Loading...
HomeMy WebLinkAboutProduct Approval Florida Buildingo 0 a Code ItAptiti`�loridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtgkcMGbIcW71/o2fZr7gdugvK/o2byVUTv851uE/o3d 3, :•,t',°:':,a ';�.i': SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats R Facts Publications FBC Staff DCIS Site Map Links Search Business,( Professional USEApproval uses:renuc user R 1uiatit;(1 t?auilurinLApAl+raLnnSe,1ch>fWAbr Atuu�li.st>Application Detail FL u FL9777 R3 �71"�` - Application Type Pp yP Revision Code Version 2010 Application Status Approved Comments Arc hived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 03/08/2015 Validated By Locke Bowden Validation Checklist- Hardcopy Received Certificate of Independence CLr17 tion ReporL2plp_gHC_1,VeathLrLock 050714-pdf Referenced Standard and Year(of Standard) • erandatd Year ASTM D 1970 2001 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 05/06/2014 Date Validated 05/08/2014 Date Pending FBC Approval 05/08/2014 Date Approved 06/23/2014 Page 1 of 2 Florida Building CodetMpirWoridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvK%2byVUTv85luE%3d Summary of Products— FL* Model,Number or Name 1 Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No EL9777 o-t If nrnte002-Evahyy Approved for use outside HVHZ:Yes SMeatherI nrk n5D714-pdf Impact Resistant:N/A Verified By: Zachary R, Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FI 11777 p7 AF CICRIA00?Fvahlatjptyg I:L2010-EBC utteatheth ack Q503311 pill Created by Independent Third Party: Yes 9777.2 Weatherlock MAT i Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No Pi()7- _ k:a Approved for use outside HVHZ:Yes 1Neatllexto,L,ncn�7ld prf1 Impact Resistant:N/A Verified By: Zachary R. Priest 74021 I Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports f FI Q777—R7�AE�ICI�IAj�02_EUdlUatjOil i'pOrt.-101Q_EVC _ i i J Created by Independent Third Party:Yes 9777.3 Weatherlock Specialty Tile&Metal Weatherproofing Underlayment ...... - _ . _ - _.. .......... . ........-- Limits of Use Installation Instructions Approved for use in HVHZ:No EL9777_R3 U=OCR1a002-Evaluatioa-Repatt-7010 EBC Approved for use outside HVHZ:Yes Weather'ock-050714_p4f Impact Resistant:N/A ; Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. i Evaluation Reports _ port.2010 FD tdteatherinck-OSQ71si.pdf Created by Independent Third Party: Yes r'nnrwrr Its;;t4an rFn th M n Cl c.,t,7 1! h FI i�'1ntJ phnan�ACn-dA7-rA�A The State of Florida is an WEED employer.Cnpydpdvvy Statement::A,,ce aJhriay cjatCjnjwA::Betund CtatmmCnt Under Florida law,email addresses are public records.It you do not want your a-mall address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall,If you have any questions,please contact 850.487,1395.'Pursuant to Section 455,275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The email&provided may be used for official communication with the licensee.However email addresses are public record.If you do net wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 45S,F.S.,please click hem. Product Approval Accepts: pRifJ � M.PeAi M ,m wit•yet llgt'� Page 2 of 2 Certificate of Authorization No. 29824 Drive 17520 Edinburgh Drive Tampa,FL 33647 i TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2010 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued May 7, 2014 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 www.owenscorning.com Manufacturing Location: Brentwood, NH Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.4,1507.2.9.2, 1507.3.3, 1507.5.3 Properties: Physical properties REFERENCES 9fl2ty Reoort No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) NEI.042-02-01 REV2 ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI.053.02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2001 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock}G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockQ G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles,and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLockOD Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq,rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.roils with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles,and state roofing as prescribed in the FBC. Exposure on the roof.deck shall be limited to a maximum 30 days. WeatherLock@ WeatherLock@ Specialty is an ASTM D 1970 self-adhesive underlayment constructed Specialty Tile&Metal from SBS modified asphalt and surfaced with a non-woven polyester fabric. The product is supplied in 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. roils with nominal dimensions of 3-ft x 71.3-ft. OCR14002 FL9777-R3 Page i or 3 This evaluation report is provided for State of Florida product approval under Rule 9N-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. ` CREEK OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC WeatherLock@ WeatherLock@ Specialty Tile&Metal is permitted to be used with mechanically fastened Specialty Tile&Metal asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or (continued) shingles, and slate roofing as prescribed in the FBC. WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM 2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BOND TM Roof Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of-45 psf and in accordance with the system approval. Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete the installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater than 10 tiles per stack. PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with FBC Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed direct-to-plywood decking with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum 6"staggered end laps. End laps for WeatherLock@ Specialty Tile& Metal shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). WeatherLock@ Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, the underlayment should extend to a point 24-inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave,and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14001 FL9777-R3 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock@)Self-Seating Ice&Water Barriers TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein have demonstrated compliance with the 2010 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. I I I R. E N .`�'����P�G &"Z No 74021 2014.05.07 STATE OFui: { .....,_ 20:18:15-04'00' A' 4 0 RZachary R,Priest,P.E. %% Florida Registration No.74021 %,`i%. Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products Linder this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest.P.E,does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation, Zachary R.Priest.P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCRI4001 FL9777-R3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. ' Flog ida Building Code Online Page 1 of 2 �i tll J i, (.ka 'ICI SCIS Home `: Log In ". User Registration (Hot Topics ;Submit Surcharge (Stats Facts i Pubii atians 3 FBC Staff #aCiS Site Map ;Links i Search i Bushes �( ? Professional USER: uc c User Approval Regulation Product Approval Menu>Product or AaaHcation Search>app ication List>Application Detail I <• FL# FL10674-RB Application Type `,,,,.._Revision Code Version (f::Ap�proved Application Status Comments ((( Archived 0 Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Par way Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler I greg.keeler@owenscom ing.com i { Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo,OH 43659 (419)376-8360 mel.sancrant@owensco nig.com Quality Assurance Representative Address/Phone/Emall CategoryRoofing Subcategory Asphalt Shingl s Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report Hardcopy Received Florida Engineer or Architect Name who Robert J.M. Nieminen 3 developed the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 09/26/2014 Validated By John W.Knezevich,PE! 0 Validation Checklist-Hardcopy Received Certificate of Independence FL10674 R8 COI Trinit#py ERD CI-Nieminen pdf Referenced Standard and Year(of Standard) Standard Year ASTM D3161,Class F 2006 ASTM D3462 2007 ASTM D7158,Class H 2007 Equivalence of Product Standards Certified By http://tloridabuilding.org/pr/pr_app_dtl.aspx?param=-VvGEVXQw-tDgtBNbEY5 V°/a2boQT... 6/19/2013 Florida Building Code Online Page 2 of 2 ppi Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/19/2012 Date Validated 12/20/2012 Date Pending FBC Approval 12/25/2012 Date Approved 02/04/2013_ Summary of Products 171.# 1Model,Number or Name Description 10674.1 Owens Corning Asphalt Rooflng 3-tab, laminated,starter,and hip&ridge IShingles and Starters I Limits of Use Installation Instructions Approved for use in HVHZ:No FL10674 R8 h erI21912FINAL OC Asphalt Approved for use outside HVHZ:Yes Shingles_FL10674-R8.pd Impact Resistant:N/A Verifled By: Fk6bert J.M.Nlemlnen PE-59166 Design Pressure:N/A Created by Inopendent Third Party:Yes Other:Refer to ER, Section 5. Evaluation Reports FL10674 R8 AE ei-121912FINAL OC Asphalt Shingles FL10674-R8.pd Created by Independent Third Party: Yes Back Next Contact Us 1940 North Monroe Street,Taiiahassee FL 32399 Phone:$50-467-16,24 The State of Florida is an AA/EEO employer.Copyright 2007-2010 state of Florida.;;Privacy Statement::Accessibility Statement Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail addressireleased in response to a public-records request,do not send electronic mail to this entity,instead,contact the office by phone or by traditional mail.It you have any questions,please contact 850.487.1395. .Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee,However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with anj email address which can be made available to the public. To determine if you are a licensee under Chapter 455,F.S,,please click here. Product Approval Accepts: Qj ig � http://floridabuilding.orc-,/nr/l)r app dtl.aspx?param==NNGEVXQwtDqtBNbEY5V%2boQT... 6/19/2013 Assurance documentation changes. Th ity| RD requires a comoete review of this Evaluation TRIN11'IERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, asproduced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein, 2. STANDARDS: Section Proft Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7,1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007 3. REFERENCES: Entity Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol,. 3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012 Miami-Dade(CER1592) FBC HVHZ Compliance 07-1116.12 02/14/2008 Miami-Dade(CER1592) FSC HVHZ Compliance 09-0915.12 12/16/2009 Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.09 10/27/2010 Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.10 10/27/2010 Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.08 10/27/2010 Miami-Dade(CER1592) FBC HVHZ Compliance 10-0817.07 10/27/2010 Miami-Dade(CER1592) FBC HVHZ Compliance 11-0411.03 j 06/16/2011 Miami-Dade (CER1592) FBC HVHZ Compliance 12-0309.01 07/19/2012 UL LLC (QUA9625) Quality Control Service Confirmation R2453 Exp. 09/26/2014 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classico and SupremeO are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 BerkshireOp are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Duration, TruDefinitiona Duration, Duration's' Premiut i�i Cool, Trul)efinitlon'�' Duration Designer Color Collection, TruDefinitio0' Oakridge`, Oakridges and Weathei­Guard� HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuarda HP Hip & Ridge Shingles and ProEdge Hip & Ridge Shingles are 'fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Plus and Star-ter Shingle Poll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: Exterior Research and Design, LLC. lEvaluation Report 037940.02.12-R2 Certificate of Authorization#9503 FL10674-RS Revision 2: 12/19/2012 Page 2 of 6 . . | \^ / ���� ' �� K �^��� o n )��^�' 53.1 All Owens Corning shingles noted herein are Classified lin accordance with FBC Tables 1507.2.7,1 and R905.2.6.1 to ASTM D3161, Class F and/or:ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to V,sd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this Wind rating. 5.3.2 All Owens Corning hip & ridge shingles and Starter Strip accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to V,,d =1150 mph (Vult = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM o7158 applies to exposure category feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data:specific to each shingle. 5.3.4 Refer tnOwens Corning published information onwind resistance and installation limitations. 5.4 All products in the roof assembly shall have quality assoronce audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. | 6. INSTALLATION: 6.1 UndenUmymmmmt, | 6.1.1 Undadayrnentsha{| beacceptable toOwens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9IN'3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 5.2.1 Installation of asphalt shingles shall comply with the current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2with the following excep > Berkshire@ shingles require minimum five (5) nails per'shingle. > WeatherGuardO HP shingles require minimum six (6) nails per shingle. Starter Strip Plus requires minimum five (5) nails per strip. Refer to Owens Corning published information on wind resisItance and installation limitations. 6.2.2 Fasteners shall be in accordancewith the manufacturer's less than FBC 1507.2.6 or R905.2.5. Staples are not permitted.i 6.2.4 Where the of slope exceeds21 units vertical in 12 units horizontal, speci | methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing - Oassic@ &Supreme; 2. vim Expoofcf4n :=.I 6. 117 Exterior Research and Design,LLC. Evaluation Report 037940.02-12-112 ce,timam°uvu"thoazamon#eswa pL10674-mS Revision 2: 12/1e/2012 Page 3mfa \,J\TRINITY IERD 6.2.6 Minimum Nailing - Berkshire@: S,Qbd Strip 'I LA tka s"w to th gnsdar RYf9 Vf 9 V a W. ew 8 Yf Bk' 8 1pf r 6.2.7 Minimum Nailing Duration& TruDefinition@ Duration, Duration@ Premium Cool & TruDefinition� Duration3 Designer Color Collection: 4 N23 Pattern E Not Etipoma do 4 davos Pattern OW'q'O.t.'c li 6 U OPI,lird d=IS4U=Ik-n 653d'% 14— AWN r asm ftwb kum 1 LE --04 -P.-r-z-2. �q 57'.Ettpasvae Nab E21POSUM ---y-- 54"*EXP&AVO 5ap;dg.da exposa-ifin Clams 5q PU'V.do t1pasfef(in 6.2.8 Minimum Nailing —TruDefinition3 Oakridge@, Oakridge@: 4 MAI Pawn 9 Nall Partam Euluarm om 4 da es Esquwna cart b clavas r Nags ErpoddmdeSGlCpldg Nab Expownr CaratCbvos 5618 Etposuvr Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R2 Certificate of Authorization#9503 FI-10674-RS Revision 2: 12/19/2012 Page 4 of 6 | � . / / �FTRINITY ��� IERD 6.2.9Minimum Nailing - VVeadherGuand@ UP: NOW 6.3 Hip & Ridge Shingles: 6.3.1 Installation of BerkshireOHipd Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuardO HP Hip and Ridge Shingles and ProEdge Hip�t Ridge Shingles shall comply with the manufacturer's current published instructions, using fol r (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand-sealing for wind warranties. 6.3.2 Fasteners shall be |naccordance with the manufacturer's p bUahed requirements, but not less than FBClSO7.2.6orR9OS.2.S. Staples are not permitted. | � 6.3.3 Minimum Nailing - 8erkshine@ Hip&Ridge and High Ridge' A- PruvAWOV'And Medion Hads Rme 6,3.4 Minimum Nailing - Hip &Ridge with Sealant: im Shingle, Excew 210 2" 2" Y2� Sealant /* 5"Exposuve Distance / 12 / Exterior Research and Design,LLC. Evaluation Report 0379*0.02,12-R2 Certificate"fAuth*x*zation#ns0s rL10674-eo Revision 2: 12/1e/2012 Page 5mv6 , ^ i � | \' / TRINITYERD ' . 6.3.5 Minimum Nailing — WeatherGuard@ HP Hip and Ridge: Fig.A Fig.C Hip&Ridge Shingle Fastening waits 6.3.6 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Standard Fastening Wind Direction seb.,Strfp Pattern Fatten 7V 71h. S'Expasu I Fasteners with Cow Expand Roo rAntant 7. LABELING: � 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, dty, state and logo ofthe Accredited Quality Assurance Agency noted herein. / 7.2 Asphalt shingle wrappers shall indicate compliance with nu of the required classifications detailed in FBCTab|e 1507.2.7.1 / R905.2.6.1. | S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Junsdictio h in order to property evaluate the installation ofthis product. 9. MANUFACTURING PLANTS: / Contact the named OAentity for information onwhich plants produce products covered by Florida Rule 90'3 QA requirements. 10. QUALITY ASSURANCE ENTITY: ULLLC- gU&9625 (414) 248-6409; - END OF EVALUATION REPORT Exterior Research and Design, LLC. ,Evaluation Report 037940.02.12'R2 ce,mmcauew*uvu*nmzauvn#9503 | FL10674-118 ! Revision 2: 12/1e/2012 Page swre /