Loading...
HomeMy WebLinkAboutProduct Evaluation Report EVALUATION REPORT OF METAL,SALES MANUFACTURING CORPORATION '26 GA.5V-CRIMP PANEL' FLORIDA PRODUCT APPROVAL, FL 16611.1 ROOFING METAL ROOFING Prepared.For: Metal Sales Manufacturing Corporation 545 South 3rd Street,Suite 200 Louisville,KY 40202 Telephone: (502)8554300 Fax: (502)8554290 Prepared By: Bala Sockalingan,Ph.D.,P.E. Florida Professional Engineer#62.240 1216 N Lansing Ave.,Suite C Tulsa,€1K 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(3 Pages.including cover) - Installation Details(1 Page) - ���� $4?Gf{A} ♦y�f *�• H4 62240 • Report Nm. 01934-1 Date: 10.11.13 Oma: �rAre OF •, �tz %m j4• mit tS'j •••...._• �, e o L �� FL 16611.1 C1934-1 10.11.13 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: SV-Crimp Panel Description: 24"wide coverage with(5) 1/2"high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792)or painted steel(ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood at max span of 24" for new and existing constructions. Designed and installed as per FBC 2010. Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c. in the plywood field and edges Underlayment: Minimum underlayment as per FBC 2010 Section 1507.4.5 Slope: 1/2:12 or greater in accordance with FBC 2010 Section 1507.4.2. For roof slope less than 3:12,lap sealant must be used in the panel sidelap. Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c. (Factor of Safety=-2) 172.5 psf @ fastener spacing of 6" o.c. Fastener Pattern: Type: #9-16 or ##10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8" and'installed as per Metal Sales.current installation procedure. At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems'. Code Compliance: The product described herein has demonstrated compliance with.FBC 2010 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2010 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2010 Section 1505 and current FL 1661.1.1 • C1934-1 10.11.13 Page 3 of 3 approved roofing materials directory or ASTM E 108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580& 1897 Test Reports PRI Construction Materials Technologies MSMC-017-02-01,Reporting Date 9/20/13 V!: tlECIQI)BYi PANEL OVEL'— :as, ove os. Rot SV—CRIMP 10/a/13FASTENER AT PANEL FLAT SEE DETAIL 2 / DETAIL 1 REQUIRED FOR PANEL 3 ENDS ONLY. u 8d x'2,5" LONG RING SHANK NAIL PANEL FASTENER PER ALLOWABLE OR #8 x 2" LONG WOOD SCREWS OR TABLE ON THIS SHEET. UNDERLAYMENT SHALL BE INSTALLED SPACED 0 6" O.C. IN THE FIELD & AS PER MANUFACTURER'S INSTALLATION AT PLYWOOD EDGES GUIDELINES °z TRUSS AT MAX. 2R4A OEC.JOIST/ D N TYPICAL PANEL INSTALLATION X—SECTION o #9-16 OR #10-14.WOODSCREWS DESIGN UPLIFT PRESSURE n � WITH SELF SEALING WASHER AT o MAXIMUM SPACING OF 36" O.C. FASTENER PRESSURE � o (IN) (PSF) SPACING i �N 5 10 5V—CRIMP 36 _ 30.0 0o MIN 26 GA. 20 o 6 172.5 Ln W � 1 ` GENERAL NOTES: Z 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE a FLORIDA BUILDING CODE (FBC). n a UNDERLAYMENT 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.019 . EFFECTIVE COVERING VOSB 7/16" THICK (MIN.) OR DETAIL 1 PLYWOOD 15/32 THICK (MIN.) WIDTH OF PANEL = 24 v 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. � E 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS #9-16 OR #10-14 WOODSCREWS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS WITH SELF SEALING WASHER AT ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING. MAXIMUM SPACING OF 36" O,C, 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN.THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 5V-CRIMP 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS MIN 26 GA. REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. A o � d a 4'3 U UNDERLAYMENT DETAIL 2 OSB 7THICK (MIN.) OR 1934-1 PLYWOODOD 1 15/32 THICK (MIN.) SHEEP x0. 1 � 1