Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAI]Lcookmenard@yahoo.com June 3, 2015 'x % Saint Lucie County Building Department Attn: Roof Permit Plan Review FILE COPy, 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 138 Vindale Ave,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 GA 5v Crimp FL.#11651.12 Code: FBC 2010; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 4/12 Required Design Pressure: Zone1:-38.2 Zone 2:-53.9 Zone3:-101.4 Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12"o.c., Fasteners: #9-15 x 1-%"woodzac w/24 C head%" minimum penetration &#9 X 1" pan head @ every slot. Underlayment: Interwrap, Inc. NOA# 13-0730.01,Titanium Psu-30,self-adhered,with minimum 3"horizontal laps&minimum 6"vertical laps. Place the first course of Titanium Psu-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru out Zone 1,4" o.c. perimeter& 6"o.c.field Zone 2, and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances,2010 Florida Building Code,and the Manufacturer's recommendations. Resp tfully Submitted, /A/ Peter B.Cook Cook&Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789