HomeMy WebLinkAboutEngineering Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design CA# 28173 June 2, 2015 RE: 8824 Champions Way, Port St. Lucie, FL 34986 The purpose of this letter is to address the match-up of the indoor air handling unit with the outdoor condensing unit for the split DX air conditioning system at the above address. The indoor air handling unit is an existing Lennox model CB29M-65-2P, rated at 5 tons, and the outdoor condensing unit which is being replaced for repair of the system is a Goodman model GSX140601 rated at 5 tons. This replacement condensing unit is an acceptable match-up for cooling capacity and inter-operability with the existing indoor air handling unit (with proper expansion device). The newer, more efficient condensing unit should provide at a minimum the previous system efficiency, if not exceed the rating as per section 403.6.2.3, exception to the FBC Energy Conservation Code. W�ctfu�I�N�u. d, 0 6 9 2 d ti e l is JSSy� a� PE;%UD AP �. le�h nica E ginQ�rz rincipaI ;r ��i rJ a.➢95ca�r: 315 South Th Street ♦ Fort Pierce,FL 34950 ♦ Phone 772-672-4636 ♦ Fax 772-672-4637 www.fp-eng.com Z:IR Pierce Engineering\15 ProjecrslHVAC Lepers\15972411 All Tech Ref-Spears ResidenceTmespondenceUiVAC App—Ldoc Page I of 1