Loading...
HomeMy WebLinkAboutWind Load Calculation Planning&Development Services Department Building&Code Regulations Division • 2300 Virginia Avenue, Fort Pierce, FL 34982—(772)462-1553 Certification for Design Load Compliance Project Name: 00 V_ 12� FLA t=iff MCaa r Project Address: 52— ,,J Gti.e S if Q,f1l 6l1� 1=- L Permit#: Occupancy Type: Type: C-,9 NC'R'�Y'E/,71 A4:0M/Zy INSTRUCTIONS FOR USE: / This certification must be completed,signed,and sealed by the design professional of record. Submit(2)copies for residential,(3)copies for commercial with:all perrnit applications involving the following. 0 New Residences(single or-multi-family) o Residential Addition c a Any accessory structure requiring a building permit CcLoc DrS \ _?p o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) OVj6 S 1. DESIGN CODE: Florida 41"'- Code 2010 Edition with 20J�_Supplements using ASCE 0 2. Structure Designed as(check one): Enclosed Partially Enclosed Open 3. Risk Category: _I A-,[1 III IV Exposure Category: B C 4. Design Wind Velocity 160 pt tmph ASD LRFD End Zone Width: /S ft 5. Mean Roof Height Jib I ft Roof Pitch: .i :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: 4"'_ Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcdny: PSF Dock:. . PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Yes Not Applicable Explain Why Not: CcfB D.V' rG rrh h 0. Design Soil Bearing Pressure-.. PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of.my knowledge and belief,the attached plans &specifications have been designed to comply wit 0,1 structural portions of the building codes currently adopted and enforced by St. Lucie Cou`o-1 IIs8RE],�'4t;u'tura)elements depicted on these plans provide adequate resistance to the design ,� .-9 for �� fJ 1-i H Qm d3J2ti'�►?><�-1 l3 Ba G}1 Pf. S9° '7 0 No 5 0770 Print Name Cert#&Co.Cert Auth. -o-�'f STATE OF= Breitenbach Engineering signs •Da' � X31••®� 4553 SE Pilot Way �1� •'• Compan Stuart, Florida 34997 s/®NAL ,, Revised 07/2'�'/20114���'�'�