Loading...
HomeMy WebLinkAboutEnergy Calculation Form & Manual J's _Y s 1 Florida Ener Effic�enc Code For:Buildin Con tructiq 9Y Y r Ener puge Summit® Fla/C.om:2010, Effective Date March 15;x2012 Form 50&'201 = Total Building PerformanceSMethod for-,Commercial Buildings . .,_..........,.,. .....,. .na. :,..........>_ . .P.. ..,,. ., n..�. .-e.,...... w.. .............. .,....,..... ., ,..,.. ...F.. s,.a.. ,«, -...-..,., _. .... .. .,._...,.. _..... 1.,.<., .. ,. .. n.. .,,.s. ..cF_4 PROJECT SUMMARY Short Desc: HOORAGS Description: HOORAGS Owner: Addressl: 111 COMMERCIAL CIRCLE City: FT.PIERCE Address2: State: FL Zip: 0 Type: Warehouse Class: New Finished building Jurisdiction: FORT PIERCE, ST LUCIE COUNTY,FL(661100) Conditioned Area: 1716 SF Conditioned&UnConditioned Area: 1716 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 4.7 If different,write in: EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012- 6/10/2015 Page 1 of 7 Compliance Summary Component Design Criteria Result Gross Energy Cost(in$) 839.0 1,017.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry WATER HEATING SYSTEMS No Entry PIPING SYSTEMS No Entry Met all required compliance from Check List? Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- --An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 2 of 7 S CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code �y Prepared By/i/, Building Official: Date: (�G��h Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify(*)that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer Reg No: ��lC� f Plumbing Designer: Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 3 of 7 Project:HOORAGS Title:HOORAGS Type:Warehouse (WEA File: FL ST_LUCIE_CO_INTL.tm3) Building End Uses 1) Proposed 2) Baseline Total 52.70 79.60 $839 $1,271 ELECTRICITY(MBtu/kWh 52.70 79.60 /$) 15442 23315 $839 $1,271 AREA LIGHTS 13.10 14.30 3828 4204 $208 $229 MISC EQUIPMT 3.40 3.40 1006 1006 $55 $55 PUMPS & MISC 0.10 0.10 23 18 $1 $1 SPACE COOL 15.80 28.20 4618 8258 $251 $450 SPACE HEAT 3.60 4.30 1061 1255 $58 $68 VENT FANS 16.70 29.30 4906 8574 $266 $467 Credits Applied: None PASSES Passing Criteria= 1017 Design(including any credits)=839 Passing requires Proposed Building cost to be at most 80% of Baseline cost. This Proposed Building is at 66% EnergyGauge Summit@ Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 4 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No.of Units (W) (W) (Sgft or ft) None Project:HOORAGS Title:HOORAGS Type:Warehouse (WEA File:FL ST LUCIE CO INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance Prozo1Sp1 3 Storage&Warehouse-Bulky 1,716 1 1 PASSES Active Storage PASSES Project: HOORAGS Title: HOORAGS Type:Warehouse (WEA File:FL ST_LUCIE_CO_INTL.tm3) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System<65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 56000 14.00 12.23 8.00 PASSES Split System<65000 Btu/h Cooling Capacity Heating System Electric Furnace 34000 1.00 1.00 PASSES Air Handling System Air Handler(Supply)- 2000 0.80 0.82 PASSES -Supply Constant Volume PASSES EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 5 of 7 2 Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None Water Heater Compliance Description Type Category Design Min Design Max Comp Eff Eff Loss Loss liance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] .SF.F] None EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 6 of 7 I Project:HOORAGS Title:HOORAGS Type:Warehouse (WEA File: FL ST LUC1E CO_1NTL.tm3) Other Required Compliance Category Section Requirement(write N/A in box if not applicable) Check Report 506.4.2 Input Report Print-Out from EnergyGauge F1aCom attached Operations Manual 303.3.1, Operations manual provided to owner 503.2.9.3, 505.7.4.2 Windows&Doors 502.3.2 Glazed swinging entrance&revolving doors:max. 1.0 cfin/ftz;all other products: 0.3 cfin/ftz Joints/Cracks 502.3.3 To be caulked,gasketed,weather-stripped or otherwise sealed E Dropped Ceiling Cavity 502.3 Vented: seal&insulated ceiling.Unvented seal&insulate roof& side walls HVAC Efficiency 503.2.3 Minimum efficiencies: Tables 503.2.3(1)-(8) ❑ HVAC Controls 503.2.4 Zone controls prevent reheat(exceptions); separate thermostatic El control per zone; Ventilation 503.2.5 Outdoor air supply&exhaust ducts shall have dampers that ❑ automatically shut when systems or spaces served are not in use. Exhaust air energy recovery required for cooling systems (Exceptions). ADS 503.2.7.5 Duct sizing and Design have been performed HVAC Ducts 503.2.7 Air ducts,fittings,mechanical equipment&plenum chambers shall be mechanically attached, sealed,insulated&installed per Table 503.2.7.2.Fan power limitations. Balancing 503.2.9.1 HVAC distribution system(s)tested&balanced.Report in construction documents. Piping Insulation 503.2.8 HAC and service hot water.In accordance with Table 503.2.8. El Water Heaters 504 Performance requirements in accordance with Table 504.2.Heat trap required. Swimming Pools 504.7 Vapor-retardant or liquid cover or other means proven to reduce heat loss on heated pools;Time switch(exceptions);readily accessible on/off switch. Motors 505.7.5 Motor efficiency criteria have been met ❑ Lighting Controls 505.2, 502.3 Automatic control required for interior lighting in buildings>5,000 s.f.; Space control;Exterior photo sensor;Tandom wiring with 1 or 3 linear fluorescent lamps>30W EnergyGauge Summit®Fla/Com-2010. Section 506.4 Compliant Software. Effective Date: March 15, 2012 6/10/2015 Page 7 of 7 EnergyGauge Summit®v5.00 INPUT DATA REPORT Project Information Project Name: HOORAGS Orientation: North Project Title: HOORAGS Building Type: Warehouse Address: 111 CON 4ERCIAL CIRCLE Building Classification: New Finished building State: FL No.of Stories: ] Zip: 0 GrossArea: 1716 SF Owner: r_ Zones No Acronym Description Type Area Multiplier Total Area [sf] [sf] 1 PrOZo 1 Zone 1 CONDITIONED 1716.0 1 1716.0 ❑ Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [cf] 6/10/2015 EnergyGauge Summit®v5.00 1 In Zone: PrOZol 1 PrOZo 1 So 1 Zo0Sp 1 Storage&Warehouse- 26.00 66.00 21.00 1 1716.0 36036.0 El Bulky Active Storage Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts r� In Zone: PrOZol In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 50 25 1250 Manual On/Off 1 ❑ Walls No Description Type Width H(Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr.sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 1 PrOZolWal Stucco, 8"Block, 26.00 21.00 1 546.0 East 0.1110 7.751 41.32 9.0 ❑ R-4.1, Gyp.Brd. 2 PrOZolWa2 Stucco, 8"Block, 66.00 21.00 1 1386.0 South 0.1110 7.751 41.32 9.0 ❑ R-4.1, Gyp.Brd. 3 Pr0Zo 1 Wa3 Stucco, 8"Block, 26.00 21.00 1 546.0 West 0.1110 7.751 41.32 9.0 ❑ R-4.1, Gyp.Brd. Windows No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sfJ In Zone: In Wall: 6/10/2015 EnergyGange Summit®v5.00 2 Doors No Description Type Shaded? Width H(Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf.F] [Ib/cf] [Btu/sf.F] [h.sf.FBtu] In Zone: PrOZol In Wall: PrOZo1Wa2 1 PrOZo1Wa2Dr1 Polystyrene core No 11.00 12.00 2 132.0 0.4982 0.00 0.00 2.01 ❑ (18 ga steel) 1 Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr.SE F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] In Zone: PrOZol 1 PrOZo1Rf1 Built-up Gravel/2" 66.00 26.00 1 1716.0 0.00 0.1486 0.98 12.59 6.7 ❑ ISO/Mtl Deck Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multinlier Area Total Area [Btu/hr sf F] [ft] Vt] [Sf] [Sf] In Zone: In Roof: El Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZo1F11 1 ft. soil, concrete 66.00 26.00 1 1716.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad 6/10/2015 EnergyGauge Summit®v5.00 3 Systems PrOSyl System 1 Constant Volume Air Cooled Split No.Of Units 1 System<65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System 56000.00 14.00 8.00 ❑ 2 Heating System 34000.00 1.00 3 Air Handling System-Supply 2000.00 0.80 1 Plant Equipment Category Size Inst.No Ef .. IPLV Li Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss Ext-Lighting Description Category No.of Watts per Area/Len/No.of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] El Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [Btu-in/h.sf.F] [in] [in] 6/10/2015 EnergyGauge Summit®v5.00 4 Fenestration Used Name Glass'Type No.of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ` Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.FBtu] IN [Btu/h.ft.F] pb/cf] [Btu/Ib.F] 187 MatII87 UYP OR FLAS No 0.4533 0.0417 0.0920 50.00 0.2000 Li BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in.Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW ) 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 11 Matl11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAGI/21N Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtu] 1033 Polystyrene core(18 ga steel) 1 No Yes 0.50 2.0 ❑ 6/10/2015 EnergyGauge Summit®v5.00 5 Layer Material Material Thickness Framing No. [ft] Factor 1 284 Polystyrene core(18 ga steel) 1 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1045 Built-up Gravel/2"ISO/Mtl Deck No No 0.15 0.98 12.59 6.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 248 ROOF GRAVEL OR SLAGl/21N 0.0417 0.000 ❑ 2 11 2 in. Insulation 0.1670 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in.Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1060 Stucco, 8"Block,R-4.1, Gyp.Brd. No No 0.11 7.75 41.32 9.0 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 123 CONC BLOCK MW,81N,HOLLOW 0.6667 0.000 ❑ 2 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ 3 267 0.75" stucco 0.0625 0.000 ❑ 4 11 2 in. Insulation 0.1670 0.000 ❑ 6/10/2015 EnergyGauge Summit®v5.00 6 R/ht-Suite® Universal 2015 Short Form Joe Wrightsoft® � Date: Jun 10,2015 Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL34946 Phone:772-466.6799 Fax 772-466.6796 Email:QUICKCALCS@AOL.COM Project Information For. HOORAGS 111 COMMERCIAL CIRCLE, FT. PIERCE, FL 34951 Htg Clg Htg Clg Outside db (°F) 42 90 Inside db (°F) 70 75 Outside RH (%) - 60 Inside RH M - 50 Outside wb (°F) - 78 Inside wb (°F) - 63 Daily range (°F) - 15 Design TD (°F) 28 15 Moisture diff. (gr/lb) - 61 Heating Equipment Cooling Equipment Make Make Carrier Model ModGIA14NA06000GAA/FBC4NP060L00AEE Type Elec strip Type Split AC Efficiency 100 EFF COP/EER/SEER 14.0 Heating Input 5.1 kW Sensible Cooling 39.9 MBtuh Heating Output 17.4 MBtuh Latent Cooling 17.1 MBtuh Humidifier 6.1 gpd Total Cooling 57.0 MBtuh Leaving Air Temp 78.4 OF Leaving Air Temp 55.0 OF Actual Heating Fan 1900 cfm Actual Cooling Fan 1900 cfm Equipment Location Entire House System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME Area Heat Sensible Latent Htg Clg Time ft2 Loss Gain Gain cfm cfm BUILDING 1690 29041 49767 7266 1900 1900 Jul 1500 LDT Entire House 1690 29041 49767 7266 1900 1900 Jul 1500 LDT 2015Jun-10 14:49:38 wrightsoft' RightSuite®Universal 2015 15.0.02 RSU08101 Page 1 C:\Users\Quid(Calcs\Documents\HOORAGS.rup Calc=CLTD Front Door faces N Riga-Suite® Universal 2015 Load Summary Joe Wrightsoft� By: Jun 10,zoos BUILDING QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,FL34946 Phone:772-466-6799 Fax 772A666796 Email:QUICKC4LCS@AOL.COM Project • • For. HOORAGS 111 COMMERCIAL CIRCLE, FT. PIERCE, FL 34951 1. DESIGN CONDITIONS at Jul 1500 LDT Peak load at Jul 1500 LDT Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 60 % MoistDiff: 61.5 gr/Ib Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 0 - 3. TRANSMISSION GAINS Sensible 24874 Walls: 2718 - - Glass: 0 - - Doors: 306 - - Partitions: 0 - - Floors: 0 - - Ceilings: 21850 - - 4. INTERNAL HEAT GAIN Sensible Latent 6730 1000 Occupants: 1250 1000 - - Lights: 5480 - - - Motors: 0 - - - Appliances: 0 0 - - 5. INFILTRATION: Outside air cfm: 75 1199 3133 6. SUBTOTAL: Space load Sensible Latent 32803 4133 Envelope 32803 4133 - - Less external 0 - - - Redistribution 0 0 - - 7. SUPPLYDUCT 9689 - 8. SUBTOTAL: Space load+ supply duct 42493 - Actual cfm: 1900 at supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 75 1199 3133 10. RETURNAIRLOAD: Lighting+ plenum (net) 0 - 11. RETURN DUCT 6075 - 12. TOTAL LOADS ON EQUIPMENT 49767 7266 HEATING LOAD 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 15348 Wal Is: 5148 - Glass: 0 - Doors: 635 - Partitions: 0 - Floors: 1966 - Ceilings: 7600 - 15. INFILTRATION: Outside air cfm: 192 5911 16. SUBTOTAL: Space load 21260 Envelope 21260 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 4368 18. VENTILATION: Make-up air cfm: 0 0 19. HUMIDIFICATION 2324 Piping 0 20. RETURN DUCT 1089 21. TOTAL HEATING LOAD ON EQUIPMENT 29041 2015-Jun-10 14:49:38 wrilghtSOW RightSuite®Universal 2015 15.0.02 RSU08101 Page 1 C:\Users\Quick Calcs\Documents\HOORAGS.rup Calc=CLTD Front boor faces N • ADJACENT BUILDING -A 1A01A I lax 113 'a - -100 a00 2op ROD CTO � -no C;WA C;FIA QL4y,a4 BUILDING Job#: QUICK CALCS, INC. Scale: 1 : 112 Performed for: Page I HOORAGS 317 ST LUCIE LN. Right-SulteO Universal 2015 III COMMERCIAL CIRCLE FT PIERCE, R-34946 15.0.02 RSU08101 FT.PIERCE, FL 34951 Phone: 772466-6799 Fax:772-466-6796 2015-Jun-1015:10:58 QUI CKCALCS@AOL.COM ...uick CalcMDocurnentsHOORAGS...