Johns Manville Corporation
71717th Street
Denver,CO 80202
SCOPE:
This NOA is being,issued under the applicable rules and regulations governing the use of construction
materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product
Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner, the manufacturer ,xrill incur the expense of such
testing and the AHJ may immediately revoke, modify,or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code,
DESCRIPTION:Johns Manville APP Modified Bitumen Roofing Systems Over Wood Decks.:- 7�-
LABELING:Each unit shall bear a permanent label with The manufacturer's name or logo,city,state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no-change in-the applicable building code negatively affecting the.performance--of this product.
� - dguqt,
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement
of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure
to comply with any section of this NOA shall be cause for termination and removal of NIOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 12-0123.06 and consists of pages I through 15.
The submitted documentation was reviewed by Jorge L.Acebo.
NOA No.:13-0129.03
MICMNTY WADECCUExpiration Date: 06/14/16
�) Approval Date: 06,106/13
Page I of 15
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Cate"ry: Modified Bitumen
Materials: APP
Deck Tvpe: Wood
Maximum Design Pressure -52.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
JM APP Base 39-3/9"x 48' ASTM D 6509 APP modified asphalt,fiberglass
reinforced,smooth surfaced base sheet.
APPeX 4S 39-318"x 34' ASTM D 6222 APP modified asphalt,polyester
Type I reinforced,smooth surfaced membrane
Grade S for use as a Base and/or Ply Sheet only.
APPeX 4.5M 39-3/8"x 34' ASTM D 6222 APP modified asphalt,polyester
Type I reinforced,mineral surfaced membrane.
Grade G
APPeX 4.5M FR 39-3/8"x 34' ASTM D 6222 APP modified asphalt,polyester
Type I reinforced,fire-retardant,mineral surfaced
Grade G membrane.
Tricor MFR 39-3/8"x 34' ASTM D 6223 APP modified asphalt,polyester/'glass
reinforced,granule surfaced membrane.
Tricor S 39-318"x 34' ASTM D 6223 APP modified asphalt,polyester/glass
reinforced,smooth surfaced membrane
for use as a Base and/or Ply Sheet only.
PermaPly 28 36" x WO; ASTM D 4601 Ty-pe IIasphaltimpregnated and coated
721b.roll glass fiber base sheet
Ventsulation 36"x 36' ASTM D 4897 Heavy duty fiber glass base sheet
C�
Type 11 impregnated and coated on both sides with
asphalt with or without fine mineral
stabilizer,
GlasBase Plus 36"x 106' ASTM D 4601 Type H SBS and asphalt blend
impregnated and coated glass fiber base
sheet with fine mineral stabilizer.
INOA No.: 13-0129.03
MLAMI-DADECOUKM Expiration Date: 06114116
Approval Date: 06106t13
Page 2 of 15
Membrane Type: APP
Deck Type 11: Wood,Non-Insulated
Deck Description: '962"or greater plywood or wood plank
System Type E: Base sheet mechanically fastened.
All General and System limitations apply.
Base Sheet: A Base a lasba e Plus or
IS G 'e Plus or
h ast, : G Roofgrip
row
pe� Ply� �M
s e 0 ed deck w i
es fastener L lap 12 and two row
%as
c 4 e P' PP
0 faster
n n �ha Y� y f
V T' u' t10 me f la and f ten r at a4 sjdc
r
n th cil er of t 18, c_
0 d it th be
sta_ - e
e e e
.111111 1 Ign Pressure-45
Ps
f
n es v See LimItallon 49.�
Vax D e 49.)
el"t-
V (Option#2)Minimum twopli'es of JM PermaPly 28 or Ventsulation
simultaneously fasteneJlto the deck lapped 4"anrfastened with approved roofing
nails and tin caps 9"o.c.at the lap and two rows staggered in the center of the
sheet 12"o.c.
011axintunt Design Pressure-52.5,pif,See General Limitation#7.)-
( tion#3)Minimum,A,;ro'plies ifJMPernmnaPly28orV'en lation
-8 or
Tj
siWtaneously faslefied to the deck\yvith JM Ultrafast eners and Me I Plates
t t i
spat 9"0.c.�a 4"lap and 12"o.c. n two stagger rows in the center - e
sheet.
(Alavimum Design Pressure-52.5 psf,See General Limitation#7.)
Piy,Sh I"...
pito ne p1jie"-HM APP Bd.,N, or AP 4S heat'�cldeftg_�as
S='X:=1eai=taini= e Li id S.
Membrane: One or more plies of APPeX 4.5M or APPeX 4.511 FR heat welded while
maintaining 4"side laps-a-n='end laps.
Surfacing. Optional)Install one of e fo owing for a Ste I 1.i t d 0 n
eptable firexating 14e of F1 ine--Tr-l^-e s ts not achieve
ny coati listed
be w,used as a s
acing,must b listed with` a current
1 400 ./sq.gran or 300 lb./sq.slag a flo d coat of approu moppi g asphalt at
aa rate f6101 Aq.
2. 7 amak 97 AF, N,4onsey P tum Long Life Alumin oof Coating
Karnak
Asbesta ce or Monsey Prograde num, Grundy AL MB a num coating,
at a r e of 1/2 gal/sq.Monsey uabrit Gardner asphalt ern sio APOC
r"
S right 40 or Henry 229 Al inum Emu ion at 21/2 gaLls or APO 212
uminum Roo Coating at 3 al/sq,
3 Grundy 20 F aspl It emu] Endure Asphalt E Ision,F POC 302 or 30
applied at 2V2 gal/sq. -' optional 60 tbs./sq.of roo i anules embedded in wet
coating.
Maximum Design
Pressure: See Fastening Options
NOA No.:13-0129.03
QMI"A"MI- MDECMOU Expiration Date; 06114i16
r-jigaorig) Approval Date: 06[06113
Page 14 of 15
WOOD DECK SYSTEM LIMITATIONS:
I A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor
sheet.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically
attached using the fastening pattern of the top layer
3
All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt,panel size shall be 4'x 4'maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows,one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq,
Note: Spot attached systems shall be limited to maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of
275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested,are below 275 lbf insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required,as determined by the
Building Official,a revised fastener spacing,prepared,signed and sealed by a Florida Registered
Engineer,Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
417. -Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener denstties shall be increased fdf- both-iimhdw-and-base-sheet-as-calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation#9 will not
be applicable.)
8. Al I attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e.
field,perimeters,and comers). Neither rational analysis,nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones(i.e.perimeters,extended comers and comers).
(When this limitation is specifically referred within this NOA,General Limitation#7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE