ASCE 7-10&FBC 2010 ENCLOSED BLDG
SEMI ENCLOSED BLDG OPEN
PART 2 LOW RISE C&C SIMPLIFIED
RISKCA12/V= t(oo EXPOSURE
Kzt, 1,0/h /12 PITCH
ROOF SYSTEM—a e-,ce2 d 1 tlF•"�
ZONE 1 P @ @ h=30 = X = PS F x 0.6
ZONE 2 P @
@ h=30 = X = PSF x 0.6
7
ZONE 3 P @a=
@ h=30 X PSFX0.6=
MAX DESIGN PRESSURE PER NOA tp
DECKTYPE THICKNESS
BASE SHEET C"-- NO,OF PLIES FASTENERTYPE SPACING
PLY SHEET — NO.OF PLIES FASTENER TYPE SPACING—
TOP PLY — NO,OF PLIES FASTENER TYPE SPACING
INSULATION BASE LAYER TYPE SIZE
TYPE OF FASTENERS: SPACING FIELD PERIMETER CORNERS
INSULATION TOP LAYER TYPE SIZE
TYPE OF FASTENERS) L 10-1'� X III PA*4,k(4F- R W000 44
DRIP EDGE SIZE !3X DRIP MATERIAL 2(o 4nk FLASHING MATERIAL 2e,
FASTENER SPACING FOR METAL ROOF PANELS: FIELD— Ap PERIMETERS CORNER
T reasure Harvey E. Koehnen
C Oast Professional Engineer#32831
B uilding Architect #AR0009471
E ngineers., Certified General Contractor #CGCO24776
Inc.
These Tables Are For Roof Coverings
Roof coverings Installed on Buildings with a
Mean Roof Height of 30'or Less Located In Exposures B, C or D
Table R301.2[2]off. !'t Gnu a S-(A5-f 7-Ih
COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE rPSF].
160 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D
(One story . (Two story*) (One story") (Two story
Roof> 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9
7degrees= 11/2/12 pitch Zone 2 -46.4 -56.2 -65.0 --68.3 -77.1
Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9
�<
C27-degrec-8
7 to 27 degrees Zone 1 -5 3 -30.7 -35.5 -37.2 -42
=6/12 pitch Zone 2 -44.1 -63.4 -61.8 -64.9 -73.3 \�
Zone 3 -65.1-` '-78.8 -91.2 - 95.7 - 108.. �`11p
Roof>27 to 45 degrees Zone 1 -27.8 -33.7 -40.0 -40.1 -46:2 l
45 degrees= 12/12 pitch Zone 2 -32.4 -39.3 -45.4 -47.7 -53.8
Zone 3 -32.4 -39.3 -45.4 -47,7 -53.8
.150 Exp B 150 Exp C 150 Exp C 150 Exp D 150 Ezp D
(one story*) (two story*) (one story*) (two story)
- R66f 0 to,7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4
7de-F es,=1,1/2/12 pitch Zone 2 -40.8 -49,4 -57.2 -60.0 -67.8
_
-J. Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0
= P,dof>7 to 27egrees Zone 1 -22.2 -26.9 -31.1 -32.7 -36.9
27 degrees'=6/12 pitch Zone 2 -38.7 -48.9 -54-2 -56.9 -84.3
�. Zone 3 -57,3 -69.4 -80-3 -84.3 -95.2
-Roof>27-f' 45 degrees Zone 1 -24.3 =29.5 -34.1 -35.6 -40.4
45.dejrees= 12/12 pitch Zone 2 -28.4 34.4 -39.8 -41.8 -47.2 -
Zone 3 -28.4 -34.4 -39.8 -41.8 -47.2
One story*= one story building with a maximum mean roof height of 15 feet
Two story=two story building with a maximum mean roof height of 30 feet
If-allowed by the Miami Dade N.O.A or Florida Product Approval., any-system-that does not meet the
minimum components and cladding pressures for the area that the building is located per this form
m8y require a Florida licensed engineer to revise the fastener spacing