HomeMy WebLinkAboutProduct Approval EXTERIOR RESEARCH & DESIGN, LLC.
0Q �{ Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
TRINITY ER® f OXFORD, CT 06478
PHONE: (203) 262-9245
ZA ..
FAX: (203) 262-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R4
One Owens Corning Parkway ;= FL10674-R9
Toledo, OH 43659 Date of Issuance: 02/06/2012
Revision 4: 03/04/2014
SCOPE: ,
This Evaluation Report is issued under Rule 9N-3 andiitho,applicable rules and regulations governing
the use of construction materials in the State of Florida' The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the p�ft under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 FBC and 2010 FBC Residential Volume sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This. Evaluation Report is valid until such time as the named product(§)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
~_= The facsimile seal appearing was authorized
by Robert Nieminen,P.E.on 03/04/2014
This does not serve as an electronically signed
Robert J.M. Nieminen P.E. %Fs,• �; h document. Signed,sealed hardcopies have been
transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 '="d""""""' to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
QOTRINI-ry I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the Florida Building Code and Florida Building
Code, Residential Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007
3. REFERENCES:
Enti Examination Reference Date
UL LLC (CER9626) Physicals &Wind Resistance File R2453,Vol. 3 02/15/2007
UL LLC (CER9626) Physicals &Wind Resistance 20120516-112453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals &Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter .02/13/2014
Miami-Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic° and Supreme° are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire° are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire TM are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration°, TruDefinition° Duration°, Duration° Premium Cool, TruDefinition° Duration°
Designer Color Collection, TruDefinition° Oakridge°, Oakridge° and WeatherGuard° HP are
fiberglass reinforced, laminated asphalt roof shingles.
4.2 Berkshire° Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard° HP Hip
& Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeTm Hip & Ridge Shingles are
fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.3 Wind Classification:
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 2 of 7
QOTP..INITYIERD
5.3.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating
the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (Vit = 194 mph).
Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 All Owens Corning hip & ridge shingles and Starter Strip Plus noted herein are Classified in
accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the
shingles are acceptable for us in all-wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer
to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60
feet or less. Calculations by a qualified design professional are required for conditions outside
these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.3.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the
Florida Building Code and F.A.C. Rule 9N-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide
Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4
or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published
instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2
or R905.2, with the following exceptions:
➢ Berkshire° shingles require minimum five (5) nails per shingle.
➢ WeatherGuard° HP shingles require minimum six (6) nails per shingle.
➢ Devonshire TM shingles require minimum six (6) nails per shingle.
➢ Starter Strip Plus requires minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of
fastening are required. Contact the shingle manufacturer for details.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization#9503 FL10674-119
Revision 4: 03/04/2014
Page 3 of 7
TRINITY I ER®
6.2.5 Minimum Nailing - Classic@ &Supreme:
Normal Mansard or Area para Wortnal Mansard or Area Para
Wind Areas High Wind desvanes y Wind Areas High Wind desvages y
Area para vientos norm®lea Areas.."' vientos fusrtes Area para vientos normales.Areas, vientos fuertes
5"Exposure 5.5/8'Exposure
!arposicion Exposicidn
6.2.6 Minimum Nailing - Berkshire@:
Sealant:suip-. Sealant ship
taaUa'de seRadw, to trra do w1fador.
t=,�pE--tea�—i • E a�--►a eE-0 s —r ra: a�—r.a-----------.e
LL
$Y� �
.2!" Asplaft roofing aanent
CenreAto;datubede astOd
6.2.7 Minimum Nailing - DevonshireTM:
401
w
Nails
r^ r a a• r r r r r r r
Asn• a• iy n•
S'N' B!:' SS' 61:•
Nails Ten f"S ots of Asphak Roof Cement
6.2.8 Minimum Nailing - Duration@, TruDefinition@ Duration, Duration@ Premium Cool &
TruDefinition° Duration° Designer Color Collection:
4;Nal Pateir fi Na1"r`n 'a eaand[op oSf ne t o d11;
6
Patte VIM
Esme4 cavos
Su[eNail°fastenin area width" EsguPma!, — d8uxarda_oytrm`Qntex
9 de ficlavoS 9udasfipde«r169PJ
Area detlaPasSureNad°' .s :.e a artasureNa�rbparft'.
:SUfeNaiP
armw
:areawtaUt -:� .. `.ksteriittrgn
:IT _ i:?"" � ,Arta de 1" .. :. ♦.T:`'.• s2.,
.LhVOS: 1 ,� �ttaw •
:Sur11r,e7lalP
SW Exposyie 5§�"rxposure
Nails
9c&'pulg de expoveigri. Ga1'os S�hPulg de exposrcldn;.
55k Exposure Naris 15%..
5% Exposure
5j�prilg.de erposieidri.. Davos S4,1,.de exposlckFrr
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-114
Certificate of Authorization#9503 FL10674-119
Revision 4: 03/04/2014
Page 4 of 7
TRINITY I ER®
6.2.9 Minimum Nailing - TruDefinitionO Oakridge@, Oakridge@:
4 Nail Rattern 6Nai1 Patterim
Fsgriema con 4 clayos Esguema 00 q"
r- t'
5 518"Exposure, s �5 518 Exposun
Naris_ Nails;
Expo,jd nde65/Sp,Ig W Fxposrctgrrife55/rpulg, 55/8 Eitposun3 Clavus 5518 Exposure
Fxposrepn de 5 5/BPalg:: Exposrudn de:5 518 ping..
6.2.10 Minimum Nailing - WeatherGuard@ HP:
�Inpl�;6ltyw
-'"J� -�� 1VIiE�lnhrnir
.�: £,. t• Rft�nr7lnw�Nil LiN
cr.Y..,a ..�; d�
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire° Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant,
WeatherGuard° HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply
with the manufacturer's current published instructions, using four (4) nails per shingle.
Installation of DuraRidgeTm Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand-sealing
for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less
than FBC 1507.2.6 or R905.2.5. Staples are not permitted.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate ofAuthorization#9503 FL10674-119
Revision 4: 03/04/2014
Page 5 of 7
QOTPuN IW I ERD
6.3.3 Minimum Nailing - Berkshire@ Hip & Ridge and High Ridge:
Fig.1.
.�,.;Pnvapgg VNnd .
Diredinn .p.. TonlrewSiifeVev�
Nails ? Nails Nails .
Top Lamriated
Place
I 1 I I 1
;o. I
1
$. yl
Exposure ,.�1
I
1
I
I
6.3.4 Minimum Nailing - Hip & Ridge with Sealant:
;ertr F High Vftlltxf Fac�trling;Ra�ttem:'
Exp:
6.3.5 Minimum Nailing - WeatherGuard@ HP Hip and Ridge:
Ffg.'A q. Fig G Hip'&Ridge Shngle'Fastening
PreVaIling,Wing .: TopVtevi
Nails _ „:4:4• .
A i, I NallS NOW
•- L I ` I I i 2 lu,
.-
1,
Exposure
6.1, exposure.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R4
Certificate of Authorization#9503 FL10674-R9
Revision 4: 03/04/2014
Page 6 of 7
TRINITY j ERD
6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing Standard Ott°
Wind DirectionFastening
Sealant Strip Pattern
g'Exposure to f^� +1°
12° � Sealant
Fasten 71h" 7'�=
I 6°Exposer®
Cover EMP osed i 1
Fasteners with
Roof Cement
6.3.7 Minimum Nailing — DuraRidgpl" Hip & Ridge Shingles.:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to
Owens Corning published installation instructions for their minimum requirements.
FFaraiingllFirdDiroam TopVlew
dira�iAndxnimntu[Lsnnt I- VEsms�erbr
dimaitn del rimme�3xnimnta
cw
ttaih �+ 2%' i. OrrcmiCani�_�ioNetT'- ,a. [mro
mater
I I
a I I sl�
4
°®Int"
�`
I
7. LABELING:
7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo
of the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications
detailed in FBC Table 1507.2.7.1 / R905.2.6.1.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule
9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-114
Certificate of Authorization#9503 FL10674-119
Revision 4: 03/04/2014
Page 7 of 7
L E
CO3PRESEARCH & DESIGN, LLC.
A -�-y Certificate of Authorization #9503
TRII VII 1 ERD 353 CHRISTIAN STREETXFORD,,CT 1QO6478
PHONE: (203) 262-9245
A. FAX: (203) 262-9243
EVALUATION REPO
Allied Building Prod Corp / Evaluation Report A42960.10.12-R1
TRI-BUILT Roofing rods* 9: FL16048-R1
9050 Louisiana Street " ., }�" ''� Date of Issuance: 10/25/2012
Merrillville, IN 46410 ;" Revision 1: 08/27/2013
SCOPE:
This Evaluation Report is issued underiRule 9N:r3yand the applicable rules and regulations governing
the use of construction materials in the State of
Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of ,the"r duct under the Florida Building Code and
Florida Building Code, Residential Volume. hie s described herein have been designed to
comply with the 2010 Florida Building Code sections no erein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: l'k
- :{��0_.,_'o-544Y!S •iii
_ a
+ :C: The facsimile seal appearing was authorized
by Robert Nieminen,P.E.on 08/27/2013
W.-�; c This does not serve as an electronically signed
Robert J.M. Nieminen P.E. ` •" ^^ document. Signed,sealed hardcopies have been
�jj,�,����n•,i transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE1983 G� to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which
the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
Q0TRINRYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by Allied Building Products
Corp., have demonstrated compliance with the following sections of the Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation
Requirements and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, 1507.2.9.2, 1507.3.3, .Physical Properties ASTM D1970 2001
1507.5.3
1504.6 Accelerated Weathering ASTM G155 2005
1504.3.1 Wind Uplift FM 4474 2004
1507.3.3 Installation Practice FRSA/TRI 07320 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD (TST6049) Physical Properties P33360.06.10 07/01/2010
ERD (TST6049) Physical Properties P33370.03.11 03/02/2011
ERD (TST6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST6049) Physical Properties P369.09.11 09/01/2011
ERD (TST6049) Physical Properties P37300.10.11 10/19/2011
FM Approvals (TST1867) Wind Uplift 3004091 01/12/2000
PRI (TST5878) Physical Properties PUSA-083-02-01 07/01/2008
UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 02/27/2012
UL, LLC. (QUA9625) Quality Control Multiple-Listing Agreement 04/12/2012
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/24/2015
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 Tri-Built Granular-P Shingle Underlayment is a nominal 60-mil thick rubberized asphalt
waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM
D1970.
4.1.2 Tri-Built Tile and Metal HT Underlayment is a nominal 60-mil thick dual-layer rubberized
asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets
ASTM D1970 and TAS 103.
4.1.3 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-
surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri
Certificate of Authorization#9503 FL16048-Rl
Revision 1: 08/27/2013
Page 2 of 6
TP,uNITY(ERD
5.3 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product
is specifically referenced within FBC approval documents. If not listed, a request may be
made to the AH] for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.4 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1: ROOF COVER OPTIONS
Asphalt Foam-On Wood
Underlayment Shingles Nail-On Tile Tile Metal Shakes& Slate
Shingles
Tri-Built Granular-P Shingle Yes No No No Yes Yes
Underlayment
Tri-Built Tile and Metal HT Yes Yes Yes Yes Yes Yes
Underlayment See 5.4.1
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
5.4.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile
adhesion / long term aging data from an accredited testing laboratory is provided.
➢ Tri-Built Tile and Metal HT Underlayment with Polyfoam PolyPro AH160
➢ Tri-Built Tile and Metal HT Underlayment with Dow TileBond
5.5 Allowable substrates are noted below:
5.5.1 Direct-Bond to Deck:
Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment
applied to:
➢ New untreated plywood;
➢ ASTM D41 primed new untreated plywood;
➢ Existing plywood;
➢ ASTM D41 primed existing plywood;
➢ ASTM D41 primed OSB;
➢ Southern Yellow Pine;
➢ ASTM D41 primed Southern Yellow Pine;
➢ ASTM D41 primed structural concrete;
➢ Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads
for project).
Note:Allied Building Products Corp. does not require priming of new or existing plywood sheathing for use
with Tri-Built Granular-P Shingle Underlayment or Tri-Built Tile and Metal HT Underlayment. New or
existing plywood sheathing should be cleaned of all dirt and debris prior to application of these TRI-BUILT
membranes.
Tri-Built Sand-R SA Shingle Underlayment applied to:
➢ Plywood;
➢ ASTM D41 primed plywood.
Note: While not required over plywood,Allied Building Products Corp. recommends priming the deck if the
final roof cover is not slated for installation within 24 hours.
Note: Allied Building Products Corp. requires tongue-and-groove board decking be covered with plywood
or OSB prior to installation of the self-adhering underlayment.
5.5.2 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI 07320
does not address wind uplift resistance of all underlayment systems beneath foam-on tile
systems, where the underlayment forms part of the load-path. The following wind uplift
limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are
used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind
load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of
design wind pressures.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111
Certificate of Authorization#9503 FL16048-R1
Revision 1: 08/27/2013
Page 3 of 6
QOTImNITY(ERD
5.5.2.1 Maximum Design Pressure = -315 Dsf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Tri-Built Tile and Metal HT Underlayment.
5.5.2.2 All other direct-deck, adhered TRI-BUILT underlayment systems beneath foam-on tile systems
carry a Maximum Design Pressure of -45 psf.
5.5.3 Bond-to-Insulation:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite
insulation; DensDeck DuraGuard; DensDeck Prime; or SECUROCK Gypsum-Fiber Roof
Board.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For
installations under foam-on tile systems, insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM
4470,Appendix K or TAS 114,Appendix J.
5.5.4 Bond to Mechanically Attached Base Laver:
➢ ASTM D226, Type I or II felt.
Note: For installations under mechanically attached prepared roof coverings, base layer shall be attached
per minimum codified requirements. For installations under foam-on tile systems, base layer shall be
attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120.
5.6 Exposure Limitations:
5.6.1 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment shall
not be left exposed for longer than 90-days after installation.
5.6.2 Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed for longer than 30-days
after installation
5.7 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following. Reference is made to the FRSA/TRI Technical Brief
titled "Florida High Wind Roof Tile Self-Adhered Underlayment Requirements as of
02/14/2011"for limitations for self-adhering underlayments used beneath tile roof systems.
TABLE 2:TILE SYSTEM OPTIONS PER FRSA/TRI 07320/8-05
System Underlay Section Reference Product(s)
Option
System One: 5 3.02E Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Mechanically Fastened Tile, No. 30/Self-Adhered Base Layer: ASTM D226,Type II
Unsealed or Sealed 6 3.02F Top Layer:Tri-Built Tile and Metal HT
Underlayment System Underlayment Underlayment
System Two: 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Mechanically Fastened Tile, No. 30/Self-Adhered Base Layer: ASTM D226,Type II
Sealed Underlayment 5 3.02E Underlayment Top Layer:Tri-Built Tile and Metal HT
System Underlayment
System Four"A": 4 3.021) Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
Adhesive-Set Tile, Unsealed No. 30/Self-Adhered Base Layer:ASTM D226,Type II
or Sealed Underlayment 5 3.02E Underlayment Top Layer:Tri-Built Tile and Metal HT
System Underlayment
3 3.02C Self-Adhered Underlayment Tri-Built Tile and Metal HT Underlayment
System Four"B":
Adhesive-Set Tlle,Sealed No. 30/Self-Adhered Base Layer:ASTM D226,Type II
Underlayment System 4 3.021) Underlayment Top Layer:Tri-Built Tile and Metal HT
Underlayment
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111
Certificate of Authorization#9503 FL16048-RI
Revision 1: 08/27/2013
Page 4 of 6
TRINIIY I ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with Allied Building Products
Corp. / TRI-BUILT published installation requirements subject to the Limitations set forth in
Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate (if applicable).
6.3 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT
Underlayment:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D1970
underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 For non-tile applications:
6.3.2.1 Back-nail selvage edge seams in accordance with the Allied Building Products Corp. / TRI-
BUILT Back-Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring-shank type with
a minimum 1-inch diameter metal disk or Simplex-type metal cap nail, at a minimum rate of
12"o.c. The head lap membrane is to cover the area being back-nailed.
6.3.2.2 All seal-lap seams (selvage laps)
must be firmly rolled with a
minimum 28 lb. hand roller to
ensure full contact and adhesion.
For Tri-Built Tile and Metal HT
Underlayment, align the edge of the `r
top sheet to the end of the glue
pattern (the sheet will overlap the
fabric).
Overlap Seam;Tri-Built Tile and Metal HT Underlayment
6.3.2.3 Install to ensure full contact with approved substrates. Allied Building Products Corp. / TRI-
BUILT require a minimum of 40-Ib weighted-roller or, on steep slopes, use of a stiff broom
with approximately 40-lbs of load applied for the field membrane. Hand rollers are
acceptable for rolling of patches, laps (min. 28 Ib roller) or small areas of the roof that are
not accessible to a large roller or broom.
6.3.3 For tile applications (Tri-Built Tile and Metal HT Underlayment only):
6.3.3.1 Reference is made to Section 6.3.2 herein in conjunction with FRSA/TRI 07320/8-05
Installation Manual, Fourth Edition, and Table 2 herein, using the instructions noted above as
a guideline.
6.4 Tri-Built Sand-R SA Shingle Underlayment:
6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 For non-tile applications:
6.4.2.1 While priming is optional, Allied Building Products Corp. recommends priming the deck if the
final roof cover is not slated for installation within 24 hours.
6.4.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel
back the first 3 ft of release film.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-Ri
Certificate of Authorization#9503 FL16048-R1
Revision 1: 08/27/2013
Page 5 of 6
TR1Nrry j ER®
6.4.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as
possible.
6.4.2.4 Once the entire length of membrane is in place, peel-off the release film diagonally while
holding the membrane tight. Firmly roll the membrane into place to achieve a bond.
6.4.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams
should be 6-inches and staggered not less than 2-ft from vertical seams in the course below.
All over-granule end-laps shall be sealed using either heat-welding or hot air welding
techniques.
6.4.2.6 When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing
in the overlap area at the top of the sheet at 12-inch o.c.
6.4.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper
and center sheet over valley or ridge. Drape and press sheet into-place, working from the
center of the valley or ridge in each direction. For valleys, apply the sheet starting at the
lowest point and work upward.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL, LLC - QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT-
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-111
Certificate of Authorization#9503 FL16048-R1
Revision 1: 08/27/2013
Page 6 of 6
i