Loading...
HomeMy WebLinkAboutMisc Letters PERMIT #:56-SF-1648485 STATE OF FLORIDA APPLICATION #:AP1190178 �* . DEPARTMENT OF HEALTH DATE PAID: ONSITE SEWAGE TREATMENT AND DISPOSAL, SYSTEM FEE PAID: CONSTRUCTION PERMIT RECEIPT #: we DOCUMENT #:PR976909 CONSTRUCTION TERMIT FOR: OSTDS Repair APPLICANT: Ernest Todd Johnson ...... . ......... . PROPERTY ADDRESS: 5309 Sunset Blvd Fort Pierce,FL 34982 LOT: 43/44 BLOCK: 52 SUBDIVISION: Indian River Estates PROPERTY ID #: 3402-608-0483-000-8 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S.., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF .SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO, MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT. BEING MADE NULL AND VOID. ISSUANCE OF. THIS PERMIT.. DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL VERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,000 ] GALLONS / GPD Septic CAPACITY A [ 0 ] GALLONS / GPD CAPACITY N [ 0 ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 .GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @j ]DOSES PER 24 HRS #Pumps [ ] D [ 300 ] SQUARE FEET SYSTEM R [ 0 ] SQUARE FEET SYSTEM A.TYPE SYSTEM: [ ] STANDARD [X] FILLED [ ] MOUND j :] I CONFIGURATION: [x] TRENCH j ] BED j ] N F LOCATION OF BENCHMARK: Orange spcYon rock.at SW corner of screen porch slab; i"below slab I ELEVATION OF PROPOSED SYSTEM SITE [ 2400][ INCHES FT ][ABOVE ' BELOW $ENCHMARKJ-REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 3.1.00 ][ INCHES ET ][ABOVE '$FLOW' BENCHMARK/REFERENCE POINT L D FILL REQUIRED': [11.00] INCHES EXCAVATION REQUIRED: [ ] INCHES The system is sized for 3 bedrooms.with a maximum occupancy of 6 persons(2 per bedroom),for a total.estimated flow 0 of 304 gpd. T The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance H with s.64E-6.013(3)(0,FRC.Required drainfield area based on rule 64E-6.015(6)(c)2. Install a new drainfieid to achieve Drainfield size requirement. E R SPECIFICATIONS BY: Brian J Ingram TITLE: f',S C t., L: APPROVED BY; TITLE: Environmental specialist I St.Lucie CHD Jacob K Kirchner DATE ISSUED: 05/28/2015 EXPIRATION DATE: 08/25/2415 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1190178 SE961641