Certification for Design Load Compliance
Project Name: S z y `� r<661 b 1W CE,
Project Address: D 1 T� �', L QT?' . 75Q'
Permit#: Occupancy Type: Construction Type: Wt). -WVC'
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
Residential Addition �t.,— KD-air- U$t W,�t 15\/ crzt m r M *L FA-Wr--`-!
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions:
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1.. DESIGN CODE: Florida V Code 2010 Edition with 20 V/Supplements using ASCE 7-10
2. Structure Designed as(check one): �I nclosed Partially Enclosed Open
3. Risk Category: _I II III IV f Exposure Category: B C V D
4. Design Wind Velocity _141; V' ASD LRFD End Zone Width: ft
r
5. Mean Roof Height C; ft Roof Pitch: :12 Parapet: &1 1A ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all,plan openings):
Zone 1:r Zone 2: �O - Zone 3: yZone 4: Zone 5: Garage:
7. Design Loads: Floor: J4& PSF Roof/Dead: / / PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? , Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? v-Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: /D PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTI ON STATEMENT:
IvuVwguy
I certify that, to the bemgknA�r odr�Pnd belief, the attached plans &specifications have been designed to
comply with the ap ��sa�t�cr��ditio6`f the building codes currently adopted and enforced by St. Lucie
County. I also ceey thj,�°k'Ae i jIe%ents'epicted on these plans provide adequate resistance to the design
forces specified: •
° N0.38521 e
m
TATE OF a Print lame Ce #&Co.Cert Auth.
s
°
°
0.
0.0 141-4
Sig ature, Date,and Se �°'�11161151% d� ��lCi ®il� �. �4®
MAY 2 6 2015 Company Name&Address
SLCCDV Form#020-12 Revised 3/15/12(JS)