Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspjc?param=wGEVXQ... IM r Fonda DepagWntd BCIS Home Log In User Registration j HotTopics Submit Surcharge { Stats.&Facts I Publications i FBC Staff j BCIS Sae Map Links j search Uusil les t T' Product Approval Professi a USER:Public User Vill Regulation Product Approval Menu>Product or Avvdon a rch>Avofication Ust>AppgCdtbn DetaB FL# FLi�956-R8 Application Type Revision Code Version 2010 Application Status Approved PP PP *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerr! Eden kerri—eden@tamko.com Technical Representative Kerr! Eden Address/Phone/Ercall PO Box 1404. Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative. . Address/Phone/Emal l Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert].M.Nleminen,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year . ASTM D3161 2006 ASTM D3462 2007 ASTM D7158 2007 Equivalence of Product Standards Certified By Product Approval Method' Method 1 Option A 1 of 4 11/7/2013 8:49 AM Florida Building Code Online http://www.floridabuildingorg/pr/Pr_app_dtl.aspx?param—w GEVXQ... Date Submitted 09/27/2012 Date Validated 10/15/2012 Date Pending FBC Approval Date Approved 10/16/2012 Summary of Products M# Model,Number or Name Description 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate 1 Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or.greater.Nails must be used FL1956 R8 II glass seal elite apo Inst april 10.pdf as the method of attachment. FL1956 R8 II glass seal elite app inst f april 10. _df FL1956 R8 II TAMKO Glass-Seal Elite Glass-Seal(Frederick Joplin Tuscaloosa).pdf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/16/2015 Other:Asphalt shingles shall be used only on. Installation Instructions roof slopes of 2:12 or greater.Nails must be used FL1956 R8 II glass seal elite app inst april 10.pdf as the method of attachment. FL1956 R8 II TAMKO Glass-Seal Elite Glass-Seal(Frederick Joplin Tuscaloosa).odf Verified By: Robert Nieminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956_2012.pdf Approved for use outside HVHZ:Yes FL1956 R8_C CAC UL certification 10-11-12.pcif Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nails must be used FL1956 R8 II heritage app Inst-sept 12.pdf as the method of attachment. FL1956 R8 II heritage app inst frederick.pdf Verified By: Robert J.M.Nieminen FL 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC OL certification 10-11-12.pdf Impact Resistant:.N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater. Nails must be used FL1956 R8 II heritage 30 app Inst'april 10.pdf as the method of attachment. FL1956 R8 II heritage 30 app Inst f april 10.pdf i Verified By: Robert Nieminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.5 Heritage 50 A dimensional asphalt shingle. t Limits of Use Certification Agency Certificate Approved for use In HVHZ:No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10,11-12.odf 2 of 4 11/7/2013 8:49 AM Florida Building Code Online' http://www.floridabuilding.org/pr/pr app_dtl.aspx?parani—wGEVXQ... Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or.greater.Nails must be used FL1956 R8 II heritage 50 apo Inst april 10.pdf as the method of attachment. FL1956 R8 II.heritage 50 app Inst f_april 10.1)df Verified By: Robert Nleminen PE 59166 Created by Independent Third Party: No . Evaluation Reports Created by Independent Third Party: 1956.6 Heritage Premium A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.odf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nails must be used. FL1956 R8 II heritage prem app inst.pdf as the method of attachment. FL1956 R8 II herltage prem apo Inst frederick odf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.7 Heritage Woodgate A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No 'FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12 pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nalls.must be used FL1956 R8 II Woodgate app inst D Oct 11.pdf as the method of attachment. FL1956 R8 II Woodgate app Inst F Oct 11.pdf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.8 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes FL1956 R8 C CAC UL certification 10-11-12.pdf Impact Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure:N/A 10/10/2015 Other:Asphalt shingles shall be used only on Installation Instructions roof slopes of 2:12 or greater.Nails must be used FL1956 118 II heritage A app Inst d april 10.pdf as the method of attachment. FL1956 R8 II heritage A app Inst f april 10.ndf. Verified By: Robert Nleminen PE 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.9 Hip and Ridge Shingles Hip and ridge shingles Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R8 C CAC Tamko Sery Conf FL 1956 2012.pdf Approved for use outside HVHZ:Yes . FL1956 R8 C CAC UL certification 10-11-12.pdf Impact.Resistant:N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 10/10/2015 Other:Hip and Ridge shingles shall be used only Installation Instructions on roof slopes of 2:12 or greater.Nails must be FL1956 R8 11 12 25 x 12 Hip Ridge_Application Instructlons.pdf used as the method of attachment. FL1956 R8 II 12 x 12 Hip Ridge Aoolication Instructions.pdf FL1956 R8 II 12-1-4x12 HiDRidge Sealant Dab Illustrations.odf FL1956 R8 II 12x12 HlpRidge Sealant Dab Illustrations.pdf Verified By: Robert Nleminen 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: Back _Next 3 of 4 11/7/2013 8:49 AM ® Application Instructions for TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT.It is not necessary to remove the plastic strip from the back of the shingles. 1.ROOF DECK &FASTENERS These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these and retaining fasteners,and to inclines of not less than 2 in.per foot. shingles after application when proper sealing of the shingles For roofs having pitches 2 in.per foot to less than 4 in.per foot,refer does not occur. This can especially be a problem if the shingles to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not be applied properly.TAMKO assumes no responsibility for leaks or receive direct sunlight.These conditions may impede the sealing defects resulting from improper application, or failure to properly of the adhesive strips on the shingles. The inability to seal down prepare the surface to be roofed over. may be compounded by prolonged cold weather conditions and/ NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is dry and free from warped surfaces. It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized drip edges be installed at eaves and rakes. dabs of TAM-PROO Premium SBS Adhesive or TAMKO Tam-Seal Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm) PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the Engineered Wood Association.Plywood shall be a minimum of 3/8 shingle. Press shingle firmly into the adhesive.For maximum wind in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or SHEATHING BOARDS: Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive. Caution: Apply ONLY a thin uniform and-groove boards and not over 6 in.nominal width. Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in spaced and nailed. certain underlayments resulting in the asphalt flowing,dripping and staining.Shingles must also be fastened according to the fastening 2.VENTILATION instructions described below. Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the These conditions can lead to: diagram and described below,this will result in the termination of TAMKO's liabilities under the limited warranty.TAMKO will not be 1.Vapor Condensation responsible for damage to shingles caused by winds in excess of 2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty. See limited 3.Rotting of wood members. warranty for details. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from 4.Premature failure of roof. the bottom edge of the shingle, penetrating through the common To insure adequate ventilation and circulation of air, place louvers bond,and located horizontally as follows: of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in. ridge and soffit vents. FHA minimum property standards require per foot to 21 in. per foot.)One fastener 1 in.back from each end one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of 4 of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below). vapor barrier is installed on the warm side of the ceiling or if at least one half of the ventilation is provided nearthe ridge.If the ventilation STANDARD FASTENING PATTERN openings are screened,the total area should be doubled. FASTENERS NAIL ZONE COMMON BOND IT IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION. 6-1/8' FEXPOIURE5-5/8" 1 12-1/2"—►-12-3/8"—+— 12-1/2"--► h--1" (Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1 ® (CONTINUED from page 1) TAMKO HERITAGE® 30 MIXING PRODUCTS LAMINATED ASPHA6T SHINGLES Dallas, TX • Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for greater than 21 in.per foot.)One fastener 1 in.back from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The and one fastener 8-1/2 in.back from each end and one fastener 16 crown of the staple must be parallel to the length of the shingle. in. back from each end for a total of 6 fasteners per shingle.(See The staple crown should be driven flush with the shingle surface. Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered MANSARD AND HIGH WIND FASTENING PATTERN improperly applied. FASTENERS NAIL ZONE Properly Driven Improperly Driven COMMON Sha" underdriven overdriven crooked BOND ISN Asphalt Shingles 5- [EXPOSURE 5-5/8" .E Decking +� Irz-+rz"►h-�-+2"�'7-arae-�-+rz"�.-�-1rz"°I h--+ ��<min. 3) High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL requirements)One fastener 1 in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE. 8-1/2 in.back from each end and one fastener 16 in.back from each 4.UNDERI6ATMENT end fora total of six(6)fasteners per shingle.In addition to this shingle fastening pattern requirement for High Wind Application, TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated also requires the use of the following TAMKO products: TAMKO felt must be applied over the entire deck before the installation of felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited coatings products where required;TAMKO ventilation where required, warranty.Apply the felt when the deck is dry. On roof decks 4 in. TAMKO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends to the underlayment and each other in a 4 in.(102 mm)width of TAM- join, lap the felt 4 in. If left exposed, the underlayment felt may PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together. is offered on new construction or complete tear-off applications only. Products which are acceptable for use as underlayment are: It is not offered for recover applications. If High Wind Application requirements are not followed,the High Wind Application Warranty — TAMKO No. 15 Asphalt Saturated Organic Felt MPH, as stated on Table I in the Limited Warranty, reverts to the — A non-perforated asphalt saturated organic felt which meets Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I High Wind Fastening Pattern illustrated above.) — Any TAMKO non-perforated asphalt saturated organic felt — TAMKO TW Metal and Tile Underlayment,TW Underlayment NAILS:TAMKO recommends the use of nails asthe preferred method and Moisture Guard Plus® (additional ventilation may be of application. Standard type roofing nails should be used. Nail required.Contact TAMKO's Technical Services Department shanks should be made of minimum 12 gauge wire,and a minimum for more information.) head diameter of 3/8 in.Nails should be long enough to penetrate 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem, TAMKO's plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent Properly Driven Improperly Driven water damage. Contact TAMKO's Technical Services Department 0=3/8•min diameter underdriven overdriven crooked for more information. Asphalt _ } Shingles TAMKO does not recommend the use of any substitute products Decking as shingle underlayment. e3 iii 1 1/4°nominal straight,good penetration, inadequate too deep,cuts Inadequate S.APP6ICATION INSTRUCTIONS and(lush with shingle surface penetration Into shingle anchorago STARTER COURSE:A starter course may consist of TAMKO Shingle Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral STAPLES: If staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved dimensional requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in.above the eaves 16 gauge galvanized wire.Crown width must be at least 15/16 in. edge.The starter course should overhang both the eaves and rake (staple crown width is measured outside the legs).Leg length should edges 1/4 in.to 3/8 in. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2 ® (CONTINUED from page 2) TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHA6T SHINGLES Dallas, TX • Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO SHINGLE APPLICATION:Startthe first course with a full size shingle 6.6OW SLOPE APPI61CATION and overhang the rake edge 1/4 in.Cut 10-3/8 in.from a full shingle On pitches 2 in.perfoot to 4 in.per foot cover the deck with two layers to form a shingle 29 in.long.Use this to start the second course(see of asphalt saturated felt.Begin by applying the felt in a 19 in.wide strip diagram below).Cut a 23 in.long shingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place the remaining 16-3/8 in.piece of shingle to start the fourth course and a full 36 in.wide sheet over the 19 in.wide starter piece,completely use the remaining 10-3/8 in.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the up the rake in as many rows as necessary using the same formula preceding course by 19 in.If winter temperatures average 25oF or less, as outlined above.The butt of the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO or TAMKO the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in. exposure(see shingle application drawing illustrated on this panel). inside the interior wall line of the building.As an alternative,TAMKO's When you make your final cut at the roof's edge,flip any pieces that Moisture Guard Plus®self-adhering waterproofing underlayment may are 8 in.or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts. in anywhere without creating zippers or color variations. NOTE:Do not align joints of shingle courses when working in cut 7•MANSARD ROOF OR STEEP SLOPE ROOF pieces.Joints should be no closer than 4 in.from one another. If the slope exceeds 21 in.per foot(601,each shingle must be sealed with TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately upon installation.Spots of cement must be equivalent in size to a$.25 piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners 10-3/8" per shingle.See Section 3 for the Mansard Fastening Pattern. _� 8.RE-ROOFING repeat 10 /8 ".NRQQ'�'courses 16.3/8^ J�PBefore re-roofing,be certain to inspect the roof decks.All plywood 23" shall meet the requirements listed in Section 1. 29,,, Nail down or remove curled or broken shingles from the existing 16-3/8" 23„ roof.Replace all missing shingles with new ones to provide a smooth rake Fun base. Shingles that are buckled usually indicate warped decking 10-3/e" or protruding nails. Hammer down all protruding nails or remove them and refasten in a new location. Remove all drip edge metal 5th course 23" 16-3/8° and replace with new. 4th course 16.918 _ If re-roofing over an existing roof where new flashing is required s d course 23"• i to protect against ice dams(freeze/thaw cycle of water and/or the 2nd course _x.29 backup of water in frozen or clogged gutters),remove the old roofing to a point at least 24 in. beyond the interior wall line and apply 1st course Full 10-3/6" TAMKO's Moisture Guard Plus®waterproofing underlayment.Contact saver. TAMKO's Technical Services Department for more information. Measurements will vary when nesting over an existing 5 in.exposure single roof:Call TAMKO Technical Services for further information. Cut your first Course shingle to make 29'and a 10 3/e' length.Cut a second shingle to make a 23'and The nesting procedure described below is the preferred method for a 15319°length. =— reroofing over existing metric size shingles with a 5-5/8 in.exposure. 29° 103 ^ See description below: 11838. Starter Course:Remove the tabs and an additional portion from the head of a full size shingle so that its height is equal to the exposure of the existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves). Cut approximately 6 in.from the rake end and apply the remaining portion at the eaves.Continue the starter strip by applying full length shingle strips cut to height as above,evenly along the existing roof at the eaves.The existing roof should overhang the eaves far 2Thantoyyourtionwith afull 1wan 1031e. g enough to carry water off into the gutter.If this is not the case Then lay your 29'.23'.16 3/e"and 10 3/e°len ths, r As sea.three shingles with two cuts makeke fi,.courses. cut and apply the starter strip so that it will provide sufficient five overhang for proper drainage. 3Con tinuewoemof's edgway lip ossany piees f.WhenMat are you make your First Course:Remove an amount from the butt edge of a full-size .foal cut at the mo Ps edge,lac any pieces mal are e°or longer back onto thereof.These places can be worked In anywhere without shingle so that the remaining portion of the shingle fits between the rearing zippers or color variations. NOTE:Do not align joints of shingle courses when working In butts of the existing third course.This course must also be applied cut pieces.Joints should be no closer than 4'from one onomer. evenly along the eaves edge of the new starter strip. (Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast.District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.eom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 ® (CONTINUED from page 3) TAMKO HERITAGE® 30 BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO Second and Succeeding Courses: Remove 10-3/8 in. from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE rake end of the first shingle in the second course, and continue CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT. with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old Valley centerline shingle in the course above.This method should create an exposure Minimum 3.Moist sheet 9 P of Nail Fast.Moisture of 5-5/8 in.after the first course.When beginning the succeeding Guard Plus or 50 lb. Extra nail in or heavier roll roofing end of shingle courses continue to follow the Heritage application instructions. Extend end shingle 12'-1 a'beyond (See section 5). / valley centerline Existing shingles Undedayment No fasteners within -�5 5/8" / 6'of centedine \ 131/4 . Drip edge ^ Place tip of shingle on the edge of the vertical shingle.2 inches back Drip edge Irom valley centedine and covering New shingles the vertical shingle. 55/8° \,v// 5 5/8"exposure 10.HIP AND RIDGE FASTENING DETAIL exposure j / Apply the shingles with a 5 in. exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the 9.VALLEY APPLICATION prevailing winds.Secure each shingle with one fastener on each side, 5-1/2 in.back from the exposed end and 1 in.up from the edge. Over the shingle underlayment,center a minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hip & Ride shingle of TAMKO Nail-Fast®,Moisture Guard Plus®or a minimum 50 Ib.roll products.Where matching colors are available, it is acceptable to roofing in the valley.Nail the felt only where necessary to hold it in use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. place and then only nail the outside edges. IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should be 1/4 in.longer than the one used for shingles PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE After valley flashing is in place: BENDING SHINGLE IN COLD WEATHER. • Apply the first course of shingles along the eaves of one of the Direction prevailing wind intersecting roof planes and across the valley. Start 5"exposure Note:For proper flow of water over the trimmed shingle,always here— start applying the shingles on the roof plane that has the lower �5�-- � slope or less height. � Fastener P 9 �� `5-1/2.. • Extend the end shingle at least 12 in.onto the adjoining roof. MFnl\ here 9 Apply succeeding courses in the same manner,extending them 5"exposure across the valley and onto the adjoining roof. • Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES Note:No fastener should bewithin 6 in.of the valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING and two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE crossing the valley. MANUFACTURER'S INSTRUCTIONS. • To the adjoining roof plane,apply one row of shingles vertically facing the valley and 2 in.back from the valley centerline. Note: For a neater installation, snap a chalkline over the TAMKOO,Moisture Guard Plus®,Nail Fast®,TAM-PRO®and Heritage®are registered P trademarks of TAMKO Building Products.Inc. shingles for guidance. Information included in these application instructions was current at time of printing.To • To complete the valley, apply shingles on the adjoining roof obtain a copy of the most current version of these application Instructions,visit us online plane by positioning the tip of the first shingle of each row at at tamko.com or call us at 800-641-4691. the 2 in.point from the centerline where the edge of the vertical shingle has been applied,covering the vertical shingle. Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 11109 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4 Florida Building Code Online Page 1 of 4 rid Aodda Departmentof BCIS Home I Log In User Registration Hot Topics Submit Surcharge (Stats&Facts Publications FBC Staff BCIS Site Map I Links SearchIN 1 Businest Product u ser Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL12328-R4 Application Type Revision Code Version 2010 Application Status Approved Comments Archived 0 Product Manufacturer TAMKO Building Products Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerri Eden kerri—eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who Zachary R. Priest developed the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/26/2016 Validated By Locke Bowden E?] Validation Checklist-Hardcopy Received Certificate of Independence FL12328 R4 COI TBP14001 2010 FPA TAMKO Underlavments FINAL.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2001 ASTM D226 2006 ASTM D4869 2005 ASTM D6380 2003 https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuarj gOlAram... 4/10/2015 Florida Building Code Online Page 2 of 4 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/23/2014 Date Validated 10/23/2014 Date Pending FBC Approval 10/26/2014 Date Approved 12/15/2014 Summary of Products FL# IlModel,Number or Name IlDescription 12328.1 ASTM Slate Surfaced Roll Roofing IlRoll roofing surfaced with mineral granules Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underlayments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf Created by Independent Third Party:Yes 12328.2 ASTM Tile Underlayment Coated organic underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FINAL. df Impact Resistant:N/A Verified By: Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf 11 Created by Independent Third Party:Yes 12328.3 Master Smooth Asphalt saturated organic underlayment. Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FINAL. df Impact Resistant: N/A Verified By: Zachary R.Priest 74021 Design Pressure:N/A Created-by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf Created by Independent Third Party:Yes 12328.4 Moisture Guard Plus 11A self-adhering modified bitumen underlayment. Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf 11 Created by Independent Third Party:Yes 12328.5 No. 15 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underla mens FINAL. df Created by Independent Third Party:Yes https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuarj gOlAram... 4/10/2015 Florida Building Code Online Page 3 of 4 12328.6 JjNo. 15 ASTM D4869 JjAsphait saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes f Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.odf Created by Independent Third Party:Yes 12328.7 No. 15 UL lAsphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Ude la ments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf Created by Independent Third Party:Yes 12328.8 No.30 ASTM Asphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underlayments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.odf 11 Created by Independent Third Party:Yes 12328.9 No.30 ASTM D4869 IjAsphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.Ddf Created by Independent Third Party:Yes 12328.10 No.30 UL JlAsphalt saturated organic felt Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underlayments FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.odf Created by Independent Third Party:Yes 12328.11 TW Metal and Tile Underlayment self-adhering modified bitumen underla ment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla ments FIN L. d Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL,Ddf 11 Created by Independent Third Party:Yes 12328.12 TW Underlayment self-adhering modified bitumen underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL12328 R4 II TBP14001 2010 FPA TAMKO Approved for use outside HVHZ:Yes Underla mens FINAL. df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL12328 R4 AE TBP14001 2010 FPA TAMKO Underlavments FINAL.odf Created by Independent Third Party:Yes https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuarj gOlAram... 4/10/2015 Florida Building Code Online Page 4 of 4 Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Stat m nt::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. *Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: ® eChMEE .'cTf N SCCIll'1LY.lr�TKFW' https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtF2Aezuarj gOlAram... 4/10/2015 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 21, 2014 P.O. Box 1404 Joplin, MO 64802 (417)624-6644 htto://www.tamko.com Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.2.4, 1507.2.9.2, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3, 1507.9.5 Properties: Physical properties REFERENCES En& Report No. Standard Year PRI Construction Materials Technologies(TST6049) TAP-191-02-01 REV ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) TAP-192-02-01 ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) TAP-193-02-01 ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) TAP-214-02-01 ASTM D 4869 2005e1 PRI Construction Materials Technologies(TST6049) TAP-215-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-216-02-03 ASTM D 6380 2003 PRI Construction Materials Technologies(TST6049) TAP-217-02-01 REV ASTM D 6380 2003 PRI Construction Materials Technologies(TST6049) TAP-218-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-219-02-01 ASTM D 226 2006 PRI Construction Materials Technologies(TST6049) TAP-220-02-01 ASTM D 6380 2003 PRI Construction Materials Technologies(TST6049) TAP-222-02-01 ASTM D 4869 2005e1 UL LLC(TST9628) 13CA12269 ASTM D 226 2009' 'The 2009 publication year has been found equivalent to the 2006 publication year required by the 2010 FBC. PRODUCT DESCRIPTION AND APPLICATION TAMKO®ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. Min.slope: 2:12 Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"staggered end laps and in accordance with FRSA/TRI 07230 for tile applications. Allowable roof coverings: Attachment of asphalt shingle valleys and clay and concrete tile shall be permitted in accordance with the FBC. TBP14001 FL12328-R4 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 9N-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO®ASTM Tile ASTM D 6380, Class M,Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"staggered end laps and in accordance with FRSA/TRI 07230 for tile applications. Allowable roof coverings: Attachment of clay and concrete tile shall be permitted in accordance with the FBC. TAMKO®Master ASTM D 6380, Class S,Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Application: The underlayment shall be installed along the valley in accordance with FBC requirements. Allowable roof coverings: Attachment of asphalt shingle valleys shall be permitted in accordance with the FBC. TAMKO®Moisture Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard Plus® with a mineral surfacing and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 3-1/2" side laps and minimum 6"staggered end laps. Min. application temperature: 40°F. Allowable roof coverings: Attachment of asphalt shingles and mechanically fastened concrete and clay tile roofing shall be permitted in accordance with the FBC. TAMKO®No.15 ASTM ASTM D 4869, Type I, underlayment constructed from a non-perforated organic felt that D 4869 Asphalt is saturated with asphalt. Saturated Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No. 15 ASTM ASTM D 226,Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TBP14001 FL12328-R4 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. GREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO®No.16 UL ASTM D 226, Type I underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.30 ASTM ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete tile, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.30 ASTM ASTM D 4869, Type I underlayment constructed from a non-perforated organic felt that D 4869 Asphalt is saturated with asphalt. Saturated Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt, metal, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®No.30 UL ASTM D 226,Type 11 underlayment constructed from a non-perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt Application: The underlayment shall be installed with minimum 2" side laps and minimum 4"end laps. Allowable roof coverings: Attachment of asphalt shingles, metal roofing, clay and concrete tile, slate shingles, wood shingles, wood shakes, and roll roofing shall be permitted in accordance with the FBC. TAMKO®TW Metal and Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Tile Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered end laps. Min.application temperature: 40°F Allowable roof coverings: Attachment of asphalt shingles, metal roofing, and mechanically fastened clay and concrete tiles shall be permitted in accordance with the FBC. TBP14001 FL12328-R4 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC TAMKO®TW Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. Application: The underlayment shall be attached by adhering directly to the roof deck with minimum 4" side laps and minimum 6"staggered end laps. Min. application temperature: 40'F Allowable roof coverings: Attachment of asphalt shingles and metal roofing shall be permitted in accordance with the FBC. LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Minimum application temperature shall be 50°F unless otherwise noted. Contact the manufacturer when installing at temperatures below the minimum application temperature. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 7) The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be installed in accordance with FBC requirements. 8) Unless otherwise stated,the minimum roof slope shall be in accordance with FBC requirements. 9) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 10) The underlayment may be used as described in other current FBC product approval documents. 11) The underlayment shall not be installed over existing roof coverings. 12) Contact the manufacturer regarding specific exposure limits for each underlayment. 13) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. TBP14001 FI-12328-R4 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TAMKO BUILDING PRODCUTS,INC. TAMKO Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. R.0. �•tiQ.•,.�'�G E NSF • �,>•�� No 74021 2014.10.21 * _ 20:17:38 -33:. STATE OF :��/� -04'00' �����•'c� O R O P'•N :�� Zachary R. Priest, P.E. � �%,` Organization No.Floridalon ANE9641 21 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT TBP14001 FL12328-R4 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Florida Building Code Online http://www.floridabuildiiag.orgfpr/pr_app_dtl.aspx?parani—wGEVXQ... e o 0 e • 8 A . . Q r 0 .BCIS Home 4 Ing In User Registration Hot Topics ' SubmltSurcharge Stats&Facts { Publicati.. 1 FBC Staff t SCIS Site Map Unks Search F0(Id2()2p3ftIT1 d Busines ' . ProfessigFa! 9 product Approval USER:Public User 1R�eeggurJllaaltiio�n11�� - L7LSiY1`i'YIVYIIIitili Li{'JY7GYftY Product Aooroval Menu>Product or Aootp[bn Search>ApplIcatlon Ust>Application Detail FL# FL12570-R2 Application Type Revision Code version 2010. Application Status Approved *Approved by DCA.Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Arch lved Product Manufacturer Sun Tek Mfg Address/Phone/Email 10303 General Dr Orlando,FL 32824 (407)859-2117 jfeudnerL@sun-tek.com Authorized Signature James Feudner engineering@sun-tek.com Technical Representative James Feudner Address/Phone/Email 10303 General Dr Orlando,FL 32824 engineering@sun-tek.com Quality Assurance Representative James Feudner Address/Phone/Email 10303 General Dr Orlando, FL 32824 (407)859-2117 Ext 111 englneering@sun-tek.com Category Sky Lights Subcategory Skylight Compliance Method Certiflcation Mark or Listing Certification Agency National Accreditation&Management Institute, Validated By National Accreditation&Management Institute, Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 . Equivalence of Product Standards Certified By 1 of 3 5/29/2013 11:24 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_ d.aspx?param--wGFVXQ... Product Approval Method Method 1 Option A Date Submitted 03/14/2012 Date Validated 08/17/2012 Date Pending FBC Approval Date Approved 08/20/2012 Summa of Products FL# Model;Number or Name Description.. 12570.1 CMA-D curb mounted polycarbonate bubble with welded aluminum ring Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC CMADNI011086.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2014 Design Pressure: +60/-60 Installation Instructions Other: FL12570 R2 II CMADInstallsBCIS.pdf Verified By:James D.Wells.Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports FL12570 R2 AE,5 14 12 CMAD Approved Evaluation Report.0 Created by Independent Third Party:Yes 1.2570.2 HSF. Self flashing aluminum frame with polycarbonate bubble. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC HSFNI011087(21.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2014 Design Pressure:+60/-60. Installation Instructions Other:max size r.o.46.5 x 46.5 FL12570 R2 II HSFlnstallsBCIS.Ddf Verified By:James D.Wells Jr.P.E. P.E.#53616 Created by Independent Third Party:Yes EvaluationReports FL12570 R2 AE 5 21 12 HSF Approved Prod Eval Report.ndf Created by Independent Third Party:Yes 12570.3 ICMG Curb mounted glass impact rated skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC ICMGNI006223-R4(2).Pdf' Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2014 Design Pressure: +60/-60 Installation Instructions Other:max size r:o.46.5 x 46.5 FL12570 R2 II ICMGinstallsBCIS.pdf Verified By:James D,wells Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports FL12570 R2 AE 7 16 12 ICMG Approved Evaluation reoort.pdf Created by Independent Third Party:Yes 12570.4 I$FG Self flashing Impact rated glass skylight Limits of Use Certification Agency Certificate Approved.for use in HVHZ:Yes FL12570 R2 C CAC ISFGNI006214-R4.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2014 Design Pressure: +6.0/-60 Installation Instructions Other:.max size 46.5 x 46.5 FL12570 R2 II ISFGlnstallQCIS.pdf Verified By:James D.Wells.Jr. P.E.P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports FL12570 R2 AE 7 17'12 ISFG Approved Product Evaluation Report.pdf I Created by.Independent Third Party:Yes 12570.5 MD-CMA ;Curb mounted polycarbonate bubble with welded i aluminum ring. 2 of 3 5/29/2013 11:24 AM Florida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspN?paranr—wGEVXQ... Limits of Use Certification Agency Certificate { Approved for use in HVHZ:Yes FL12570 R2 C CAC MDCMANI006216-R4.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistantd Yes 04/30/2014 Design Pressure: +60/-60 Installation Instructions Other: max.size 22.5.x 46.5 FL125.70 R2 II MDCMAInstallsBCIS.pdf Verified By:James D.Wells Jr.P.E. P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports FL12570 R2 AE 6 6 12 Approved MD-CMA Prod Eval Report 003.pdf Created by Independent Third Party:Yes . fade Neat Contact Us::1940 North Monroe Street Tallahassee FL 32399 Phone:850-487-1824 . - The State of Florida is an AA/BO employer.Soovdaht 2007-2010-State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want youre-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address If they have one.The emags provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine iFyou are a licensee under Chapter 455,F.S.,please click here_. Product Approval Accepts; . ®EN 5ecurit NYj luL:S a 3 of 3 5/29/2013 11:24 AM NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NIO11087-R1 DATE: 05/02/2012 W j '' CERTIFICATION PROGRAM: Structural COMPANY: Sun-Tek CODE: 225-1 �i�o aAoG- .d REVISION DATE: 01/30/2014 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Sun-Tek Manufacturing,Inc. Series "HSF" Polycarbonate 10303 General Drive Aluminum Fixed Skylight Orlando,FL 32824 Configuration: O Glazing:Polycarbonate Outer Dome Thickness-0.093"/ Inner Liner Thickness-0.080" Frame: W-1385mm(54.5") H-1385mm(54.5") DLO: W-1182mm(46.5") H-1182mm(46.5") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure=+60/-60 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL 210-3716-1 Expiration Date: November 30,2017 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 Sun-Tek Manufacturing, Inc. INSTALLATION INSTRUCTIONS 10303 General Drive POLYDOME SERIES nnT Orlando, FL 32824 ��yy��Suek a 407/859-2117 MODEL HSF S K Y L I G H T S www.Sun-Tek.com + z,, Customer5ervice@Sun-Tek.com y = I • 0 Fastener Schedule Frame to Deco to Deck Frame Engineer of Record: . #8x1" #6x3-4"Hex Jame,D.Wells,Jr.,P.E. Finished Pan Head Head Self Professional Engineer Opening Fits on Screws Drilling Screws No.53616 Size Roof (Drywall Center Long Short Long Short Code Opening Dimension) Spacing Side Side Side Side J 8 L Wells Consulting LLC 1453 Arbitus Circle 1430 14'h"x 30W' 13%2"x 291/2" 16" Oviedo,FL 32765 (407)496-5489 1446 141;2"x 4642" 13b4"x 45'/2" 16" Certificate of Authorization No.27162 2222 22'/2"x 22'/2" 21 I/Vx 21:4" 24" 5 5 5 5 You will need: 2230 221,2"x 30!:2" 21'/2"x 291/2" 24" •hammer •sealant/mastic 2236 221/2 x 36'h" 21%2"x 35%" 24" keyhole saw tape measure skill sawn chalkline or straight edge 2246 22'h"x 46':4" 211/2"x 451/2" 24" 8 5 8 5 nails trowel or caulk gun 3030 30'/2"x 30:1,' 291h"x 29%2' 16"or 32" drill utility knife 2 x 4's 3046 30'/2"x 46';4" 294/2"x 45!%2' 16"or 32" 8 6 8 6 For Light Tunnel: RECOMMENDED SEALANTS: 3636 36'/2"x 36'/2' 35'h"x 351/2" 16"or 32" 7 7 7 7 8 or 10 penny nails 100%Silicone plywood or drywall Sealants approved for use on 4646 46'h"x 464, 45!h"x 4592" 16",32",48" 8 8 8 8 polycarbonate(contact Sun-Tek STS 1000(Sun-Tek exclusive)Butyl rubber sealant/caulk FAILURE TO FOLLOW RECOMMENDED INSTALLATION PROCEDURES MAY VOID WARRANTY Please read instructions completely before beginning. Deck and roofing felt should already be installed. 1 Inspect skylight for damage before installing.Peel back protective plastic to inspect dome.If skylight is damaged,do not install.Please contact your supplier for information on a replacement. 2 To properly position skylight between trusses/rafters,locate the \ roof opening from the underside of the decking.Drill holes or drive nails to mark corners.(If this area is not accessible,locate the ceiling joists from inside the house,mark and cut opening in A\\ ceiling,then mark roof opening.) 3 Remove shingles 6-8"out from roof opening. Before cutting roof opening,check measurements against size chart.Snap a chalkline from corner to corner,or draw line with a straightedge,then cut roof opening. q Frame roof opening using 2 x 4's as headers-cut two 2 x 4's to fit the actual distance between trusses/rafters and nail into place. E p a)If applicable,cut ceiling opening and build tunnel framing. . 53616 See"Light Tunnel Installation Instructions." pix= STATE OF ; 4 ice •' �tOBftO�` 5 Shingle up roof to bottom of roof opening. 6 Apply a 1/2"wide bead of caulking,set back 1"from the 5 roof opening around the entire opening.Set a second 1/2" 6 wide bead around the entire opening,set 1"back from the first bead.Sealant applied too close to the opening may"ooze"into the opening.Can also use 3"wide x%" thick butyl tape,if compatible,set 1/2"back from opening. Set skylight over opening.Screw into place through the pre-drilled holes in the flange with the#8 x 1"phillips pan head screws provided(See Fastener Schedule).Cover the head of each screw with sealant. IMPORTANT: Bottom flange of skylight MUST go on top of shingles. —\-- 8 Now shingle up sides and across top.Place shingles,as far in as possible,but be careful not to nail through skylight flange. 9 Bottom flange will still be exposed:we recommend leaving it this way.If you decide to put a"false shingle"over it,be careful not to nail through skylight flange. �® 10 Interior Finishing: Run drywall(or other finishing material) up the inside face of the skylight curb.Slip the drywall up until it bumps against the ledge in the top of the curb. Engineer of Record: James D.Wells,Jr.,P.E. Professional Engineer ? No.53616 / J&L Wells Consulting LLC 1453 Arbitus Circle !m Oviedo,FL 32765 = ; (407)496-5489 Certificate of r " Authorization No.27162 XV 10�Vet `���� �`�� �F'••`'i�iii' �„ ✓-'`-"". -``�- ��Y-- 5 616 t ?W t S 'ATE OF a F t WfAU 54.50 —4.00 ® - 6.75 �—m r 6.00 0 0 6.75 6.75 Engineer of Record: _a I� 0.63--- � James D.Wells,Jr.,P.E. �4 Professional Engineer — No.53616 J&L Wells Consulting LLC 1453 Arbitus Circle Oviedo,FL 32765 N (407)496-5489. CD Certificate of p Authorization No.27162 4to �— 32 FASTENERS FRAME TO DECK DESIGN PRESSURE RATING C:) ~ +_60 PSF f to to C° LARGE MISSILE IMPACT RESISTANCECD 1 to 4 coff'o LO f 32 FASTENERS DECO RING TO FRANE if MOM �j ,5 !� its, OUTER DOME.093 POLYCARBONATE t NO. 53616 lam- (GE LEXAN OR SHEFFIELD HYZOD"GP") i STATE OF rZ` INNER DOME.080 POLYCARBONATE(GE LEXAN OR SHEFFIELD HYZOD"GP") wa ZIJ� Q o �w II DESIGN PRESSURE RATING I o cwi +-60 PSF �LL j LARGE MISSLE IMPACT RESISTANCE I _� _Z O �64 _ 1 T 518 in penetration — Icp —ROOF DECK fib X 1"PHILLIPS PAN HEAD—� t ��$M'rw^s�t '. �b,�� ;'.r �'�°'' ♦.+,}.lit �,';'�:-at�ji ,y, �..ze�``'i•k i"�f'k`�p.ems,.,` � �"��' .���xc: Aper < �. ``h '� `n'�f.'• *+�- '•-4:.- Ai,.n'—� r �`�'-5�"'"A •� Engineer of ecoid: Eames D.Wells,Jr.,PE. Professional Engineer No.53616 J&L Wells Consulting LLC 1453 Arbitus Circle Oviedo,FL 32765 " �a+ x (407)496-5489 rz a .>• $ i Ort Certificate of RD Authorization No.27162 t Ell �`)r� sir ✓ "��gf - n���.r�,, • �T� - ;�� � ������ "�>� �. � ,".�� `,�� AVID W����o� dAWE ;✓,p si/� ,,;'"5�-��•�f� E`�,i�}� '1+� '� rz+�,.x rr�,x'�.�,k,�^�.v, "���=�,t� � �;.1r t �r� � 4» sIl l ,•,'moi/1{�'•�,��t?�i0� f�®��` CLEANING YOUR SKYLIGHT: ������\\ Use a mild glass cleaner(such as Glass Plus)and a clean sponge or soft cloth.Fresh paint splashes,glazing compound,etc.may be removed before drying by rubbing lightly with a soft cloth or cotton ball soaked in isopropyl alcohol. DO NOT use abrasive or highly alkaline cleaners,ammonia,benzene,gasoline,acetone,or carbon tetrachloride.Do not clean skylight in bright sun or high temperatures.Periodic waxing with a high quality,non-abrasive wax such as Mirror-Glaze will help maintain the good looks of your skylight. LIGHTTUNNEL INSTALLATION INSTRUCTIONS For homes with an attic,it is necessary to build a tunnel between skylights and ceiling.The tunnel walls may be straight,or Flared for extra light and architectural appeal.It's very easy to increase the tunnel size along the length of the ceiling joists.As long as no roof-supporting members are cut,no special framing isneeded.While itis possible to flare the tunnel in all directions,if support members are cut,special framing will be required forstructural support.In this case you must consult a qualified building professional to insure proper and safe results. 1 After roof and ceiling openings have been framed, measure distance (at each corner of roof opening)between rafter/truss and ceiling joist. 2 Using these four measurements,cut 2 x 4 lumber for vertical support members(two per corner). 3 In each corner,nail vertical support members into place at right angles to each other. 4 Measure,cut,and nail tunnel walls into place.Suggestions for lining tunnel: I i use drywall,tape corners,and paint white using regular or texture paint.(Texture paint alone will hide and fill untaped joints,but in time,cracks may appear in corners.) i use prefinished paneling with molding in corners. line the tunnel with cedar,pine,or a wood to coordinate with your decor. j„ \ for special effects,try painting the tunnel a striking accent color,or use mirrors or wallpaper on tunnel walls. \ 5 Caulk the slight gap between the tunnel walls and skylight base. 6 Finish off tunnel at ceiling with molding,or blend edges into ceiling with texture paint. 7 Be sure to wrap the exterior of the tunnel with insulation for energy savings. POLYDOME SKYLIGHT LIMITED WARRANTY Sun-Tek.Manufacturing,Inc.("Sun Tek")10303 General Drive,Orlando,Florida 32824,(407)859-2117,warrants this Skylight on the following terms and conditions:A.Warranty Coverage:This warranty applies to both the original purchaser and first consumer-owner of a Skylight made by Sun-Tek.B.Warranty Duration:This warranty shall remain in effect for a period of five(5)years on Model SF and ten f 10)years on all other Dura-Series models after the date the Skylight is purchased or the date the skylight is delivered to the first consumer-owner,whichever is later.One(1)year on electric components. C.Warranty Application:This warranty applies only to the materials and fabrication of the Skylight and does not apply to any defect or damage caused by improper use,improper installation,improper care,shipping damage or ac- cident.This warmntydoes not cover anycosmetic changes in skylight,including but not limited to pitting,hazing,paint finish,discoloration.Condensation or damaged caused by condensation is not covered underthis warranty. D. Performance by Sun-Tek:During the warranty period,Sun-Tek will provide free of charge an equivalent new skylight(or component thereof)for one found to be defective in material or uorkmanship.5hipping costs of such replace- ments are not the responsibility of Sun-Tek.Sun-Tek will not be responsible for any costs of removal or re-installation.E.Validation Procedure:To obtain performance under this warranty,the purchaser muse(1)on installed skylights, contact Sun-Tek for instructions before removing skylight.Removal of skylight from roof before inspection will void warranty.(2)Notify Sun-Tek in visiting of any claim within thitty t30)days after the defect is discovered:(3)Sor.-Tek or its authorized agents must examine high quality installedphotographs ohne subjeti slylight and deter mine to its satisfaction whether the defect is covered by this warranty;and(41 Present a copy of the receipt as proof of purchase.F. Implied Warranties:IMPLIED WARRANTIES,INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,SHALL NOT EXTEND BEYOND THE DURATION OFTHE EXPRESS WARRANTIES PROVIDED HEREIN.Some states do not allow limitations on how long an implied warrantylasts,so the above limitation may not apply to you.G.In cidental or Consequential Damages:SUN-TEK SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER,INCLUDING BUT NOT LIMITED TO LOSS Of TIME OR REVENUE,DAMAGE RESULTING TO OTHER PROPERTY OR OTHER EXPENSES.Some states do not allow the exclusion of limitation of Incidental or consequential damages,so the above limitation or exclusion may not apply to you.H.Exclusive Warranty:THIS WARRANTY is EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES.This warranty gives you s ecificle alit hts-Youma have other ri hts which var from state to state. All installation information is supplied in good faith,but without recommendation to its use.No guarantee of the results of any use of this information is to be implied,since conditions of use are beyond our control.Please consult local building codes for compliance before installing.