOW FRAME SILL n REFERENCE NOTES: Ll]I CONTINUOUS DOUBLE 3116"BEADS OF TREMGLAZE U1600 SEALANT OR EQUIVALENT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN [A]SEE NOTE 9,BHT 1 FRAME AND BUCK BY INSTALLER. [B]SEE NOTE 2&3,SHT 2 [C]SEE NOTE 6,SHT 2 [D]SEE NOTE 9,SHT 2 SEALANT BEHIND FLANGE 1/8"MAX SHIM BYINSTALLER PERIMETER SEALANT BYINSTALLER [D] LUCAS A.TURNER,FL.P.E.,56201 q RECONFIGURED 9/2012 10/18/12 lIkllllllllllll'r ��P14ORE.. ,�� , VERTICAL SECTION .,JGP0%''\O E N 5..��Q,yc``�' DQws&Do°lts ti. No 58201 1900 SW 44TH AVE. * ;*Z DCALA,FLORIDA 34474 ITLE: ION DETAIL TH FRAME-LARGE MISSILE IMPACT �9�• STATE OF .41 ERtES: HAWN 81600 /18/2012 BY:BAT ATE: THE INFORMATION CONTAINED IN THIS RAWING IS THE PROPRIETARY AND SOLE PROPERTY OF CUSTOM �013 ��10;6S�**. R t P p�2� MODEL:PVC SINGLE HUNGALE: NTS v"G.NO.:CWS-812 WINDOW PERMISSIONSYSTEMS. .ANY REPRODUCTION WI DOOM IN PART OR IS WHOLE WIT OUT THE ,,'�118111111210%1 �`` LETTER: qSHEET: 70F7