HomeMy WebLinkAboutMisc Letters 1918 Corporate Drive
r r1 z FC IGHT
Boynton Beach,FL 33426
WIN D O W S Ph.561-922-6747
Fax.561-292-3562
Property Information JF Building Information
Owner: Jennifer Cruz or Juan Cruz-Robles Wind Zone: 160 MPH.
Address: 4837 Sears Street Exposure Category: C
Ft Pierce,FL 34981 Minimum Building Dimension: 37 ft.
Mean Roof Height: 11 ft.
W Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device j Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) L Pressure(psf) Pressure(psf)
I End 73 49 7 31.5 -40.9
2 Int 35 49 7 33.1 -35.9
----------
3 Int 73 37 7 32.1 -34.9
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Florida Building Code 2010 ed.
Page 1 of I
.. —
®.;. . _`.
a
10
r
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
OPENING (Location) IS THIS A PRODUCT ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION WINDOW SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N
SIZE REQ Y/N/NA
1 End W 78"I.amiIG 14-0128.06 55 55 31.5 40.9 74X63 73x49 N N
2 Int W 78"LamiIG 13-1007.10 55 55 33.1 35.9 53x77 35x49 N N
3 Int w 7/8"Lam1IG 14-0128.06 55 55 32.1 34.9 74X63 73x37 N N