HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
� k, ff 1 • f • Q 'S' �� �% x
V
Florida Depernentof BCIS Home I Log In user Registration Hot Topics I Submit Surcharge Stats&Facts I Publications (FBC Staff I BCIS Site Map (Links I Search
3usines m
Professil"dl
0 Product Approval
.USER:Public User
Regulation
1. Product Approval Menu>Product or ADDlication Search>Application List>Application Detail
FL# FL10124-1112
Application Type Editorial Change
Code Version 2010
Application Status Approved
Comments
Archived I]
Product Manufacturer GAF
Address/Phone/Email 1361 Alps Road
Wayne,NJ 07470
(973)872-4421
lindarelth@trinityerd.com
Authorized Signature Beth McSorley
lindarelth@trinityerd.com
Technical Representative Beth McSoriey
Address/Phone/Email 1361 Alps Road-Bldg 11-1
Wayne,NJ 07470
(973)872-4421
BMcSorley@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who Robert Nieminen
developed the Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/16/2015
Validated By John W.Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL16124 R12 COI 2014 04 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161(Class F) 2006
ASTM D3462 2007
ASTM D7158(Class H) 2007
TAS 107 1995
Equivalence of Product Standards
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquracBeVCbdM... 11/5/2014
Florida Building Code Online Page 2 of 2
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/28/2014
Date Validated 08/29/2014
Date Pending FBC Approval 09/01/2014
Date Approved 10/15/2014
Summary of Products
FL# Model,Number or Name Description
10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab,laminated,5-tab and
hl /ridge asphalt shingles
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10124 R12 II 2014 08 FINAL ER GAF Asphalt
Approved for use outside HVHZ:Yes Shingles FL10124-R12. df
Impact Resistant:N/A Verified By: Robert Nleminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER,Section 5. Evaluation Reports
FL10124 R12 AE 2014 08 FINAL ER GAF Asphalt
Shin les FL10124-R12. df
11 Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street.Tallahassee Fl,32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
send electronic mall to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.
'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which an be made available to the public.
To determine if you are a licensee under Chapter 455,F.S.,please dick LUL.
Product Approval Accepts:
SWorli xICTRICV
MOM
http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDquracBeVCbdM... 11/5/2014
t '
EXTERIOR RESEARCH &DESIGN, LLC.
Certificate of Authorization#9503
353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1114
1361 Alps Road, Building 7-3 FL10124-R12
Wayne,NJ 07470 Date of Issuance:01/03/2008
Revision 14:08/28/2014
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by: `Uupt�rr„r,�
- itr
The facsimile seal appearing was authorized
+�O�'�p-,� •1a,i+��' by Robert Nleminen,P.E.on 08/28/2014
.c�..!, �...
Robert J.M.Nieminen,P.E. �yonra�'41dp: This does not serve as an electronically signed document Signed,
Florida Registration No.59166,Florida DCA ANE1983
3+;�Aliil 1%, sealed hardcopies have been transmitted to the Product Approval
Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
\\]
TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following
sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2007
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161,Class F 2006
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158,Class H 2007
1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS 107 94NK9632 03/29/2000
UL(TST 1740) ASTM D3462 OINK06632 02/02/2001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST 1740) ASTM D3161 01NK37122 12/18/2001
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04%2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 ' .09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 06NK06647 08/01/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010
UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010
UL(TST 1740) ASTM D3462 IOCA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1114
Certificate of Authorization#9503 FL10124-1112
Revision 14:08/28/2014
Page 2 of 5
TRINITY] K�
Entity Examination Reference Date
UL(TST 1740) ASTM D3161,D7158,D3462 10CAS3934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011.
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,I.I.C.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,U.C.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(QUA 9625) Quality Control Inspection Report,File No.R21 12/16/2013
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis"WeatherMax",Royal Sovereign"and Sentinel"are a fiberglass reinforced 3-tab asphalt roof shingles.
4.1.2 Camelot", Camelot® II,Capstone®,Country Mansion",Country Mansion" II, Grand Canyon—, Grand Sequoia", Grand
Sequoia® IR, Grand Slate—, Grand Slate— II, Monaco°, Sienna®, Timberline" American Harvest', Timberline®
ArmorShieldT1 II, Timberline® Natural Shadow, Timberline" HD, Timberline" Cool Series, Timberline® Ultra HD and
Woodland"are fiberglass reinforced,laminated asphalt roof shingles.
4.1.3 Slateline"is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge"Ridge Cap Shingles,Seal-A-Ridge"IR Impact-Resistant Ridge Cap Shingles and TimberTex"Premium Ridge
Cap Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles.
4.3 Starter Strips:
4.3.1 Pro-Start"Starter Strip Shingles and WeatherBlocker" Premium Eave/Rake Starter Strip are a starter strips for asphalt
roof shingles.
S. LIMITATIONS:
5.1 This Evaluation Report is not for use in the HVHZ.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.3 Wind Classification:
5.3.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6:1 to
ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones_ up to
Vaed=150 mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.3.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph
(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Starter Shingles:
6.2.1 Installation of Pro-Start Starter Strip Shingles and WeatherBlocker Premium Eave/Rake Starter Strip shall comply with
the manufacturer's current published instructions.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1114
Certificate of Authorization#9503 FL10124-R32
Revision 14:08/28/2014
Page 3 of 5
�J
TRINITY I ERQ
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordance with FBC Sections 1507.2 or R905.2,with the following exceptions:
➢ Camelot,Camelot II,Grand Canyon,Grand Sequoia,Grand Sequoia IR,Grand Slate,Grand Slate II and Woodland
require minimum five(5)nails per shingle.
➢ Slateline requires minimum six(6)nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles and Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles shall comply
with the manufacturer's current published instructions with a minimum two (2) nails, minimum 3/8-inch head
diameter,per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
its. Saatant
—j7-02 mm) f• soAartte
{2s mmj Endia't dManctt�6
i!
ifall
i7a�o 12'
Muer ( )
No MM)
{ rma�
6.4.2 Installation of TimberTex Premium Ridge Cap Shingles shall comply with the manufacturer's current published
instructions with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle and beads of Sonneborn NP1
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
its,
1• t�-�rnt�t} t• /�&ellanu
(2amm1 i�mm �nd.�tfd"3tatisftlxl4
t�44a
t2"
(3e75 7[k'R`}
6.4.3 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-1114
Certificate of Authorization#9503 FL30124-1112
Revision 14:08/28/2014
Page 4 of 5
Q....-
TRINITY ERP.
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report 01506.01.08-1134
Certificate of Authorization#9503 FL10124-1132
Revision 14:08/28/2014
Page 5 of 5
Florida Building Code Online Page 1 of 2
Fi„ t i i..� �n�...��. '`I°.'ry•�•9' �`. ''J.v,E.�°?.ati'-^'� $Y ra_�e � I K �31@
Cern�F3(`tt11�(li BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links I Search y
Business
Professi real �)'" product Approval
°° USER:Public User
Regulation
IflfJ:RJ! ?:�11'I�:Litm Product Aoorodal Menu>Product or Application Search>Application List>Application Detail
r�
FL# FL5325-115
Application Type Revision
Code Version 2010
Application Status Approved
Comments
Archived O
Product Manufacturer SDP Inc.
Address/Phone/Email 410-130 Bridgeland Ave
Toronto,
(866)747-4035 Ext4
sdipede@sdp-products.com
Authorized Signature Sandro Di Pede
sdipede@sdp-products.com
Technical Representative Sandro Di Pede
Address/Phone/Email 410-130 Bridgeland Ave
Toronto
(416)780-1700
sandrodipede@bellnet.ca
Quality Assurance Representative Sandro Di Pede
Address/Phone/Email 410-130 Bridgeland Ave
Toronto
(416)780-1700
sandrodipede@bellnet.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
® Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA Inc.-.ETL/Warnock Hersey
Quality Assurance Contract Expiration Date 08/30/2015
Validated By John W.Knezevich,PE
0 Validation Checklist-Hardcopy Received
Certificate of Independence FL5325 R5 COI Trinity ERD CI-Nieminen.Ddf
Referenced Standard and Year(of Standard).
Equivalence of Product Standards
Certified By
Sections from the Code
1507.2.3
1507.2.4
1507.3.3
1`I
Florida Building Code Online Page 2 of 2
1507.5.3
1507.5.3
1507.7.3
1507.8.3
1507.9.3
1507.9.5
1518.4
1523.6.5.2.1
1523.6.5.2.9
Product Approval Method Method 2 Option B
Date Submitted 04/23/2012
Date Validated 04/25/2012
Date Pending FBC Approval 04/28/2012
Date Approved 06/11/2012
Date Revised 04/29/2015
Summary of Products
FL# Model,Number or Name Description
5325.1 PALISADE Roofing Synthetic Roofing Underlayments
Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL5325 R5 II er042212FINAL SDP UNDERLAYMENTS FL5325-
Approved for use outside HVHZ:Yes R5.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other: 1.)PALISADE is for use in non-HVHZ and Evaluation Reports
HVHZ jurisdictions.2.)PALISADE SA-HT is not for use FL5325 R5 AE er042212FINAL SDP UNDERIAYMENTS FL5325-
in HVHZ. 3.)Refer to ER Section 5 for Limits of Use. R5.Ddf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 4�5,F.S.,please click here _
Product Approval Accepts:
. SCCUCILY\ISf1iIGS
1_�a____//__—_—__11____x_1___'71'___ __ L___L__ _____ lil _ ______ __l1T�r�7l1__sT_ T___Jl_T71 1.1. r//1A/r�n1!•
5
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
T , NI .ERD OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
SDP, Inc. Evaluation Report 519010.07.09-111
410-130 Bridgeland Avenue FL5325-R5
Toronto, Ontario M6A 1Z4 Date of Issuance: 07/03/2009
Canada Revision 1: 04/22/2012
SCOPE:
This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing
the use of construction materials in the State of Florida. The documentation submitted has been
reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and
Florida Building Code, Residential Volume. The products described herein have been designed to
comply with the 2010 Florida Building Code sections noted herein.
DESCRIPTION: PALISADETm Roof Underlayments
LABELING:. Each unit shall bear labeling in accordance with the requirements the Accredited Quality
Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)
changes, the referenced Quality Assurance documentation changes, or provisions of the Code that
relate to the product change. Acceptance of this Evaluation Report by the named client constitutes
agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality
Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation
Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may
be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it
shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by
the manufacturer or its distributors and shall be available for inspection at the job site at the
request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
The facsimile seal appearing was authorized
;.S.in_.: :rp4 by Robert Nleminen,P.E.on 04/22/2012
This does not serve as an electronically signed
Robert J.M. Nieminen P.E. '•i;cS�^` ''' ' dbcvment. Signed,sealed hardcopies have been
i' �,�104a� �•`?' transmitted to the Product Approval Administrator and
Florida Registration No. 59166, Florida DCA ANE2983. Vii'-- to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it Intend to acquire or will it acquire, a financial Interest in any company manufacturing.or
distributing products It evaluates.
2. TrinitylERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial Interest in any company manufacturing or-distributing products for which
the evaluation reports are being Issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
F)o
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: PALISADETM Roof Underlayments, as produced by SDP, Inc., have
demonstrated compliance with the intent of the following sections of the Florida Building Code through
testing in accordance with the applicable sections of the following Standards. Compliance is subject to
the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.3,1507.3.3, 1507.5.3, Unrolling,Breaking Strength, ASTM D226 2006
1507.7.3, 1507.8.3, 1507.9.3, Pliability,Loss on Heating
1507.9.5, 1518.4
1507.3.3, 1518.4 Unrolling,Pliability,Behavior on ASTM D2626 2004
Heating,Breaking Strength,Water
Vapor Permeance
1523.6.5.2.1 Dimensional Stability,Tear TAS 104 1995
Resistance,Breaking Strength,
Water Absorption,Low Temp Flex,
UV Exposure,Accelerated Aging,
Cyclic Elongation,Water Vapor
Transmission
1523.6.5.2.9 Comparative Rupture TAS 117,Appendix B 1995
1507.2.4, 1507.5.3 Unrolling,Thickness,Max Load, ASTM D1970 2001
Elongation at Break,Adhesion,
Thermal Stability,Low Temp Flex,
Tear Resistance,Moisture Vapor
Permeance,Self-Sealability
TAS 110 Accelerated Weathering ASTM D4798 2001
3. REFERENCES:
Enti Examination Reference Date
ERD (TST6049) Physical Properties 54240.10.06 .10/03/2006
ERD(TST6049) Physical Properties&Rupture SO404C.12.05-R2 02/23/2009
ERD (TST6049) Accelerated Weathering S37000.06.11 06/14/2011
ICC-ES (EVL2396) IBC Compliance ESR-1847 03/01/2011
Miami-Dade(CER1592) HVHZ Compliance 11-0714.05 11/10/2011
ITS-ETL/WH (QUA1673) Quality Control Inspection Report 04/10/2012
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 PALISADETM is a synthetic roofing underlayment comprised of a polyolefin-coated; woven
construction with dual skid resistant surfaces. PALISADET14 is acceptable for use in non=HVHZ
and HVHZ jurisdictions. Refer to Limits of Use herein.
4.2 Self-Adhering Underlavments:.
4.2.1 PALISADE TM
SA-HT is a self-adhering roofing underlayment comprised of a polyolefin-coated,
woven construction with skid resistant upper_ surface and self-adhering bottom surface.
PALISADE TM SA-HT is not for use in HVHZ. Refer to Limits of Use herein.
Exterior Research and Design, LLC. Evaluation Report 519010.07.09-R3
Certificate of Authorization#9503 FL5325-R5
Revision 1: 04/22/2012
Page 2 of 6
D AA��.'
Il til 9 1 ..
5. LIMITATIONS:
5.1 For Non-HVHZ Jurisdictions:
5.1.1 Fire Classification is not part of this report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.1.2 PALISADETM Roof Underlayments may be used with any prepared roof cover where the
product is specifically referenced within FBC approval documents. If not listed, a request may
be made to the AHJ for approval based on this evaluation combined with supporting data for
the prepared roof covering.
5.1.3 Allowable roof covers applied atop the underlayments are follows:
Table 1: Roof Cover Options
Asphalt Nail-On Foam-On Metal Wood Shakes Slate
Underlayment Shingles Tile Tile &Shingles
PALISADE'" Yes Yes Yes(as base Yes Yes Yes
layer only)
PALISADE'"'SA-HT Yes No No Yes Yes Yes
5.1.4 Allowable Substrates:
5.1.4.1 PALISADE T111 SA-HT adhered to plywood or mechanically attached PALISADE T"
5.1.5 Exposure Limitations:
5.1.5.1 PALISADE TM shall not be left exposed for longer than 180-days after installation.
5.1.5.2 PALISADE TM SA-HT shall not be left exposed for longer than 30-days after installation
5.1.6 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth
Edition, use is limited to the following:
Table 2:Tile System Options for SDP Roof Underlayments per FRSA/TRI 07320/8-05
System Underlay Section Reference SDP Product(s)
Option
System One: 1 3.02A No.43 PALISADET"
Mechanically Fastened
Tile,Unsealed or 4 3.021) No.30 or No.43 PALISADE"
Sealed Underlayment
System 6 3.02F No.30 PALISADE TM(See Section 5.1.6.1)
System Two:
Mechanically Fastened 5 3.02E No.30 PALISADE'"(See.Section 5.1.6.1)
Tile,Sealed
Underlayment System
System Four"A
Adhesive-Set Tile, 5 3.02E No.30 PALISADEim(See Section 5.1.6.2).
Unsealed or Sealed
Underlayment System
Svstem Four"B":
Adhesive-Set Tile, 4 3.02D No. 30 PALISADE'"(See Section 5.1.6.2)
Sealed Underlayment
System
5.1.6.1 For System One, Option 6 and System Two, Option 5, approved underlayment systems are as
follows:
➢ PALISADE T" attached to deck per FRSA/TRI 07320/8-05 requirements followed by cap
layer of Tamko TW Metal and Tile Underlayment, GAF UnderRoof 2 Tile Underlayment or
CertainTeed Flintlastic SA Cap.
Exterior Research and Design, LLC. Evaluation Report 519010.07.09-111
Certificate ofAuthorization#9503 FL5325-R5
Revision 1: 04/22/2012
Page 3 of 6
RINI
5.1.6.2 For System 4A, Option 5 and System 413, Option 4, approved underlayment systems are as
follows:
PALISADE T" attached to deck per FRSA/TRI 07320/8-05 requirements followed by cap
layer of GAF UnderRoof 2 Tile Underlayment or CertainTeed Flintlastic SA Cap.
5.2 For HVHZ Jurisdictions:
5.2.1 PALISADE TM SA-HT is not for use in HVHZ.
5.2.2 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing
Materials Directory for fire ratings of this product.
5.2.3 This Evaluation is for prepared roofing applications. Minimum deck requirements shall be
compliant with applicable FBC sections.
5.2.4 PALISADE TM shall not be applied in hot asphalt.
5.2.5 PALISADE TM
shall be installed in strict compliance with the requirements for ASTM D226, Type
II or ASTM D2626 underlayment in Section 1518 for the type of prepared roof covering to be
installed.
5.2.6 PALISADE TM may be used with asphalt shingles, tile roofs (See 5.2.6.1), non-structural metal
roofing/ metal shingles, quarry slate, slate-type shingles and wood shakes &shingles.
5.2.6.1 For tile roof applications, PALISADE T" shall be mechanically attached as an anchor sheet in
accordance with RAS 118, RAS 119 or RAS 120 and Section 6 herein, followed by Tamko TW
Metal and Tile Underlayment.
5.2.6.2 The above noted cap underlayment membrane (Tamko TW Metal and Tile Underlayment) shall
hold HVHZ Product Approval and/or Miami-Dade NOA as an underlayment for use in tile roof
systems.
5.2.7 If PALISADE TM is not specifically listed in the prepared roof covering NOA, this report may be
submitted to the AHJ or Miami-Dade Product Control Dept., along with fire classification
information, for their consideration.
5.2.8 PALISADE TM underlayment shall not be left exposed for longer than 180-days after installation.
5.3 All products listed herein shall have quality assurance audit in accordance with F.A.C. Rule 9N-
3 requirements.
6.. INSTALLATION:
6.1 PALISADE T" Roof Underlayments shall be installed in accordance with SDP published
installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re-fasten any loose decking panels, and check .for protruding. nail heads. Sweep .the
substrate thoroughly to remove any dust and debris prior to application, and prime the
substrate with Elastocol Stick.
6.3 For Non-HVHZ Jurisdictions:
6.3.1 PALISADE TM:
6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II'or ASTM
D2626 underlayment in FBC Sections 1507 for the type of prepared roof covering to be
installed.
6.3.1.2 For non-tile applications:
Exterior Research and Design, LLC. Evaluation Report S19010.07.09-111
Certificate of Authorization#9503 FL5325-R5
Revision 1: 04/22/2012
Page 4 of 6
X.
TRINITY ERD
PALISADETM is installed horizontally with the printed side up, and with 3-inch horizontal laps
and 6-inch vertical laps. Overlaps must run with the flow of the water in a shingle pattern.
The underlayment is only attached to the roof deck with roofing nails (smooth or ring-
shanked) having 1-inch minimum diameter plastic or steel caps compliant with FBC
1507.2.6. Cap nails are spaced at 6 inches on center at vertical laps, and at 11 inches on
center at horizontal laps. In the field area, apply fasteners at 13 inches spaced vertically and
22 inches on center horizontally. All caps (including nails) must be fully flush with the
underlayment surface. Do not install fasteners over unsupported areas/voids. Repair all
tears, holes, or damage to the underlayment. For slopes less than 4:12, use a full 20" half
lap over the underlying course. Apply underlayment up all abutments at least 6 inches.
In non-HVHZ high wind regions where V„it > 181 mph (Vasd > 140 mph) or exposure beyond
30 days, increase the fastener density to cap nails spaced 3 inches on center at vertical laps,
and at 5.5 inches on center at horizontal laps. In the field area, apply fasteners at 6.5 inches
spaced vertically and 11 inches on center horizontally. In addition, secure laps by folding all
laps over before nailing, or taping securely across lap seams using exterior grade sheathing
tape, or sealants such as roofing cement (asbestos free meeting ASTMD4586), EPDM or butyl
to seal laps.
6.3.1.3 For tile applications:
Fastening of PALISADE TM in tile applications per Table 2 herein should be proportionate to
that outlined in FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, taking into account
the wider sheet width. Tile shall be loaded and staged in a manner that prevents tile
slippage and/or damage to the underlayment.
6.3.2 PALISADE SA-HT TM:
6.3.2.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC
Sections 1507 for the type of prepared roof covering to be installed.
6.3.2.2 The installer is responsible to determine whether priming is required to ensure PALISADE TM
SA-HT will stay adhered to the substrate.
6.3.2.3 For non-tile applications:
PALISADE SA-HTTM is installed horizontally with the printed side up, and with 3-inch
horizontal laps and 6-inch vertical laps. Starting at the low point, and with salvage edge at
the high point, position horizontally a full roll or cut the membrane into 10-15 ft. (3-5m)
lengths and re-roll loosely. Peel back 1-2 ft. (300-600mm) of release film, align .the
membrane, and continue to peel the release film from the membrane. Press the membrane
in place with heavy hand pressure. Apply uniform pressure to the membrane roll side and
end laps to insure water tightness and bonding to the substrate.
Always work from the low to the high point of the roof. Follow good roofing practice by
orientating PALISADE-SA-HT TM so side laps shed water. Apply the membrane in valleys
before the membrane is applied to the eaves. For valley and ridge application, peel the
release film; center the sheet overthe valley or ridge, drape, and press into Jn place. Work
the center of the valley or ridge.outward in.each direction.. Following.placement along.the
eaves, continue application of the membrane up slope. If nailing of the membrane is
necessary on steep slopes, especially during hot or cold weather,back nail and cover the
nails by overlapping with the.next.sheet.
Exterior Research and Design,LLC. Evaluation Report 519010.07.09-Ri
Certificate ofAuthorization#9503 FL5325-R5
Revision 1: 04/22/2012
Page 5 of 6
TRL�IIIY
6.4 For HVHZ Jurisdictions:
6.4.1. Approved Assemblies:
6.4.1.1 System E(1): Underlayment mechanically fastened to deck
Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32"plywood or wood plank
Underlayment: One or more plies of PALISADE TM with minimum 4"wide head laps and
minimum 6"wide end laps, mechanically fastened to deck.
Fastening: HVHZ Approved nails and tin caps 6" o.c. at lap and three equally
spaced staggered rows 12"o.c. in the field.
Surfacing: HVHZ Approved asphalt shingle, non-structural metal, wood shakes & .
shingles or slate.
6.4.1.2 System E(2): Base underlayment mechanically fastened to deck, top layer adhered
Deck Type 1: Wood, Non-Insulated
Deck Description: Min. 19/32"plywood or wood plank
Base Layer: One or more plies of PALISADE TM with minimum 4"wide head laps and
minimum 6"wide end laps, mechanically fastened to deck.
Fastening: HVHZ Approved nails and tin caps 6" o.c. at lap and three equally
spaced staggered rows 12"o.c. in the field.
Top Layer: Tamko TW Metal and Tile Underlayment, self-adhered to the base
layer with minimum 3"head laps and minimum 6"staggered end laps.
Surfacing: HVHZ Approved asphalt shingle, non-structural metal, wood shakes &
shingles, slate or tile.
Note: For tile applications, AH] shall verify that top layer underlayments
listed herein hold current HVHZ Product Approval and/or Miami-Dade
NOA for use as a tile underlayment.
7. LABELING:
Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the
Accredited Quality Assurance Agency noted herein.
S. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
9. MANUFACTURING•.PLANTS:
Contact the manufacturer or the named QA entity for information on plants covered under Rule 9N-3
QA requirements.
10. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc. - ETL/Warnock Hersey - QUA1673
(905) 678-4913
- END OF EVALUATION REPORT-
Exterior Research and Design, LLC. Evaluation Report S19010.07.09-111
Certificate of Authorization#9503 FL5325-R5
Revision 1: 04/22/2012