Loading...
HomeMy WebLinkAboutEngineering f PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com June 17, 2015 FIL E, 1 Re: Lanza Shutter Installation 9650 S. Ocean Dr. (#1105) Jensen Beach,FL 34957 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2010 for the installation of accordion shutters at the above referenced address. Wind speed: Vwt: 165 mph, Vasa: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96"Maximum Height Shutter Location: Covered Porch(See Attached Sketch) Required Design Pressure: +29.3 /-39.2 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above"Required Design Pressure". Accordion Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2010. Accordion Shutters shall be FL# 389.1. Thank you for your attention to this matter. Submitte by: PAUL CH INC. Paul Weld i,P.E. Reg. No 29945 i J 00 0� . q?, 00 dA ..G3 r: s ` At1L WELCH.INC. . -- --- - --_-� .- - - - ---- ---- -- - , - MECH-ELECT-CIVIL ENG. Lanza Shutter Installation 1984 SiLTNIORE ST.#114 PORT SAINT,LUCIE,FL 3,4984 9650 S. Ocean Dr. (41105) PAM WELCH R.E. Jensen Beach,FL 3495 FLA REG NC}.29945 , JUN 1 '� 2015