Loading...
HomeMy WebLinkAboutEngineering T reasurp Harvey E.Koehnen 7205 Elyse Circle Coast Professional Engineer#32931 P S L Florida 34952-8212 B uIlding Architect OAR0009471 PHONE(772)466-5509 E ngineers, Certified General Contractor 9CGCO24776 FAX(772)489-3035 Inc. E-MAILhkoehnen@tcbeweb.com Contractor Owner . /1 r-f-- Date 0 Job Addregs 0.2,e<--0,p METAL ROOFING T ZzK.,�ZcKz—m v -L o c RECEI VLc NEW ROOF RE-ROOF REPAIR AREA 4*7'SQp D jUN24.20a METAL ROOF PLAN FILE cop)( 1\I I I I Al I 1 1/1 1 1 1 1 1 1 tt . l 11 I IA I I I* I III I I I 1\1 I A 114 171 1 11 1 1 1 1 1 1 I I -xr I 111(o1 1 1 1 1 1 1 11111FVN IIIIIII 111111 . I I I I IA ISI NI -1 1 1 1 F-1 I I 1111 �ip Rod (70 ,< 0< 270) T- I I III 1 11111 11 I III 11111 11 11 111 111 II 1 11111H ASCE 7-10&FBC 2010 ENCLOSED BLDG SEMI ENCLOSED BLDG OPEN PART 2 LOW RISE C&C SIMPLIFIED RISKCA12/V= t(oo EXPOSURE Kzt, 1,0/h /12 PITCH ROOF SYSTEM—a e-,ce2 d 1 tlF•"� ZONE 1 P @ @ h=30 = X = PS F x 0.6 ZONE 2 P @ @ h=30 = X = PSF x 0.6 7 ZONE 3 P @a= @ h=30 X PSFX0.6= MAX DESIGN PRESSURE PER NOA tp DECKTYPE THICKNESS BASE SHEET C"-- NO,OF PLIES FASTENERTYPE SPACING PLY SHEET — NO.OF PLIES FASTENER TYPE SPACING— TOP PLY — NO,OF PLIES FASTENER TYPE SPACING INSULATION BASE LAYER TYPE SIZE TYPE OF FASTENERS: SPACING FIELD PERIMETER CORNERS INSULATION TOP LAYER TYPE SIZE TYPE OF FASTENERS) L 10-1'� X III PA*4,k(4F- R W000 44 DRIP EDGE SIZE !3X DRIP MATERIAL 2(o 4nk FLASHING MATERIAL 2e, FASTENER SPACING FOR METAL ROOF PANELS: FIELD— Ap PERIMETERS CORNER T reasure Harvey E. Koehnen C Oast Professional Engineer#32831 B uilding Architect #AR0009471 E ngineers., Certified General Contractor #CGCO24776 Inc. These Tables Are For Roof Coverings Roof coverings Installed on Buildings with a Mean Roof Height of 30'or Less Located In Exposures B, C or D Table R301.2[2]off. !'t Gnu a S-(A5-f 7-Ih COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE rPSF]. 160 Exp B 160 Exp C 160 Exp C 160 Exp D 160 Exp D (One story . (Two story*) (One story") (Two story Roof> 0 to 7 degrees Zone 1 -27.6 -33.4 -38.7 -40.6 -45.9 7degrees= 11/2/12 pitch Zone 2 -46.4 -56.2 -65.0 --68.3 -77.1 Zone 3 -69.8 -84.5 -97.7 -102.7 -115.9 �< C27-degrec-8 7 to 27 degrees Zone 1 -5 3 -30.7 -35.5 -37.2 -42 =6/12 pitch Zone 2 -44.1 -63.4 -61.8 -64.9 -73.3 \� Zone 3 -65.1-` '-78.8 -91.2 - 95.7 - 108.. �`11p Roof>27 to 45 degrees Zone 1 -27.8 -33.7 -40.0 -40.1 -46:2 l 45 degrees= 12/12 pitch Zone 2 -32.4 -39.3 -45.4 -47.7 -53.8 Zone 3 -32.4 -39.3 -45.4 -47,7 -53.8 .150 Exp B 150 Exp C 150 Exp C 150 Exp D 150 Ezp D (one story*) (two story*) (one story*) (two story) - R66f 0 to,7 degrees Zone 1 -24.3 -29.6 -34.1 -35.8 -40.4 7de-F es,=1,1/2/12 pitch Zone 2 -40.8 -49,4 -57.2 -60.0 -67.8 _ -J. Zone 3 -61.4 -74.3 -86.0 -90.3 -102.0 = P,dof>7 to 27egrees Zone 1 -22.2 -26.9 -31.1 -32.7 -36.9 27 degrees'=6/12 pitch Zone 2 -38.7 -48.9 -54-2 -56.9 -84.3 �. Zone 3 -57,3 -69.4 -80-3 -84.3 -95.2 -Roof>27-f' 45 degrees Zone 1 -24.3 =29.5 -34.1 -35.6 -40.4 45.dejrees= 12/12 pitch Zone 2 -28.4 34.4 -39.8 -41.8 -47.2 - Zone 3 -28.4 -34.4 -39.8 -41.8 -47.2 One story*= one story building with a maximum mean roof height of 15 feet Two story=two story building with a maximum mean roof height of 30 feet If-allowed by the Miami Dade N.O.A or Florida Product Approval., any-system-that does not meet the minimum components and cladding pressures for the area that the building is located per this form m8y require a Florida licensed engineer to revise the fastener spacing T C B E,Inc. 7205 Elyse Circle PHONE (772)466-5509 Port Saint Lucie FAX (772)489-3035 Florida 34952-8212 E-MAIL hkoehnen@tcbeweb.com WEB sr-rE http://www.tcbeweb.com