HomeMy WebLinkAboutInspection Docs AC AccoRex, Pips Insulation
1letiiEriptlQp9 .. .
Black flexible elastomaric thermal pipe insulation
'Sge dfiGltw"COMO";&
ASTM C 534,Type f-Tubular Oradt:I
•Manufactured without CFCs.HFCs,HCFCs,PBDEs,or f=ormaldehyde. •ALL Armaceti facilities in(North America are ISO 4001:2006 certified.
5prtifitttiprwp: lfattms 'Titf►t�Aelfhttd:
Ther"Conductivi ..
13tu•fn./h-fF-aF%C/mK?
75°F Mears Temperature 124°CI 0.2710-0391 A5TM C 177 or C 518
981F Mean Temporatuco 122°C1 0.276(0.0401
Wat&r Vapor Permeability- [LOS 11-16 x 110•a1 ASTM E 96,Procedure A
Perm-in.{Ftg/is-m•Pall
Flame Spread and Smoke 25150 rated ASTM E64
Devetopedfodem
Water Absorptk4 0.2% ASTM C 209
04 by Volume:
Mold Orowth: passed UL181
Fungi Resistritice. ASTM G21/C133S
Etacterisl statue: ASTM 022
upper Use limit- 220°F 1105°Cl ASTM C634
Lower Use Llmitt -297°F(-183'C13 ASTM C534
Ozone Rosirtanca- GOOD ^-
Wall Thickness(nominitti 3/8"1/2",3/4"and 1"110,13.19 and 25mm)
inside Diameter,T'ubulvr 3/8",1D to 4-1/8"10(10mm,to to 105mm ID)
Length of Sections,Tubular 6.11.83mi
Outdoor Use No painting is necessary for performance of the product.However,all elaslomeric-based cellular
insulation will show surface defects after prolonged exposure to i1V radiation.Painting will
minimize these defects if fnwalted outdoors.
on the heating cycle,AC Attoftex pipe insulation wifhwithatand temperatures as high as 220"F 0 Ua"CI.520.520 Black or 520 SLVAdhdslva may be used with pipe Insulation
applications up to 220°F 1105"i<1,
At temperatures Wow-20°1:1-29'Cl.etastomedc insulation start.to be4ume less flexible-However,this ehaNauristic does not affect thermal efficiency and roslsfunce Ea waW,
vapor permeability afAccaflax insulation.
=
For applicatiom of 4WF to-2WOF1.404C to-183°C),contact ArmarxLL
IIRMCIELL LLC
TEL:8M.866.5625 to
FAX:919.304.W47
aceu. a r m a e l l
infa.usl8afmacetl.cort't
%ww armacelLus
7600 Oakwood Street Extension,Mebane,SNC?73112 advanced insulation
Armaceilprovides this information ns a technical serulce,To the extent the information is deriwd from sources other than Armaca0,Arnwcett is substantially,if not wh*4relying upon
the other source151 to provide aceintt information,Wormation provided as a result of Armsceirs own technical analysis and testing Is accurate to the adoM of our knowledge and
ability,as of date of printing,using effective oittndardiZCd•methods and procedures.Each user of these product$,orinformation,should performs their mit tests to determine the safety,
ift"ss and'%uitahility of the products,or combination of products,for any foraucable purposes,appikations and uses by the user and by any Wed party to which the user"me convey
the products.Since cell cannot control the and t sc of the$ uctt,ArmacciL does not guarantee that the usorwilt obtain the same results os publlshad in this document,The dais
and information am provided as a technical snrvhce and or-sub cot to dmnge without notice.
A�CRrcollmt Submittal G0fv1G EngJtJSA. 412at4
0 2014 Annaceu LLC.Pfkud in Uoilod Stator of runorica
ZO 39Vd
�tilSW l�SHS 1SGS�1�S LZbZ99bZLL 61:80 5Z0Z/EZ/90