Loading...
HomeMy WebLinkAboutMisc Letters 1918 Corporate Drive r r1 z FC IGHT Boynton Beach,FL 33426 WIN D O W S Ph.561-922-6747 Fax.561-292-3562 Property Information JF Building Information Owner: Jennifer Cruz or Juan Cruz-Robles Wind Zone: 160 MPH. Address: 4837 Sears Street Exposure Category: C Ft Pierce,FL 34981 Minimum Building Dimension: 37 ft. Mean Roof Height: 11 ft. W Risk Category: II Design Pressure Calculations Opening Location Device Device Device j Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) L Pressure(psf) Pressure(psf) I End 73 49 7 31.5 -40.9 2 Int 35 49 7 33.1 -35.9 ---------- 3 Int 73 37 7 32.1 -34.9 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.Florida Building Code 2010 ed. Page 1 of I .. — ®.;. . _`. a 10 r A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE OPENING (Location) IS THIS A PRODUCT ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION WINDOW SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N SIZE REQ Y/N/NA 1 End W 78"I.amiIG 14-0128.06 55 55 31.5 40.9 74X63 73x49 N N 2 Int W 78"LamiIG 13-1007.10 55 55 33.1 35.9 53x77 35x49 N N 3 Int w 7/8"Lam1IG 14-0128.06 55 55 32.1 34.9 74X63 73x37 N N