HomeMy WebLinkAboutProduct Approval Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, INC.
24 Ga. Gulf Seam 18" Wide Roof Panel over 15/32"Plywood
Florida Product Approval # 11651.11111
Florida Building Code 2010
Per Rule 9N-3
Method:i—D
Category:Roofing
Subcategory:Metal Roofing
Compliance Method:9N-3.005(1)(d)
NON HVHZ
Product Manufacturer:
GULF COAST SUPPLY&MANUFACTURING,I.I.C.
4020 S.W.449` Street
Horseshoe Beach,Florida 32648
Eneineer Evaluator:
Terrence E.Wolfe, P.E.#44923
Florida Evaluation ANE ID:1920
Validator:
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents:
Evaluation Report Pages 1—4
',��1Sf11)!l1JJJ!
♦�1* '��,C E•��p�sfi
• - z
STATE 4F ;,q
�OfFimift
� ,������•N AL;i 1 iV j1�
!11
FL#11651.11 R1 February 22. 2012
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Design Uplift Pressures:
Table"A"
Maximum Total Uplift Design Pressure: 69.25 psf 108.5 psf
Clip Spacing: 24"O.G 12"O.G
#Fasteners per dip: 2 2
`Design Pressure includes a Safety Factor=2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010,Section 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010,as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ UL 580-06-Test for Uplift Resistance of Roof Assemblies
■ UL 1897-04-Uplift Test for Roof Covering Systems
Reference Data: 1. UL 580-94/1897-98 Uplift Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.117-0102T-05,117-0284T-09
2. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Test Standard Equivalency: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
1,��111S1i'ttll�ll
Z
.40
STATE OF ,'a
.0F w'`
+ AN ORI
'
swop, ++4 • ; ,*
026 ���i OohA1- ;� �
t it s
FL#11651.11 Rl February 22, 2012
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Sections
1507.4.2 and in accordance with Manufacturers recommendations.
Installation: Install per manufacturer's recommended details.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1507.4.5.
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on.the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
1,,*3S7i1!llr�,!!
NO.444�
1
STATE OF
s0267JR ' 4NAL1�
111j
FI.#11651.11 RI
February 22, 2012
Force Engineering&Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2010,Sections 1504.3.2.
Product Description: Gulf Seam Roof Panel, 1 %" Snap Lock, 24 Ga. Steel, 18" Wide, Roof Panel
restrained with steel fixed clips into 15/32" Plywood decking. Non-Structural
Application.
Panel Material/Standards: Material: Minimum 24 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to
Florida Building Code 2010 Section 1507.4.3. Paint finish optional.
Yield Strength: Min.50.0 ksi
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2010,Section 1507.4.3
Panel Dimension(s): Thickness: 0.023"Minimum
Width: 18"Maximum
Rib Height: 1-3/4"
Panel Seam: Snap Lock
Panel Rollformer: New Tech Machinery Roliformer
Roof Panel Clip: Type: Fixed,18 Ga.,3%"long
Corrosion Resistance: Per Florida Building Code 2010 Section 1506.7
Roof Clip Fastener. (2)#10-12 Pancake Type A
'/<"minimum penetration through plywood
Corrosion Resistance:Per Florida Building Code 2010,Section 1506.6,1507.4.4
Substrate Description: 15/32"thick,APA Rated plywood. Plywood supports at maximum 24"O.C.
Design of plywood and plywood suppbrts are outside the scope of this
evaluation. Must be designed in accordance w/Florida Building Code 2010.
,,,��lflilJllll��f
No.�
y
STATE OF
ORI
smu� �,s.�ON Al.
���.11111i10
FL#11651.11 RI
February 22. 2012
MIAMFDADE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
F 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy
Interwrap,Inc.
32923 Mission Way
Mission,BC,Canada V2V-6E4
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid. after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify,or suspend the use of such product or material within their jurisdiction. RER reserves the.right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Titanium@ UDL-30/Titaniumg PSU-30,Titanium®UDL-25 PLUS/Titanium®DSII-30,
and UDL-MD (2 ply)/Titanium®PSU-30 Underlayment System
LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMII+tATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#11-0815.05 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
IAM4DADE CONOA No.: 13-0730.01
�lRIM
.... MUNTY Expiration Date: 01/26/17
Approval Date: 11/14/13
Page 1 of 7
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Category: Underlayment
Material: Polypropylene
TRADE NAMES OF PRODUCTS MANUFACTURED BY APPLICANT
TABLE 1
Product Dimensions Test Product
Specification Description
Titanium®UDL-25 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with one
PLUS Type I&H side coated with UV protected and slip resistant
polymer stabilized polypropylene on both sides.
Manufacturing
Location#1
UDL-N D (2Ply system) 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with a
Type I&H chemical slip resistant and UV protected coating on
Manufacturing both sides.
Location#2
Titanium®UD1-30 48"x 250' rolls ASTM D226 Woven synthetic polymer underlayment with two -
Type I& H sides coated with UV protected and slip resistant
Manufacturing polymer stabilized polypropylene on both sides.
Location#1
Titanium®PSU-30 36"x 72' rolls TAS 103 Unreinforced polymer modified bitumen material
adhered to the underside of a polymer-coated,
Manufacturing synthetic woven sheet. The underside is backed
Location #3 with a release film.
MANUFACTURING LOCATIONS:
1. ML 1
2. MM3
3. ML4
MIAM!•)ADE CONOA No.: 13-0730.01
UNTY
Expiration Date: 01/26/17
Approval Date: 11/14/13
Page 2 of 7
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Intertek Testing Services 43031783 TAS 104 02/19/03
3119607COQ-003B ICC-ES AC48 02/20/08
3124826-01 ASTM E108 02/19/08
3124826NM-007 ASTM El 08 02/25/08
311801000Q-003 ASTM D226 '02/20/08
3130639COQ-002A ASTM D226 02/20/08
3146738COQ-003A ASTM D226 04/22/08
3146738COQ-003B ASTM D 1876/TAS 117 03/28/08
Trinity ERD 135520.06.11 TAS 103 /TAS 104 06/15/11
I38010.08.11 ASTM D226 08/11/11
I35520.08.11 ASTM D2523 /D1781 08/17/11
I35520.08.11-1 TAS 114 -08/12/11
135520.06.11 TAS 103 /TAS 104 06/15/11
I44970.07.13 ASTM D226/D1781 /TAS 07/18/13
114
NOA No.: 13-0730.01
MIAMWADE COUNTY
APPROVEDI Expiration Date: 01/26/17
Approval Date: 11/14/13
Page 3 of 7