Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3 tom; s w-tom. 1=i0rt a Npmrl%Ii tff BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ; FBC Staff i BCIS Site Map Links i Search Busines � *USER: PpProfessiknal °d°`t royal Publicc User Regulation Product Approval Menu>Product or Aoolication Search>Application List>Application Detail FL# FL15037-RO yioj�om;L / b Z�� Application Type New Code Version 2010 Application Status Approved FILE COPY Comments Archived I Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,01-143517 (419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .. Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King,P.E. G Validation Checklist- Hardcopy Received Certificate of Independence FL15037 RO COI Certificate of Indeoendence.odf Referenced Standard and Year(of Standard) Standard Year AAMA/W D MA/CSA 101/I.S.2/A 440 2005 ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2002 ASTM E1996 2005 ASTM E1996 2006 ASTM E330 2002 SSTD12 1999 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15037 RO Eouiv of Standards.ndf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73 Fr2ZyiPg... 6/22/2015 Florida Building Code Online Page 2 of 3 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/10/2011 Date Validated 08/27/2012 Date Pending FBC Approval 09/05/2012 Date Approved 10/09/2012 Date Revised 01/26/2015 Summary of Products FL# Model,Number or Name Description 15037.1 a.Opaque Fiberglass Door 6'8"Impact"Opaque"Fiber-Classic","Smooth-Star"or "Classic-Craft"Single Fiberglass Door with or without "Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or XO; OXO)Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL15037 RO II Inst 15037.1.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15037.1 for Design Pressure Ratings,any FL15037 RO AE Evai 15037.1.0f additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. 15037.2 b.Opaque Fiberglass Door 6'8"Impact"Opaque"Fiber-Classic","Smooth-Star"or "Classic-Craft"Double Fiberglass Door with or without "Impact"Sidelites-Outswing/ Inswing (XX or OXXO) Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS037 RO II INST 15037.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant: Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:See Inst 15037.2 fo r Design Pressure Ratings,any FL15037 RO AE Eval 15037.2.0 additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15037.3 c.Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star"or "Classic-Craft"Single Fiberglass Door with or without "Impact"Sidelite or Sidelites-Outswing/ Inswing (X,OX or XO; OXO)Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL150 7 RO II INST 15Q37.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See Inst 15037.3 fo r Design Pressure Ratings,any FL15037 RO AE Evall 15037.3.pdf additional use limitations,installation instructions and Created by Independent Third Party:Yes product particulars. 15037.4 d.Opaque Fiberglass Door 8'0"Impact"Opaque"Fiber-Classic","Smooth-Star"or "Classic-Craft"Double Fiberglass Door with or without "Impact"Sidelites-Outswing/Inswing (XX or OXXO) Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL 15037 RO 11 INST 1.5037.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See Inst 15037.4 fo r Design Pressure Ratings,any FL15037 RO AE Evai 15037.4.pdf additional use limitations,installation instructions and Created by Independent Third Party: Yes product particulars. Back Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquS73 Fr2ZyiPg... 6/22/2015 I Florida Building Code Online Page 3 of 3 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ., M eCFec M s�K:tln L.F M z Y'32.tL`.ti" https://www.floridabuilding.org/pr/pr_app_dtI.aspx?param=wGEVXQwtDquS 73 Fr2ZyiPg... 6/22/2015 R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 Nothict Eil(thlation Repoa Report Alm: FL-1503 7.4 Date: June 13,2012 Product Category Sub Category Manufacturer Product Name twinging Therma Tru Corporation Opaque Fiberglass Double Door Exterior Exterior Door 118 Industrial Drive with and w/out Sldelites Doors Assemblies Edgerton,OH 43517 Inswing/Outswing Phone 419.298.1740 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F:Schmidt,P.E.for Therma Tru Corporation based on Rule Chapter No.9N-3,Method 1 D of the State of Florida Product Approval,Department of Business &Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing theproductor in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 2010 Florida Building Code(FBC)structural requirements excluding the "High Velocity Hurricane Zone"(HVHZ). 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering.The glazing meets missile level"D".The assembly excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.4 of the FBC. 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-15037.4 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FLA 5037.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by CTLA 980W SSTD 12-99 Certified Testing Laboratories Ramesh Patel,P.E. TEL 01460274 ASTM E1886/1996-05 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E. TEL 01460440A ASTM E1886-05/1996-06&ASTM E330-02 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E. TEL 06-0831-1 AAMA/WDMA/101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. Wendell W.Haney,P.E. ASTM El 886/1996-02 2. Miami Dade NOA Materials Testing 11-1118.03 DuPont Butacite PVB Interlayer 09-0127.13 Solutia Interlayers for Laminated Glass 3. Drawing No. Prepared by Signed&Sealed by No.FL-15037.4 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt, P.E. 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute,certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. r Lyndon F.Schmidt,P.E. FL PE No.43409 8/24/2012 PF 1690 Sheet 1 of 1 j . R WR W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry P:O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Facsimile 813.754.9989 Florida Board of Professional Engineers Certificate of Authorization No.9813 Product Evaluation Report Report No.: FL-5891.2 RI Date: May 1,2008 Product Category: Exterior Doors Product sub-category: Swinging Exterior•Door Assemblies Product Name: 3'0"x 6`8 "Smooth Star" Fiberglass Single Door Inswing/Outswing "Impact" Manufacturer. Therma Tru Corporation 118 Industrial Drive Edgerton,OH 43517 Phone 419.298.1740 Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Wendell W. Haney,P.E.(System ID#1993)for Therma Tru Corporation based on Rule Chapter No:9B- 72.070,Method 1 d of the State of Florida Product Approval,Department of Community Affairs- Florida Building Commission. RW Building Consultants and Wendell W.Haney,P.E.do not have nor will acquire.financial interest-in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product:has been evaluated for use in locations adhering to the Florida Building Code (2007 Edition) See-Drawing No.FL-5.891.2 prepared by R W Building Consultants,Inc.and signed and sealed by Wendell W.Haney,P.E.(FL#54158)for specific use parameters. Wendell V+T I n ,P.E. FL No.54158 May 1,2008 PF863 Sheet 1 of 3 �f Limitations 1. This product has been evaluated and is.in compliance with the 2007 Florida Building Code (FBC)structural requirements excluding the"High Velocity Hurricane-Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used..in areas requiring wind.borne debris protection this product complies with Section 1609:1.2 of the FBC and'does not require an impact resistant covering. This product meetsmissile level"M and excludes Wind Zone 4 as defined in ASTM E 1996. 4. For-2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate 'from the details of. drawing FL-5891-.2 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-5891.2 for size and design pressure limitations. Wendell e ,P.E. FL No. 415 May 1,2008 PF863 Sheet 2 of 3 Supporting Documents A Drawing 1. Drawing No.FL-5891.2 prepared by R W Building Consultants;Inc. (Florida Board of Professional Engineers Certificate of Authorization No.9813),signed and sealed by Wendell W.Haney,P.E. B Tests I Testing per TAS 202-94 as performed by Testing Evaluation Laboratories,Inc.and reported in-test report ETC 01-741-1070, 0.0,.dated September 4,2001,signed by Wendell W.Haney,P.E. 2. Testing,per SSTD 12-99 as performed by Certified-Testing Laboratories and reported in test report CTLA 980W,dated November 4,2001,signed by Ramesh Patel,P.E. C Calculations 1. Product anchoring for tested specimens is in accordance with manufacturer's published recommendations as substantiated by tested specimens reported in test report ETC 01-741- 10700.0 and CTLA 980W. Additional product anchor analysis for loading conditions prepared,signed and,sealed by Wendell W.Haney,P.E. 2. Buck anchof analysis for-loading conditions prepared,signed and sealed by Wendell W. Haney,P.E. D Other I Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISOJEC 17020 and Guide 53. Wendell W y:, E. Fl,No.54158 May 1, 2008 PF863 Sheet 3 of 3 THERMANTRU 37.59°MAX.O.A, FRAME WIDiH i G�gm�e THERMA TRU DOORS q,,� ZZ 1 1 9 D INDUSTRIAL DR., EDGERTN, QH 4351 7 W TEL. (419)298-174E3 ly YPANEL NELWIDTDTH T1z "g`n3 m r rr r rr Hill, v rr 30 )C6 � c� � SMOOTH STAR" L �� v FIBERGLASS SINGLE DOOR INSUVING/OUTSWING CD "IMPACT" z GENERAL NOTES p ® w I. This product has been evaluated and is in compliance with the 2007 Horido Building Code o (F3C)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as fated and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. m e 3. When used in areas requiring wind bome debris protection this product comptleswith Section 1609.1.2 of the FBC and does not require an impact resistant covering.This v product meets missile level"D"and excludes Wind Zone 4 as defined in ASTM E1996. a 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown L— • for 2x buck masonry construction. En d 5. Site conditions that deviate from the deto ls of this drawing require further engineering analysis by a licensed engineer or registered architect. u m g TABLE OFCONPEMS ti SHEETS DUCRIPTTON o i 1 Typical elevations,design pressures 5 general notes ASYERAL! DESfGN t?RESSURE(ASF7 i 2 Door paneldetails $Wtl!fORAhlfr k o D i 3 Horizontal cross sections pfl4fEh1S14N POSRiVE %d OATtVE nve: 4123108 i INSWING 37,59"x 82.19" +67,0 -67.0 s� N.T.S. 4 Vertical cross sections 'm 5 Buck and frame anchoring.2X buck nwsonry construction M.en AL komeanchoring-1Xfwckmosonryconstruction OUTSWING 37.59"x 80.69" +67.0 •67.0 ak,er. .WivH 3 7 BW of Materials b Cornponenis rc D0.1V,7HC rro.: F1.-5891.2 0 i s¢Er -I Dr 7 " EXTERIOR 46 G1I 43-;, 43INTERIOR46 1 HORIZONTAL CROSS SECTION 2a � `.2 � 2 1.18' r d EXTERIOR INTERIOR n ® 1 42 OR TOP 1 49 IATt [E �—2.39'— o i Smooth star .-I 1.18 h \ O A 3 2 1/ER7ICAL CROSS SECTION I$ 2 DAIS 4 23 08 z f mqz. N.T.S. 5 F 44 H1N !E 45 DOOR BiM, bl! bwc.9Y: AL o act BY, iAV)4 3 1 DRUM NO-. C 0 F7.-5891.2 °a ww or 7. 4 lU E e ® INTERIOR 10 d P3333 3 17 EXTERIOR I 1 s 340 7 3 3 8 j 1 LU 0 Od04 JA a Z 1;—U 20Ny 4 CIl4"MIN, I N D '• z `' Y • � 3 4 EMB.(TYP.J K3 0 4 4 3 HORIZONTAL CROSS SECTION L & ° 3 Shown w/1X sub•bucK substituting + a a conaete screNs for wood screvrs per 27 Section 1714.5.4.2 of the EBC m INTERIOR INTERIOR 10 9 10 p woo. \ 4 �a R Z2t= ZZ 1 e - < I EXTERIOR EXTERIOR ° f ' c 7 o� j 8 40 oC 4 baa °• y 1 B � V °+ :�.>-a � zz a o� µ 20 - o K K a° ma 4/23/1 i 20 EMB.(TYP.j ow gn C o swe N.TS. pB oea ev: AL m'MIN. E cWWH 3 y EMB. �11 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SEC1701Ym 1.114"MIN. OWING ta.: vlnsw ng configuration 3 by ing coni:gurotion EMB.(TYP.) FL-5891.2 a S sr a7 1• of 7 I"MIN.FROM I"MIN.FROM —MASONRY EDGE -MASONRY EDGE—r.- n \o (TYP.) 2-1/2"MIN.FROM 2-1/2"MIN.FROM. •�m �a v - - MASONRY EDGE--.— MASONRY EDGE (TYP.) j (TYP.) p_ L d f_. i s — 9�11 o S Ct e INTERIOR �J EXTERIORB INTERIOR EXTERIOR 1 VERTICAL CROSS SECTION r�VERTICAL CROSS SECTION 4 Inswng configuration q ShovmsvJlA sutrtwck substiiulingI o concrete screws for wood screw'per Section 1714.5.4.2 of The FEC a m INTERIOR / / EXTERIOR T ; EXTERIOR INTERIOR U) • 40 ` 32 8 N �3D3 40 / 18 4123108 1i sum, N.T.S. 9 3 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION owc AL e CW.m WWH 4 Inswing configuration DWHU ao.. c ( q Oufsv�ng configuration FL-5891.2 °o 0 SHEU 4 OF .a Q 10 0 5 a&m� ro TYP.HEAD& MASONRY E MASONRYJ JAMBS OPENING OPENING SEE NOTE 1 FRAME K' -- —} VP.HEAD JAMBSi' z w ix 2X BUCK— °0 c 2X BUCK " mo m LIT $ a m y " BUCK ANCHdRING STRIKE JAMS FRAME ANCHORING HINGE JAMS Mosonry 2X buck cosutnaction B n ti NOTES: b10 o 1. Ile Elco Concrete screws anchoring 2x buck require a minimum 1"ctearonce to masonry edges.a 1-114"minimum embedment and a Q y z y minimum 4"cloorance to adjacent concrete screws.Substitution of equal concrete screws from a different suPPlier may have different 27 atc ¢ 23/08 z edge distance and center distance requirements.Concrete screw locations at the comers may be adjusted to maintain the minimum scut: N.T.S.g edge dstance to mortar joints.If Concrete screw locations noted as"MAX:ON CHNTER"must be adjusted to maintain the minimum edge distance to mortarjoints.additional Concrete screws May required to ensure the maximum on center dimension is not an,or.. AL exceed ax Sr: VAVH ed y MWNG an_ HINGEDEIAtt LATCH&DEADSOETDETAIL FL-5139).2 a xfsr 5 Gr 7 S e v .Ai t --t m e MASONRY OPENING 1 2$ G SEE NOTE 2 r; L /1 J x 27 G SEE NOTE 2 FRAME mz TtP.HEAD& u; JAMBS W u cs SEE NOTE 1 o N z --- ¢ ho 1X BUCK LATCH a DEADSOLTDETAIL a � a a STRIKE JAMB FRAME ANCHORING HINGE JAM& x Masonry 1X buck construction i 3 - u NOTES: SEE NOTE 1 #{ o J, i/4"tTWconerafescrewsanchoring frame and/or sill require d.minimum2-1/2"cleorencetomasonry edges,a x t 1-T/4"minimum embedment and a minimuin 3"cfearonce to adjacent concrete screws. Substitution of equal Tfl concrete screws from a different supplier may have different edge distance and center distance requirements. 1Q = m ' Concrete screw locations of the comers may be adjusted to maintain the minimum edge distance to mortar 4 a '' joints.If Concrete screw locat,ons noted as MAX.ON CENTER"must be adjusted to maintain the minimum edge 2 m distance to mortaticints,additional Concrete screws may be required to ensure the maximum on center a+r 41231 08 z dimension is not exceeded. sero+ N.T.3 ° jawe.ar: AL m 2. 3116"ITW concrete screws anchoring frame anis/or sill require a minimum 2-5/8°clearance to masonry edges,a � t WWH 3 t-i/4"minimum embedment and o minimum 2-1%41 clearance to adjacent concrete screws unless otherwise HINGE DEWL �m N_ noted by concrete screw manufacturer. ° Ft--5891.2 0° ari SILL OF MATERIALS 9-t 17EM DESCRIPTION MATERIAL A 1X BUCK SG-0.55 WOOD 8 2X BUCK SG—0.55 WOOD 2.367 C MAX.I X SHIM SPACE WOOD D 1/4X 2-3/4'PFH ELCO CONCRETE SCREW STEEL 19 20 MASONRY-3.192 PSI MIN.CONCRETE CONFORMING TO ACI E CONCRETE .301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 G 13116'X 3-1/4'PFH ITW CONCRETE SCREW STEEL H 114'x 3-1/4"PFH ITW CONCRETE SCREW STEEL J 1'14'X 3.314"PFH ITW CONCRETE SCREW STEEL K #8 X 2-I17'PFH WOOD SCREW STEEL L #10 X 7 PFH WOOD SCREW STEEL 7 SHORT REACH COMPRESSION WEATHER-STRIP(THERMA-TRU) FOAM 8 LONG REACH COMPRESSION WEATHER-STRIP(THERMA-TRU) FOAM 9 4X4"HINGE.097"THK.(THERtAA-TRU) STEEL f C.D 10 010X 31C PFH WOOD SCREW JHINGE TOFRAME) STEEL 17 KWIKSET TITAN 700 SERIES PASSAGE LOCK STEEL T- 1 IS LOW PROFILE OUfSWNG BUMP FACE THRESHOLD(THERMA-TRU).W WALL AL. AWM,/WOOD 19 HEADER JAMB f4"'X 1.26-THERMA-TRU,PINE) WOOD 20 SIDE JAMB(4.656'X 1.25'THERMA-TRU) WOOD 21 KWIKSEI TITAN 700 SERIES DEADBOLT STEEL 27 LATCH STRIKE PLATE STEEL 28 DEADBOLT PLATE STEEL 32 DOOR BOTTOM SWEEP PVC 33 SELF ADJUSTING INSWING SADDLE THRESHOLD(.46-WALL AL.-.08w WALL VINYL) ALUM.COMP. 40 FIBERGLASS DOOR PANEL-SMOOTH STAR c 41 FC/SS DOOR SKIN.070"MIN.THK.FIBERGLASS BY SMC THERMA-TRU WITH YIELD STRENGTH Fy IMN.)=6,000 PSI 42 TOP RAIL COMPOSITE 43 LATCH STILE LVL WOOD 44 HINGE STILE WOOD 45 BOTTOM RAIL COMPOSITE L 46 POLYURETHANE FOAM CORE-BASF 1.9 LBS.DENSITY FOAM 47 LOCK BLOCK REINFORCEMENT WOOD t 0 M, 4123108 li � N.T.S. om m AL as by. WWH FL-5891.2 VaT or -Do 0 T�- R W Building Consultants, Inc. w Consulting and Engineering ervices for the Building Industry B P.O.Box 230 Valrico,FL 33595 Phone 8 13.639.9197 C J Florida Board of Professional Engineers Cerlificale.of Authorization No.9813 r'ebruary 24,2012 RE: Florida Product Approval FL-5891 R1 s t:) —5891.6) L Product Evaluation Reports and Drawing (FL-5391.1 Swinging Exterior Door Assemblies for Tberma-Tru Corporation To Whom It May Concern: Affirmation 'Conforinaiteeiothe 2OlOFlorlriaBtsililipggeo(le The products referenced above in this Product Approval were previously approved and found in conformance to the 2007 Florida Building Code.(FBC). In addition,RW Building Consultants and Lyndon F.Schmidt.P.E. have determined that these products are also found to be in conformance to the 2010 FBC. The Product 6-valuation Report(s)and Installation Drawing(s)remain unchanged. % cc d. 0. 0 Lyndon F'. Schmidt, P.E. " ..A.....V'y' 0 'r FLT 43409 4' lowol., I RW Building Consultants, Inc. CA No.9813