Loading...
HomeMy WebLinkAboutEngineering ASCE 7-10 Wind Calcs . Date 6/24/2015 Project No. 15KWD02 Company Name Consulting Engineer Designed By Darren Spence, P.E. Address 10725 NW 17th St. Description ASCE 7-10 Wind Calcs. �Age City Coral Springs Customer Name : Newton State FL Proj Location : 9550 S. Ocean Dr., #102 Jensen Beach, FL 34957 Input Parameters: Directional Procedure All Heights Building (Ch 27 Part 1) Basic Wind Speed(V) = 170.00 mph Structural Category = II Exposure Category = D Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Damping Ratio (beta) = 0.01 Alpha = 11.50 Zg = 700.00 ft At = 0.09 Bt = 1.07 Am = 0.11 Bm = 0.80 Cc = 0.15 1 = 650.00 ft Epsilon = 0.13 Zmin = 7.00 ft Pitch of Roof = 0 : 12 Slope of Roof(Theta) _ .00 Deg h: Mean Roof Ht = 200.00 ft Type of Roof = MONOSLOPE RHt: Ridge Ht = 200.00 ft Eht: Eave Height = 200.00 ft OH: Roof Overhang at Eave= .00 ft Overhead Type = No Overhang Bldg Length Along Ridge = 180.00 ft Bldg Width Across Ridge= 80.00 ft Gust Factor Calculations Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 120.00 ft lzm: Cc*(33/Zm)^0.167 = 0.12 Lzm: 1*(Zm/33)^Epsilon = 763.83 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.87 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.87 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCPi GCPi Internal Pressure Coefficient = +/-0.18 pe �S3g8'6 Scanned by CarnScanner Wind Pressure on Components and Cladding (Ch 30 Part 3) a a 2a 2a 3a 2 3 1------------- F- 2 2a ----- -- � 1 21 , , �l S� i � 1 i -"-of i $ � 1 z , ----------------- 33 2a + , t 1 1 2 Walls Heieht>60 ft. Roof All pressures shown are based upon ASD Design, with a Load Factor of .6 Width of Pressure Coefficient Zone "a" = = 8.00 ft Description Width Span Area Zone Max Min Max P Min P Elev ft ft ft^2 GCp GCp psf psf ft --------------------------------------------------------------------------- 8' x 8' SGD more than 8' from building corners 8.00 8.00 69.0 9 0.79 -0.83 59.26 -61.96 200.0 8' x 8' SGD less than 8' from building corners 8.00 8.00 69.0 5 0.79 -1.51 59.26 -103.13 200.0 12' x 8' SGD more than 8' from building corners 12.00 8.00 96.0 9 0.75 -0.80 56.96 -59.92 200.0 12' x 8' SGD less than B' from building corners 12.00 8.00 96.0 5 0.75 -1.91 56.96 -96.98 200.0 2- Scanned Scanned by CamScanner