Loading...
HomeMy WebLinkAboutProduct Approval F ` WJ E N E R AC 16/20/22 k o�ECl'.'�� �u� 2 3 zoo GUARDIAN® SERIES'ST. COV W"x`40 D"'&sidential Standby Generators MM FOR CO TPL Air-Cooled Gas Engine O By--3 in i It® INCLUDES: OR NO INSPECIION NVILL BE MADE. Standby Power Rating • True Power'" Electrical Technology Models 006459-0, 006461-0, 006462-0 (Steel- Bisque) - 16 kW 60 Hz • Two Line LCD Multilingual Digital aef_00672T0—(Altaminum_�Gray16-k1�V60�(z: Evolution" Controller (English/Spanish/ Models 006729-0, 006730-0 (Steel -Bisque) -20 kW 60 Hz French/Portuguese) Models 006551-0, 006552-0 (Aluminum- Gray) -22 kVV 60 Hz • Two Transfer Switch Options Available: 100 Amp Pre-Wired Switch or 200 Amp Smart Switch. See Page 4 for Details. K ". • Electronic Governor ` • External Main Circuit Breaker, System Status & �� �,• *^' Maintenance Interval LED Indicators • GFCI Duplex Outlet GENERIC a • Sound Attenuated Enclosure s • Flexible Fuel Line Connector • Composite Mounting Pad • Natural Gas or LP Gas Operation C&S • 5 Year Limited Warranty LISTED QUI • Capability to be installed within 18" (457 mm) Note:CUL certification only applies to unbundled units and units packaged with pre-wired switches. of a building* Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors,windows and fresh air intakes,and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN&PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing,reliability all Generac models. It provides optimized FAST RESPONSE to changing testing,environmental testing,destruction and life testing,plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA,NEMA,EGSA,and other standards,allows you to electronically torque-matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at ±1%. systems will provide superior performance. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit,from the utility quality power.This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro-chip based appliances,such as variable speed HVAC systems. O GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this * PROTOTYPE TESTED NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® GENERAC® CM 16/20/22 kW features and benefits 04 Engine •Generac(OHVI)design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler,reducing oil consumption resulting in longer engine life. • Quiet-Test" Greatly reduces sound output and fuel consumption during bi-weekly exercise,compared to other brands. •"Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. of •Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. •Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. •High temperature shutdown Prevents damage due to overheating. Generator •Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. •Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. •Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. •UL 2200 listed For your safety. Transfer Switch •Fully automatic Transfers your vital electrical loads to the energized source of power. •Pre-wired,color-coded conduits Ensures the easiest,trouble-free installation. (Pre-wired switches only) •DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. -Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution"' Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. •Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. -Sealed,raised buttons Smooth,weather-resistant.user interface for programming and operations. •Utility voltage sensing Constantly monitors utility voltage,setpoints 60%dropout,80%pick-up,of standard voltage. •Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. •Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. •Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. •Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. •Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. -Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. •Electronic governor Maintains constant 60 Hz frequency. Unit •SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items.Electrostatically applied textured epoxy paint for added durability. •Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. -Small,compact,attractive Makes for an easy,eye appealing installation,as close as 18"away from a building.` Installation System •1 ft(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. -Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities. GENERAC® 16/20/22 kW specifications Generator 006459-0,006461.0,006462- 006729-0,006730-0, 006551.0,006552-0 _ Model 0 006721 0(16 kW) (20 kW) (22 kW) Rated Maximum Cdnlin o s'Povier Ca act CP) r .- 'h MR. ,t � � ,�_X­ Rated _ �nu16:000,Watts 20 000'Watts'' ��22 000 Watfs,'� Rated Maximum Continuous Power Capacity(NG) 16,000 Watts*4 18,000 Watts* 19,500 Watts* - uua=vvuS Ydi.,.�,,,,,,.�_ .-. .•- uuSu.!'.vv.•.v�u L'i�, ..4—..I>i::�,+�..,._.1,WacG_�..w,,.;l Rated Maximum Continuous Load Current—240 Volts(LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total:HarmdniclDistdrlion � tha essthan5°/1 o! r Lesstflan5% Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp .. 1 Phase 3 v „ * r. : xz 1 Number of Rotor Poles 2 2 2 Rated AC._IJ ".;'160 Hz ->,.s.�..-•........,..,..,,.- h ...............-...- Power Factor 1.0 1.0 1.0 Badery Re jblreme"of jnot included) _s yG, _._ _ -_ * M„Group 26R 12;Volts and 525.CCA;Miritmum,._msµ _ .__1__ _ 513/232.7(Steel); 516/234.1 526/238.6 Unit Weight(Ib/kg) 448/203.2(Aluminum) 25 xi29/1218 x'638 x 732 f- Sound output in dB(A)at 23 it(7 m)with generator operating at normal load** 66 66 67 Sound output m d8(A)at 23 it(7 m)with generator'in OweC=Test low speed Exercise duration 5 min ......_._�,.__,_....._._.._.__5 min ��_•J 5 minj_lµ -t Engine pe df Engine _ ___,� �'' „_”� GENERACOHVI VTWIN__ GENERAL OHVI V'TWIN GENERAL OHVI VTWIN Number of Cylinders 2 2 2 IDi�lace'rnent, � ,.Iq � �---T992cc �'�'. 999cc1, �, 999 cc ' Cylinder Block Aluminum w/Cast Iron Sleeve VaIVe A�iarigement t yF _�a" c_iOGerfleotlrValvel `kOVerhead.Ualve 'OGerhead Valye�_ lam) Ignition System _ Solid-state w/Magneto W Solid-state w/Magneto Solid-state w%Magneto Governor S stem -s -� - �e J e y_ E c_Uomc Elecironic�.� Compression Ratio 9.5:1 9.5:1 9.5:1 Oil Capacity Including Filter Approx.1.9 gV1.8 L Approx.1.9 g1/1.8 L Approx.1.9 gV11..8 L Operdtingarpro �_. ._ i_ 3 600 �'� Fuel Consumption Natural Gas ita/hr(m3/hr) 1/2 Load 193(5.47) 205(5.8) 184(5.21) Full Load 312(8.83) 308(8.12) 281(7.96) Liquid Propane ft3/hr(gal/hr)[I/hr] 1/2 Load 72.4(1.99)[7.53] 75.6(2.08)[7.87] 83(2.16)[8.16] Full Load 130(3.57)[13.53] 140(3.85)[14.57] 127(3.68)[13.99] r_Note Fuel pipe must he sued for:(ull load Rl:qurred fuel pressure to generator fuellnlet at all Ieadranges 3;5=.7 water column(7 13 min mercury)i&r natufafgas 10 12,Water column(19 22 mm mercury)farLP gas:Fal Btu conteotr multiply"ft3/fif z 2500(LPj.or ft3/hr,X"1000(NG)i F.of Megajodli!corllent, ultiply man -x'8315(LP]orma/hr x 37;26 , Controls 42 Line PlatLr Text Multilitlgual,LC,D'Display y]w T Sim le usernte ace fol ease_of Mode Buttons: Auto Automatic Start on Utility failure.7 day exerciser. Manual �� ?: _ -- St$rt Willi startei'do itiotNt tays'on If utilitylfarlstransfeao load lakelace u] Off Stops unit.Power is removed.Control and charger still operate. Ready to.RuNMamte once Messages•: y .; Standardyk Engine Run Hours Indication Standard �Piograrnmatile start tlelay;betvieen 2-1500 seconds' ,+ " .Wne,� .y, ,�Wu �� ,,,,Standard(progr_ammable tiydealer only) Utility Voltage Loss/Return to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V ;'Future SeCCapable Exerciser/Eicereise_Set Error,Wam`Ihg .' lnrT z Standard :.,�Wy�� Run/Alarm/Maintenance Logs 50 Events Each Engine Start:Sequence r`_�., k �; W ,;;;_:.y...„ :Cyck¢�crahking,i6 secion 7 re_st_(90 sec maximum duration).,, -y,_,,_,_ _;- ..._...._._.,mow-.... —...___ Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Batte Char er _ Standard Charger FaulVMissing AC Warning Standard Low Ba(Eery(Batlery:Pioblem Proteot(oo and Bolter C,onditidi!ln icahoN, '- T,r,. ...,.._ aSl palord,,l_ Automatic Voltage Regulation with Over and Under Voltage Protection Standard :;Under Fre uenc/OveifdaiUSte,er OvercurrentP,rotechon ,. Standard ^' r q__Y PP .WL.Wim_ Safety Fused/Fuse Problem Protection Standard _ uto at d:Low Od Pressure/�F(gli Oil:TemperatureSfrutdown v i tandardi ” Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdown Standard --: .H]9h�9ineTerriperature,�SllutdoWn .ar�S `��' „�„�' Internal FaulVlncorrect Wiring Protection Standard _ i 'Co mon F�dernal Fauit•,Capability Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator.Sound levels taken from other sides of the generator may be higher depending on installation parameters.Rating definitions-Standby:Applicable for supplying emergency power for the duration of the utility power outage.No overload capability is available for this rating.(All ratings in accordance with BS5514,IS03046 and DIN6271).*Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature,altitude,engine power and condition,etc.Maximum power decreases about 3.5 percent for each 1,000 feet(304.8 meters)above sea level;and also will decrease about 1 percent for each 6 T(10 T)above 16'C(60 19. GENERAC® 16/20/22 kW switch options Pre-wired Features Model 006461-0(16 kw) available on Steel 16 kW models only �No of Poles:- ;12 _ • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps) 100 connections. Votage Rating(VAC) _�r' �—Md 20/240 1H ;;y „ ' Utility Voltage Monitor(Fixed)* • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% resistive. -Dropout 60% • 2 ole,250 VAC contactors. 'Return[o'tJtihty _ , _,_„�, ,__v.,,,-u-__,,-._...-__._,epproz 15,sec P Exercise weekly for 12 mmutes� Standard • 30 millisecond transfer time. llL Listed: Standard 1 Total of Pre-wired Circuits 16 • Dual Coll design. No.15 A 120 V 5 No.20 A 120 V 5 • Main contacts are silver plated or silver alloy to resist welding and sticking. No.20 A 240 V 1 • NEMA 1 (indoor rated)enclosure is standard on the pre-wired switch. No.30 A 240 V - No.40 A 240 V 1 • Pre-wired 30 foot(9.1 meter)whip to connect to the provided 5 foot pre No 50 A 240 V 1 wired whip and external connection box. Cncwt breaker Protecterl Available RM&Symmetncal • Pre-wired 2 foot(0.61 meter)whip,color coded to connect into the tFault.current @ 25o Volts 10 000.�_ ______wj existing electrical panel. `- _. *Function of Evolution Controller Dimensions Mechanical Dimensions a L Height Width Depth = H1 H2 W1 W2 H2 H1 in 23.5 26.4 8.3 12.6 63 mm 597 671.7 211 320.7 159.6 Wire Ranges J C . Conductor Lug Neutral Lug Ground Lug -— I 2/0-#14 2/0-#14 2/0-#14 F— 2— Smart Switch Features Model 006462-0(16 kW)/006729-0(20 kW)/006551-0(22 kW) • Includes Digital Power Management Technology standard(DPM). N_006 les Current Rating(Amps) 200 • Intelligently manages two air conditioner loads with no additional voltam ge.,`Rahng;;(vAc) -,- hardware. Utility voltage Monitor(Fixed)* • Up to four more large(120/240 VAC) loads can be managed when -Pick-up 80% used in conjunction with Power Management Modules(PMM**). Dropout 60% 5— TOT ty '� approx 13 sec:` • Electrically operated,mechanically-held contacts for fast,clean Exercise weekly for 12 minutes* Standard connections. Enclosure Type NEMA/UL 3R • Rated for all classes of load,100%equipment rated,both inductive tWithstand Rating_(Amp: 000" and resistive. Lug Range 250 M _#6 • 2 pole,250 VAC contactors. *Function of Evolution Controller • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 3R aluminum outdoor enclosure. "'1 v • Main contacts are silver plated or silver alloy to resist welding and sticking. **Note:PMM starter kit is required prior to using the modules. H2 H1 Dimensions 200 Amps 120/240,1e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 kMmin 27.24 30.0 11.4 13.5 7.09 692.0 762.4 289.0 343.0 1 180.0 L DEPTH ,it , r • GENERAC® 16/20/22 kW available accessories Model#, product " 7 Descr'iptlan# Generac's Mobile Link allows you to check the status of your generator from anywhere that you have 006463-1 Mobile Link'" access to an Internet connection from a PC or with any smart device.You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). If the temperature regularly falls below 32°F(0°C),a cold weather kit is required to maintain optimal 006212-0 Cold Weather Kit battery and oil temperatures.Kit consists of a battery warmer and oil filter heater with built-in thermostats. 005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical Kit load you may not need.Not compatible with 50 amp pre-wired switches. 005839-0-Bisque Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers 005666-0-Gray (Standard on 22 kW) a sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0-Bisque If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect 005704-0-Gray Paint Kit* from future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0-16 kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete i 006485-0-20&22 kW routine maintenance on a Generac automatic standby generator. J Completely wireless and battery powered,Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house.Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24 VAC,field installed transformer that enables the use of the 24 006199-0 PMM Starter Kit VAC Power Management Modules(PMMs)and one PMM.The standard controller(without starter kit) can control two HVAC loads with no additional hardware.Not compatible with pre-wired switches. Power Management Module(50 Power Management Modules are used in conjunction with the Smart Switch to increase its power 006186-0 Amps) management capabilities.It gives the Smart Switch additional power management flexibility not found in any other transfer switch.Not compatible with pre-wired switches.Note:PMM Starter Kit required. J *Note:Bisque kits are used in conjunction with steel enclosures.Gray kits are used in conjunction with aluminum enclosures. dimensions & UPCs Dimensions shown are approximate.Refer to installation manual for exact dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637.6 mm 121mm [25.1 in] [47.9 1n] Model UP L 006459-0 696471064599 o ( 0064610 696471064612 p: 006721-0 696471067217 731.9!n ! 1, - [ze.B in] = 006729-0 696471067293 006730 0 696471067309 006551-0 696471065510 o o -- °i 006552-0 696471065527 006462-0 696471064629 542 mm [25.3 in] 1226 mm [48.3 in] LEFT SIDE VIEW FRONT VIEW GENERAC® Generac Power Systems,Inc. • S45 W29290 HWY.59, Waukesha,WI 53189 • generac.com Elam ©2014 Generac Power Systems,Inc.All rights reserved.All specifications are subject to change without notice. Bulletin oK84511-0 Printed in U.S.A.06/19/14