HomeMy WebLinkAboutNotice of Acceptance MIAMI-DADS COUNTY MIAMI-DADS PRODUCT CONTROL SECTION ME 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Pro-Startrm Starter Strip and WeatherBlockeem Premium Eave/Rake Starter Strip LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERIVIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. ailure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dadelorida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOe;e ed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufac distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1104.02 and consists of pages 1 through 5. The submitted documentation was reviewed by Juan E.Collao,R.A. .600-4-17 NOA No.: 14-1022.15 QMIAMDAIRouNr�r Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 1 of 5 5 J ROOFING ASSEMBLY APPROVAL Cateeory Roofing i Sub-Catezory: Asphalt Shingles Material: Laminate Deck Type: Wood 1. SCOPE This approves GAF Pro-StartTm Starter Strip and WeatherBlockerTM Premium Eave/Rake Starter Strip manufactured by GAF as described in Section 2 of this Notice of Acceptance, designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description GAF Pro-Starfrm Starter 13"x 38" TAS 110 Prefabricated starter strip asphalt shingle. Strip Shingles Manufacturing Locations#1, 2, and 3 GAF WeatherBlockeeld 17"x 40" TAS 110 Prefabricated starter strip asphalt shingle. Premium Eave/Rake Starter Strip Manufacturing Location#2 2.1. MANUFACTURING LOCATIONS 1. Dallas,TX 2. Mt.Vernon,IN 3. Tuscaloosa,AL 2.2. EVIDENCE SUBMITTED Test Aeencv Test Identifier Test Name/Report Date PRI Asphalt Technologies,Inc. ELK-34-02-01 TAS 100 05/16/00 Underwriters Laboratories,Inc. OINK06632 ASTM D 3462 02/01/01 94NK9632 TAS 107 03/29/00 OONK32754 ASTM D 3462 08/11/00 09CA06856 . ASTM D 3462 05/15/09 10CA07264 ASTM D 3462 05/27/10 IONK11953 ASTM D 3462 10/29/10 NOA No.: 14-1022.15 MIAMI•DADE COUNTY Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 2 of 5 i 3. LINIITATIONS 3.1 Fire classification is not part of this acceptance. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3.2 Shall not be installed on roof mean heights in excess of 33 ft. 3.3 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Starter Strip Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 4.2 The manufacturer shall provide clearly written application instructions. 5. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY 6. BUILDING PERMIT REQun www: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-1022.15 MIAMI•DADB COUNTY Expiration Date: 08/09/16 Approval Date: 02/05/15 Page 3 of 5 v GAF PRo-START-STARTER STRIP SHINGLE 38" 5/8" 13" - - - - - - - - - - - - - - - - - � 4 11/16" BACK VIEW 61/2"T}p Each shingle preforated on q as shown 1 1/16" — — — — — — — — — — — — — — — — TOP VIEW NOA No.: 14-1022.15 MIAMI-DADE COUNTY Expiration Date: 08/09/16 . Approval Date: 02/05/15 Page 4 of 5 t ' GAF WEATHERBLOCKER—PREMIUM EAVE/RAKE STARTER STRIP o•(1,06MM) I — Self Seal (216mm) /— — — — — — — —--- — — — - 17" ------ ------ ------ -- (432mm) 8.5' \—Perforatlon (216mm) END OF THIS ACCEPTANCE NOA No.:14-1022.15 MIAMI•DADE COUNTY Expiration Date: 08/09/16 e Approval Date: 02/05/15 Page 5 of 5 MIAMI- MIAMI-DARE COUNTY Mkils Y PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy GAF 1361 Alps Road. Wayne,NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHD(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION. e. - ' e®a GAF Timbertexg Ridge Cap Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Fa'ure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade C orida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NO is ed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the in ac er or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-01011.14 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. NO � 0306.08 MLAMI-Dace cour�rr Expiration Da. 10/17/17 Approval D /15/13 Page 1 of 9 i ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Asphalt Shingles Materials 3-Tab Perforated Deck Type: Wood SCOPE This approves GAF Seal-A-Ridge®and GAF Timbertex®Ridge Cap Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Seal-A-Ridge®Ridge Cap 12"x 36" TAS 110 Hip and Ridge asphalt shingle with two Shingle perforations 12 inches o.c. along the 36"length Manufacturing Location#1,3 of shingle. GAF Timbertex®Ridge Cap 12"x 12" TAS 110 A 12"x 36"prefabricated hip and ridge Shingle fiberglass reinforced asphalt shingle with Manufacturing Location#2 perforations at 12"sections. PRODUCTS MANUFACTURED BY OTHERS Product Product Size Manufacturer Description PL Polyurethane Roof&Flashing Sealant various Henkel PL Sealant NP-lTM Sealant various Sonneborn MANUFACTURING LOCATION 1. Tuscaloosa,AL. 2. Mt.Vernon,IN. 3. Mobile,AL. NOA No.: 13-0306.08 MIAMI•DADE COUNTY �wguy.,tsynal Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 2 of 9 EVIDENCE SUBMITTED Test ALenc Test Identifier Test Name/Report Date PRI Asphalt Technologies,Inc. TAS 100 ELK-078-02-01 06/21/02 TAS 100 GAF-125-02-01 04/04/06 Underwriters Laboratories,Inc. ASTM D3462 11CA45079 03/21/12 ASTM D3462 06CA18074 06/16/06 ASTM D3462 12CA30878 02/01/13 TAS 107 11CA45079 03/21/12 TAS 107 06CA18074 06/16/06 TAS 107 12CA38083 02/26/13 PRI Construction Materials Technologies LLC TAS 100 GAF-380-02-01 11/06/12 TAS 100 GAF-367-02-01 07/12/12 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. GAF Seal-A-Ridge® and GAF Timbertex®Ridge Cap Shingles shall be limited for use as hip and ridge cap shingles only. 3. Shall not be installed on roof mean heights in excess of 33 ft. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION 1. GAF Seal-A-Ridge®and GAF Timbertex®Ridge Cap Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Nailing for GAF Seal-A-Ridge® Ridge Cap Shingles shall be in compliance with Detail `A' attached. Exposure and course layout for GAF Seal-A-Ridge® Ridge Cap Shingles shall be in compliance with Detail W. 5. Henkel PL Polyurethane Roof& Sealant or Sonneborn NP-lTM GunGrade must be used in the application of GAF Seal-A-Ridge® Ridge Cap Shingles as specified in Detail A and GAF Timbertex®Ridge Cap Shingles as specified in Detail B. 6. Nailing for GAF Timbertex® Ridge Cap Shingles shall be in compliance with Detail `B' attached. Exposure and course layout for GAF Timbertex®Ridge Cap Shingles shall be in compliance with Detail `B'. NOA No.: 13-0306.08 QMIAMOADROUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 3 of 9 LABELING 1. Shingles shall be labeled with the Miami-Dade Seal as seen below,or the wording'Miami-Dade County Product Control Approved". MIAMI•DADE COUNTYIN BUILDING PERMIT REQUII mms 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 13-0306.08 MIAMMAD,COUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 4 of 9 DETAIL A GAF Seal-A-Ridge®Ridge Cap Shingles Application Instructions: (1)Step One—Separate each piece of GAF Seal-A-Ridge®Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations(see Figure 1). Figure 1 1x°(12 mm) 1 12' (305 mm) i 6Z N. Exposure (169 MM) 12' Per,'crated 36' (914 mm) (2)Step Two—Begin laying full ridge cap shingle with a 6-2/3"exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind(see Figure 2). Figure 2 a �1 213 \ \ `691 Fastener \ \ f \ � J MIAMI•DADE COUNTY NOA No.: 13-0306.08 •••. Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 5 of 9 (3)Step Three—Apply ridge cap using 2 nails per piece 6-5/8"to 7-5/8"back from the exposed end and 1"to 2"up from the edge(see Figure 2 for location of nails).Use only zinc coated steel or aluminum, 10- 12 gauge,barbed,deformed or smooth shank roofing nails with heads 3/8"(9.5mm)to 7/16"(12mm)in diameter. Nails should be long enough to penetrate at least 3/4"(19mm)into wood decks or just through plywood decks. Nails must be driven flush with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Special Application Section: For Cold Weather Application • In cold weather,warm GAF Seal-A-Ridge®Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather,apply quarter-sized dabs of asphalt plastic cement(must conform to ASTM D4586 Type I or Type II)between ridge cap pieces and press firmly to insure good contact between pieces. • Note.Excessive application of tab adhesive can cause blistering of ridge cap shingle. For High-Wind Zones • In high wind areas or for maximum wind resistance,apply a two quarter-sized dabs of Henkel PL®Urethane Sealant to each ridge cap shingle approximatly 9"back from the exposed end and 1"from the shingle edge. (see Figure 3). Figure 3 11.5' Sealant 1" (292 mm) 1" Sellante (25 mm) (25 In Enduit d'6tanch6it6 Nail Clavo 12" Clouer (305 mm) 9. (229 mm) 12" (305 mm) For maximum wind speed coverage under ltd.warranty,apply additional sealant as shown.See Special Application Section for specific details. Para el alcance maximo de velocidad de viento bajo limitado garantia,aplica sellador adicional coma mostrado.Vea Secci6n Especial de Aplicaci6n para detalles especificos. Pour la couverture mai rnum de vitesse de vent sous limit6.la garantie, appliquer de 1'enduit d'dtanch6it6 suppl6mentaire comme indiqu6. Voir la section spdciale d'application pour les d6tails sp6cifiques. NOA No.: 13-0306.08 MIAMI•DADE COUNTY •U•• Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 6 of 9 . DETAIL B GAF Timbertee Ridge Cap Shingles Application Instructions: (1)Step One—Separate each piece of GAF Timbertee Ridge Cap Shingles into three individual ridge cap shingle pieces at perforations(see Figure 1). Figure 1 (905mm 705mm) I (305mm) Self-Seal 1 1_ Adhesive 4'(-1o2mni) 1 i on Back - Adhesivo Auto- 1. J�.1 Sellante en la 8' ) 1 Perforations. 1 Parte.Posterior l Perforaciones 1 AdhesifAuto- (203mm 1. .Perforations: 1- SoeIlantA R C'Endos Self-Seal Adhesive on Bade Bott&n.backei- Adhesivo;Auto-Sellante en la.p,419.Posterioi- Apoyolnferior Adhesif Autd-Sbellant-A.L'Endos Appui lnfdrieur (2)Step Two—Prepare the starter course...For this step,take a 12"x 12" (305mm x 305mm)ridge cap piece and cut along the line between exposure and headlap(see Figure 2). Figure 2 Exposure. 203 mrn Nail 9"(229;mm)from bottom Starter Course & 1"(25 mm)from edge Bottom Backer Self-Seal Adhesive on Back NOA No.: 13-0306.08 MIAMI-DAD;COUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 7 of 9 (3)Step Three—Place the 4"x 12" (102mm x 305mm)starter cap across the ridge starting at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. Note:For cold weather application or for high wind zones see special application section below. (4)Step Four—Begin laying full ridge cap shingle pieces 12"x 12" (305mm x 305mm)as shown(see Figure 2). Apply with an 8"exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing wind. (5)Step Five—Apply ridge cap using 2 nails per piece 9"back from the exposed end and 1"up from the edge(see Figure 3 for location of nails).Use only zinc coated steel or aluminum, 10-12 gauge,barbed, deformed or smooth shank roofing nails with heads 3/8"(9.5mm)to 7/16"(12mm)in diameter. Nails should be long enough to penetrate at least 3/4"(19mm)into wood decks or just through plywood decks. Nails must be driven flush.with the surface of the shingle. Over driving will damage the shingle. Raised nails will interfere with the wind resistance of the shingles. Figure 3 12"(305mm) Top Laminated Piece 4r Pieza SuperiorLaminadL 102mm Pike Laminee Superieure �1'(25mrn) f 0mm) Nail Fold Line Nail Clavo Linea de Pliegue Claw Clou Ligne De Pliage Clou $r 203rnm Special Application Section: For Cold Weather Application • In cold weather,warm GAF Timbertex®Ridge Cap Shingles before bending. • When self-sealing is delayed due to cold weather;apply quarter-sized dabs of asphalt plastic cement(must conform to ASTM D4586 Type I or Type II)between ridge cap pieces and press firmly to insure good contact between pieces. • Note.Excessive application of tab adhesive can cause blistering of ridge cap shingle. NOA No.: 13-0306.08 QMLAAMI-DAD;COUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 8 of 9 For High-Wind Zones • In high wind areas or for maximum wind resistance,apply a'/4"wide bead of Henkel PL® Urethane Sealant or Sonneborn®NP-l"m Urethane Sealant to each ridge cap shingle%"-1"from the shingle edge,parallel to the ridge(see Figure 4). Figure 4 T 12"(305mm) Top Laminated Piece71 q� Piem Superior Lamina& 102mm Piece Laminee Superieure It1°(25mm) 1"(25rnm)� I Nail Fold Line Nail Clavo Linea rk Pliegue Claw Clou Ligne N Pliage Clou 8` 203m m END OF THIS ACCEPTANCE NOA No.: 13-0306.08 Mu �•uaoe COUNTY Expiration Date: 10/17/17 Approval Date: 08/15/13 Page 9 of 9 MIAMI DADE COUNTY MIAMI-DADE PRODUCT CONTROL SECTION °® 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD®,Timberline Natural Shadow®,and Timberline American Harvest® Shingles LABELING:Each unit shall bear a permanent label with the manufacturer's name-or logo,city,state and following statement: "Miami=Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERIVIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, florOwwfind followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displ en it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or l tributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0419.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E.Collao,R.A. 0 CMIAMI. ADE COUNTY NOA No.: %06 Expiration Date:0 Approval Date:0 Pag ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®,Timberline Natural Shadow°,and Timberline American Harvest® Shingles as manufactured by GAF as described in Section 2 of this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 '/;x39 /8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle,with a laminate profile Locations#1,2,3,4,5,6,7 GAF Timberline Natural 13 '/4"x 39 3/;' TAS 110 Fiberglass reinforced heavy weight asphalt Shadow® roof shingle,with a laminate profile Manufacturing Locations#1,2,3,4,5,6,7 GAF Timberline American 13 '/4"x 39 3/g» TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle,with a laminate profile Manufacturing Locations#2,4,5,6 MANUFACTURING LOCATION 1. Tampa,FL 2. Michigan City,IN 3. ' Baltimore,MD 4. Myerstown,PA 5. Ennis,TX 6. Tuscaloosa,AL 7. Dallas,TX NOA No.: 14-1022.20 MIAMI•DADE COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 2 of 6 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/24/11 Underwriters Laboratories,Inc ASTM D3462 10CA21994 04/22/11 Underwriters Laboratories,Inc ASTM D3462 10CA28717 07/26/11 Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06 Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories,Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94 Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-086-02-01 10/24/02 ELK-087-02-01 10/21/02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.:14-1022.20 MLAMI-Dane CO j Expiration Date:02/21/17 Approval Date:02/05/15 Page 3 of 6 s INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail'B',attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility,and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 14-1022.20 MIAMI•DAD;COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 4 of 6 DETAIL A COURSE LAYOUT DECK FULL 5th 17"OFF 4th 11"OFF 3rd 6" OFF 2nd FULL 1st NOA No.: 14-1022.20 Mwr��•�e courirr Expiration Date:02/21/17 Approval Date:02/05/15 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN low 39-3/811 (IM) 14-1/71-17-1/211 14-1/2"-17-112 (368-445mm) (368-445mm) 6-1/2"-9-1/2" 6-1/2"-9-1/2" ail guide line �_� /4"" (166-241mm) (165-241mm) 6-3/4'-6-1/4" (337m ) (146mm-159mm) 1rz°-2-V2" from bottom of shingle elf seal adhesive on back ENHANCED NAILING PATTERN -six nails per shingle* 'required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6"(152mm)from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE NOA No.: 14-1022.20 aMRS-141,151 COUNTY Expiration Date:02/21/17 Approval Date:02/05/15 Page 6 of 6