Loading...
HomeMy WebLinkAboutBuilding Permit Application Florida Building Code Online Page 4 of 5 Design Pressure:+36 PSF/-42 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FI.1.61.07 R5 AE CBPC 1.41.219-A.odf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.12 12 W6-18 PAN-21`153: 73,75,84A, Steel Pan(min.25 ga.)Double-Car(16'4"to 18'2"wide) 94,42,48,42B,48B,4RST,6RST, WINDCODEO W6 Garage Door GOSS,GR5S,AR5S,ED5S Limits of Use Installation Instructions Approved for use in HVHZ:No 171.1.61.07 R5 11 1.04761.-B-IBC-Rev04.odf Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:No Created by Independent Third Party: No Design Pressure:+36 PSF/-42 PSF Evaluation Reports Other:Doors with standard glazing meet the wind load FL16107 R5 AE CBPC 141219-A.odf requirements of the building code but DO NOT meet the Created by Independent Third Party:Yes impact resistant requirement for windborne debris regions. 16107.13 13 W7-18 PAN-2F143: 84A,94,98, Steel Pan(min.24 ga.) 16'4"to 18'2"wide WINDCODE@ 48,48B,4F,4RST W7 Garage Door with Optional Impact-Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R5 II 1.04762-IBC-Rev02.odf Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+41 PSF/-46 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R5 AE CBPC 121212-A.I.odf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.14 14 W8-16 DSIE-11`171: HDG, Double-skin Insulated(exterior skin 27 ga. min.; interior HDGL,4300,4310,4301,66,66G, skin 27 ga.min.)Double Car(9'2"to-16'2"wide) 67,67G,68,6200,6201,6203, WINDCODEO W8 Garage Door with Optional Impact- - SP200,SF200,SE200 Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R5 11 104736-IBC-Rev03.odf Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+46 PSF/-52 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH. Solid doors or FL.16107 R5 AE CBPC_]30214-A.odf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.15 15 W8-16 PAN-2F143: 84A,94,98, Steel Pan(min.24 ga.) Double Car(9'2"to 16'2"wide) 48,48B,4F,4RST WINDCODE@ W8 Garage Door with Optional Impact- Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R5 II 104754-IBC-Rev02.odf Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+46 PSF/-50 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FI-1.6107 R5 AE CBPC 1.21212-A.l.odf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.16 16 W8-18 DSIE-11`171: HDG, Double-skin Insulated(exterior skin 27 ga.min.; interior HDGL,HDGF,4300,4310,4301, skin 27 ga. min.)Double Car(16'4"to 18'2"wide) 66,66G,67,67G,68,6200,6201, WINDCODE@ W8-Garage Door with Optional Impact- 6203,SP200,SF200,SE200 Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R5 1I 104752-16C_Rev02.I)df Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+46 PSF/-50 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R5 AE CBPC 121212-A.l.odf doors with optional impact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). 16107.17 17 WB-16 DSIU-11`171: 9200, Double-skin Insulated PUR(exterior.skin 27 ga. min.; 9201,9203,HDP20,HDPF20, interior skin 27 ga. min.)Double-Car(97"to 16'2"wide) HDPL20,7200,7201,7203,8200, WINDCODE@ W8 Garage Door with Optional Impact- 8201,8203 Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16107 R5 II 104778-IBC-Rev03.odf Approved for use outside HVHZ:Yes Verified By: Mark Westerfield FL PE 48495 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+46 PSF/-52 PSF Evaluation Reports Other:Max.Wind Speed(V_ult): 170 MPH.Solid doors or FL16107 R5 AE CBPC 130214-A.Pdf doors with optionalimpact-resistant glazing are impact- Created by Independent Third Party: No resistant(large missile impact). http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvyf4ngAXh 109... 4/27/2015 These Tables Are For GARAGE DOORS IN One and Two Family Dwellings Garage Doors Installed In Buildings with a Mean Roof Height of 30' or Less Located in Exposures B,C or D Table R301.2(4) COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF] ❑160 EXPOSURE B 9'x 7'Door =+26.7 -30.2 1-1160 EXPOSURE B 16'x T Door =+25.6 -28.5 1771160 EXPOSURE C 9'x 7' Door = +32.4 -36.6(1 story and max 15' F11 60 EXPOSURE C 16'X 7'Door =+31.0 -34.5 mean roof height) ❑160_EXPOSURE C_ 9'x 7' Door +37.4 -42.3 (2 story and max 30' . 01;60 EXPOSURE G 16'X T Door +35.9 -_9 9 mean roof'height) 0160 EXPOSURE D 9'x 7' Door=+39.3 -44.4 .(1 story and max 15' M160 EXPOSURE D 16'x 7' Door=+37.7 -41.2 mean roof height) ❑160 EXPOSURE D 9'x 7'Door=+44.3 -50.2 (2 story and max 30' 171160 EXPOSURE D 16'x 7'Door=+42.5 -47.4. mean roof height) r-11 50 EXPOSURE B 9'x 7' Door =+22.8 -25.8 ❑150 EXPOSURE B 16'x 7'Door =+21.8 -24.3 ❑150 EXPOSURE C 9'x 7'Door=+27.6 -31.3 (1 story and max 15' 1-1150 EXPOSURE C 16'x 7' Door=+26.4 -29.5 mean roof height ❑150 EXPOSURE C 9'x 7'Door=+32.0 -36.2 (2 story and max 30' ❑150 EXPOSURE C 16'x 7'Door=+30.6 -34.1 mean roof height) 171150 EXPOSURE D '9'x 7'Door =+33.6 -38.0 (1 story and max 15' 1-711 5o EXPOSURE D 16'x'7'Door =+32.1 -35.8 mean roof height) Ell 5o EXPOSURE D 9'x 7' Door =+37.9 -42.9 .(2 story and max 30' ❑150 EXPOSURE D 16'x T Door =+36.2 -40.4 •mean roof height) Notes: ■ Secure existing bucks per the Product Approval or Design Professional Instructions prior to installing the door. Have product-approvals available at the time of inspection. ■ Glazing in Garage doors must comply with R301.2.1.2 (Glazing must be impact resistant or shuttered) Miami Dade N.O.A or Florida Product Approval 9 �� ,