Loading...
HomeMy WebLinkAboutEngineering ENGINEERING Terrence E. Lunn,PE,FCSL CCS 2213 22nd Lane Palm Beach Gardens,FL 33418 (561) 625-6455 Fax (888) 788-2515 e-mail: terry@telunnpe.com Three Guys Roofing, Inc. 700 Uno Lago Dr. #103 Juno Beach, FL 33408 May 26,2015 Residence 1902 S 34th Street, Fort Pierce, FL 34947 Calculations in accordance with FL RAS 117 Roofing System to be used: Polyglass USA Self-Adhesive NOA Number 13-1217.01 Page Number 22 Base sheet size 65 ft 39.37 Lap size 4 in Fasteners #14 Dekfast Screw with plate Fastener spacing in lap 12 inches 1 Total # of rows 3 Fastener spacing in field 12 # of rows 2 Rated Pressure -52.5 psf Net width and 35.37 in length of sheet 33.93 ft Row spacing 11.8 m Number of fasteners per 100 sq.ft. 101.8 Number of sq.ft. per fastener 0.98 sq.ft. Determine fastener value -51.58 lbs Design Pressures Zone 1 -27.7 psf Perimeter Zone 2 -46.4 .psf Comer Zone 3 -69.8 psf Required base sheet fastener spacing to meet design pressures Zone 1 12 mi %'011111111 os�i Zone 2 12.0 in Zone 3 9.0 in �� �, SF•.�G�'�� : STATE OF • May 26 201516:23:56 r, Prepared by T.E. Lunn,PE,LLC FL 26119 5/26/2015 Membrane: One ply of Polyfresko G SBS SA,Polyfresko G SBS SA FR,Polyfresko G APP SA, Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex SA P,PolyKool,XtraFlex Kool APP S SA,Polyflex SA P FR or XtraFlex APP G SA,self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf;(See General limitation V.) NOA No.: 13-1217.01 MIAMICOUNTY FINE Me no Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 25 of 33