HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com June 2, 2015 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at, 4475 N. Old Dixie Hwy, Saint Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 Ga 5v Crimp FL. #11651.12 Code: FBC 2010;Section R 905.10 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 4/12 Required Design Pressure: Zone1:-40.7 Zone 2: -61.8 Zone3:-107.9 Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12" o.c., Fasteners: #9-15 x 1-%"woodzac w/24 C head'/"minimum penetration &#9 X 1" pan head @ every slot. Underlayment: Interwrap, Inc. NOA# 13-0730.01,Titanium Psu-30,self-adhered,with minimum 3" horizontal laps & minimum 6"vertical laps. Place the first course of Titanium Psu-30 parallel to the eave and field, using a heavy pressure roller under safe conditions to further secure the membrane. Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c. thru out Zone 1,4" o.c. perimeter& 6"o.c.field Zone 2,and 4" o.c.thru out Zone3 The above approved, as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789