FL # FL389-R5
Application Type Revision
Code Version 2010
iSOApplication Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
http://www.floridabuilding.org/pr./pr_app_dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx53MwsXdCOtOX3bENFONI QQc%3d 5/9/2012
Fnne� nf4
\nr�b�E�ui�l� 9
«� {�o�� ��o]�x� _ �=_
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received `
Florida Engineer orArchitect Name who developed Walter A.. Ti}lM, Jr. P.E.
the Evaluation Report
Florida License PE-44167
[yua)|tv Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2013
Validated By John Henry KennprnannJr.
�j Va|idetionCheck!iyt - HardcopyReceived
Certificate ofIndependence FL389 R5 COI ASSA certification of indevendence.,drwq 11-192.p
Referenced Standard and Year (of Standard) Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 3O1, 2O2, 2O3 1994
Equivalence ofProduct Standards '
Certified By ' Florida Licensed Professional Engineer orArchitect
Sections from the Code
Product Approval Method Method 1Option D
http://www.floridabuilding.org/pr/pr�_app_dtl.aspx?param=wGEVXQwtDqvYYHH2vJvx53MwsXdCOtOX3bENFONIQQc�/�3d 5/9/2012
.
lli`pCode Online �nwe3mf4
u� - -�-
Date Submitted 12/21/2011
Date Validated 12/21/2011
Date Pending FBCApprova| 01/31/2012
Date Approved 04/03/2013
Summary of Products
FL # Model,-Number or Name IlDescription
389.1 Bertha HV Accordion Shutter - Extrud d aluminum interlocking blades retained by tracks
Blade 3 - (Non-HVHZ) - Drwg 11- (top and bottom) for storm protection
1190
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL389 RS II drwq 11-190 ASSA.vd
Approved for use outside HVHZ; Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
other: Large Missile Level "D". Max span is 13'-0" for 40 FL389 R5 AE groduct evaluation drwq 11-190.gdf
p.s.f. ASD negative load the HV3 blade w/o window blade, Created by Independent Third Party: Yes
5'-6" for 110 p.s.f ASD load for'HV3 blade w/o window blade
and 9'-6" for 62 p.s.f for HV3 blade w/ window blade
working in unison and 84" for 72 p.s.f. ASD load for HV3
blade w/o window blade installed into metal studs. See sheet
number 5 of installation drawings for other spans and
389.2 Bertha HV Accordion Shutter-Blade Extrud d aluminum interlocking blades retained by tracks
I I Only- (Non-HVHZ)- Drwg 11-192 (top and bottaT) for storm protection
Limits of Use Installation Instructions
Approved for use outside HVHZ: Yes Verified By: American Test Lab of South Florida Inc.'
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Large missile level "D". Max. Span is 16'-0" for 30. FL389 R5 AE ASSA Productevaluationreportdrwqlll92.p
p.s.f negative ASD load depending on centermates and Created by Independent Third Party: Yes
locking rod configuration for the HVI blade, 8'-0" for +64, -
72 p.s.f. load for HV blade for Keystone mountings 7'-0" for
+75, -75 p.s.f. for metals stud mountings and 8'-0" for 110
p.s.f. for HV1 and HV1A working in unison. See sheets 7, 11
and 20 respectively of installation drawings for other spans
'
dt l 5/9/2012
Ploncla milding cocte Utiline Page 4 of 4
land pressures.
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO- (Non-HVHZ)- Drwg 11-194 1(tap and bottom) for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL389 R5 II ASSA QRWG 11-194.i)df
Approved for use outside HVHZ: Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
other: Large missile. Max. 16'-0" span at 30 p.s.f ASD load FL389 R5 AE ASSA Product evaluation report drwq 11-
11for Blade I and 18'-0" for Blade 2. See schedules on sheet 194.j?d
12, 25 and 28 respectively Created by Independent Third Party: Yes
Back Next
Contact Us :: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cogyright 2007-2010 State of Florida. :: Privacy Statement :- Accessibility Statement :: Refund Statement
Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions regarding DBPR's ADA web accessibility, please
contact our Web Master at webmasterOdbDr.state.ft.us.
Product Approval Accepts:
jv
http://www.floridabuilding.org/pr/pr�_app_dtl.aspx?param=wGEVXQwtDqvYYHH2vJvx53MwsXdCOtOX3bENFONIQQc%3d 5/9/2012