Loading...
HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2 Florida l,Fyartnnent� BCIs Home ( Log In � user Registration � Hot Topics I Submit Surcharge { Stats&Facts Publications FBC Staff i SCIS Site Map } Links i Search ' Bus'pes PIrdfeSSii 0 Product Approval USER:Public user prndyrt Annmvat M nn> Saarrh>A=UCaLinn 1 ict>ApAIIGaUOA Detail FL# FL9777-R4 .a .k..v r Application Type Revision Code Version 2014 Application Status Approved g RECEIV D JUL 0 6 2M Comments A Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 CIO (740)404-7829 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Koofin Subcategory Underla pts Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ✓, Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Quality Assurance Contract Expiration Date K 12/31/2020 �1 Validated By a BovvUen Validation Checklist-Hardcopy Received Certificate of Independence FL9777 R4 COI OCR14002 1 FBC 2014 Evaluation Report 2010 FBC WeatherLock,odf Referenced Standard and Year(of Standard) Standard Yea ASTM D 1970 2009 Equivalence of Product Standards Certified By Sections from the Code https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXCWDgtgkcMGbIcW71%2fZr7gdugvKmDj6kDHt6tY%3d July 1,2015 Florida Building Code Online Page 2 of 2 Product Approval Method Method 1 Option D Date Submitted 02/23/2015 Date Validated 02/24/2015 Date Pending FBC Approval 03/01/2015 Date Approved 04/15/2015 Summa of Products FL# Model,Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R4 II OCR14002 1 FBC 2014 Evaluation Resort 2010 Approved for use outside HVHZ:Yes FBC WeatherLock.pdf Impact Resistant:N/A Verified By: Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party:Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R4 AE OCR14002 1 FBC 2014 Evaluation Report 7010 FBC WeatherLock gdf Created by Independent Third Party:Yes 9777.2 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R4 II QCR14002 1 FBC 2014 Evaluation Report 2010 Approved for use outside HVHZ:Yes FBC Weatherl-ock.odf Impact Resistant:N/A Verified By: Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R4 AE OCR14002.1 FBC 2014 Evaluation Report 2010 FBC WeatherLock.pdf Created by Independent Third Party:Yes 9777.3 WeatherLock Specialty Tile&Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ:No FL9777 R4 II OCR14002 1 FBC 2014 Evaluation Report 2010 Approved for use outside HVHZ:Yes FBC WeatherLock.Ddf Impact Resistant:N/A Verified By: Zachary R.Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R4 AE QCR14002 1 FBC 2014 Evaluation Report 2010 FBC WeatherLock pdf Created by Independent Third Party:Yes -E-Ei Next. Contact Us::1940 North Monroe Street..Tallahacs e FIL12199 Phnnea 85n-487-1874 The State of Florida is an AA/EEO employer.rof1v^ipht 7n47-7Q13 State of Florida;::Priva Statement::Acfe4sihiIIty Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S., please dick be=. Product Approval Accepts: In row E M securityntt:Ttttcv https://floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtgkcMGbicW71%2fZr7gdugvKmDj6kDHt6tY%3d July 1,2015 Certificate of Authorization No. 29824 CREEK 17620 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015 1 Owens Corning Parkway Toledo,OH 43657 (800)438-7465 www.owenscoming.com Manufacturing Location: Brentwood, NH Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2, Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-063-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq. -sq. rolls with nominal dimensions of 3-ft x 33.3 ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ WeatherLock@ Specialty is an ASTM D 1970 self-adhesive undedayment constructed Specialty Tile&Metal from SBS modified asphalt and surfaced with a non-woven polyester fabric. The product is supplied in 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. rolls with OCR14002.1 FL9777-R4 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. � �VYENGC�RN|��RDOFNGANDASPHALTLLC ��+0��D����'0�r / ��0������0�� WwathmMock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC nominal dimensions cf3~ftn71.3-ft. Wemt6mrLwck@ VVeetherLook@Specialty Tile&Metal iapermitted 0mbeused with mechanically fastened Specialty Tile&Metal asphalt shingles, clay orconcrete file, metal roof panels orshingles, wood shakes or (continued) shingles, and slate roofing as scdb d in the FBC WeatherLocw Specialty Tile Metal is permitted to be used with adhered clay concrete tile roofing using either 3N1''~ 2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BOND TM Roof Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of-45 psf and in accordance with the system approval. Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall bmstored onbattens for roof slopes greater than 8:12. Tl\oo shall not bestacked greater 1Otiles per stack. PRODUCT APPLICATION Min. Roof Slope: 2:12orinaccordance inwith FBC Application: A0 fasteners in the deck shall be checked for protr6sion and corrected prior to underlayment application. Prior to beginning installation, the underfayment shall be unrolled and allowed to relax for a minimum oF 3-5 minutes. The undmrlaymantahoU be installed decking with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum 6"staggered end laps. End laps for WeatherLock@ Specialty Tile& Metal shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the undmdoynm/n1 18-inchmson-center moneeded (nails shall be installed perpendicular to deck with the nail heads flush to the bop surface of the d . . VVeetherLonk@ Specialty Tile & Metal shall be book no(|ad when installed onroof slopes greater than 3:12. For valley applications, the nd| yho|| be applied centered along the valley prior to installing the unded ndudthooave. For eaveprotection, the undedoymentshould extend hoapoint 24-inuheoinside the exterior wall. The undedayment shall be installed over metal drip edge at the and underthe drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the d6p edge in accordance Section 1507.2.9.3. Min.Application 40^F; Contact the manufacturer when installing attemperatures below the minimum Temperature: application temperature. GENERALLIMITATIONS 1 This evaluation report isnot use inthe HVHZ. 2' Fire Classification isnot within the scope ofthis evaluation. 3inodaUeUonofthe evaluated product shoUcomply wdhthis nepo�.the FBO.and the mmn�o�un*rmpubUahod ' application instructions. Where discrepancies exist between these sourcesthe more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. ' The be used as described in other current FBC product approval documents. ! All pnoduda'i�edin ment 'ien*podoha]|bemonufactumdunderaqua|ityaeeurmnoepnogromlnoompUmncawidh Rule 61G20-3. of OWENS CORNING ROOFING AND ASPHALT LLC CREEK Weatherl-ock@ Self-Sealing Ice&Water Barriers TECHNICAL SERvicEs, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. % � N%0VC%J11111 R 111111,-#., % ....... A.- % e.- 2015.02.2 S 0 3 14:45:39 No 74021 r( ..,m.... —05'00' STATE OF 4(j N Zachary R. Priest, P.E. -- Ft Florida Registration No.74021 letIf## Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.1 FL9777-R4 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. I