HomeMy WebLinkAboutProduct Approval a
Florida Building Code Online t Page 1 of 2
Business/', ''
act$Home Log In ( User Registration Hol Topkt Submit Surcharge Stats R Fact,. Publitavons me staff WS she rtep Linke sca«h
Business!=,'
Professional 0,11 .)
USER PUGticcUUUserApproval
RECEIVEDU
�'r,L`f2 ?lfn{BYCt t_l+Ctg>$ts5 41LL6i.l�aDpCeso i est.3littlSSZ:iL'.CTl a A �tj mr Application Detail � t (�V 26
FL a Fuo674-Rio
Application Type =AvId
Code Version
Application Status
Comments
Archived P/4 tA**.
4tA**..
lcoProduct Manufacturer Owens Corning /
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keele r@owenscorning.com
Authorized Signature Greg Keeler
greg.keeter@owenscorning.com
Technical Representative Mei Sancrant
Address/Phone/Email i Owens Corning PKWY
Toledo,OH 43659
(419)376-8360
mcf.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Emait
Category Roofing
Subcategory C==Asphalt Shingles
Compliance Method Evaluation Report from a Fiorida Registered Architect or a Licensed Fiorida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert 3.M.Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity C7ll LG
Quality Assurance Contract Expiration Date 08/20/2017
Validated BypTin W Krtezevlch,PE
Validation Checklist-Hardcopy Received
Certificate of independence FL19 j74 R10 CCI 2015 01 Co1N0;trtnen.fadt
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
haps://floridabuilding.orgtpNpr app dti.aspx?param=wGEVXQwtOgtBNbEY5V%2boOT%2b6w7abRegICQ8ucR6lxEAulMeKNJKxMw%3d%3d July t.2015
Ftofida Building Codd Online Papp 2 of 2
Product Approval Method Method 1 Option D
Hate Submitted 04/22/2015
Date Validated 04/23/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Summary_of Products
FL# Model,Number or Name i Description
10674,1 Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge shingles
Shingles and Starters
limits of UseInstallation Instructions
Approved for use in HYHZ-.NoFy106,._.7�R_10 11 20 5. * F1NAt ER OC A5P—HALT
Approved for use outside HVHZ*Yes i1ltiS F1.19f>La�B�. isll
Impact Resistant:N/A i Verified By: Robert 3,M.Nieminen PE-59166
Design Pressure:N/A i Created by Independent Third Party:Yes
Other*Refer to ER,Section S. i Evaluation Reports
`*titMLES Fl.14671 l33 1.Dd1
Created by independent Third Party:Yes
rnntprt it, 194n Norih Ma, sit Wit.TAllnhasyt;t„fl,�,�s-4�t9�h[ut�.'HSf].AN I.1X�4
Ind.Stato of Florida is an ANEW employer,ro—i hr snny-Xnil Staten!flan. ;;pnvary_51��,�_r:;tyrrnsa�nnity etatmm�nt::[�,(enri_,,,,_e.,t�e,•:t
tinder nonda law,email addresses are public records.It you do not want your e-mad address released in response to a public-records request,do not sena eftctron,c
mail to this entity.Instead,contact the office by phone or by traditional mail,If you have any questions,please contact 050.497.1575.•p—.('ant to Section
'455.2'75(2),Florida Statutes,effective October 1,2oI2,licensees licensed under Chapter 455,F.S.must provide the Department with an emad addret5 if they N4
one,The emails provided may be used for official communication"fill the licensee.however email addresses are public record.It you do not ms?;to supply a personal
address,please pfovide the Department With an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,f.S.,
please click luap.
Product Approval Accepts:
''!r:i Q
� V't'11ri11'uF trf si.
https:flfloridabuilding.orgtpr/pr app_dtl.aspx?param=wGEVXQvvtDgtBNbEY5V%2boOT%2b6w7ahReglCQBucR6lxEAoiMeKNJKxMw°/aid%3d July t,2015
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate Of Authorization#9503
353 CHRISTIAN STREET,UNIT 1113
TRNITYIRD OXFORD,CT 06478
PHONE;(203)262-9245
FAX:(203)262-9243
REPORT
Owens Corning Evaluation Report 037940.02.12-RS
One Owens Corning Parkway FL10674-RI0
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 5: 04/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida,The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described
herein have been evaluated for compliance with the Sat Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance docurnentation changes. TrInityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT' The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its,
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through 6.
Prepared by:
J
Ille f6clinlitc teat apnexjngw%Awhotne,!bvRobed Ms-tv.,
Robert J.M.Nieminen,P.E. dw,MI 101-At'll et,,tt(<-0Y uA'1111
Florida Registration No.59166,Florida DCA ANE1983 document.5,90.d.iefld tuopiei nue h"n tt,-d to Olt,
Product Apter"al Ad.ij,pitt.,and Ill the 011"Ied client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing product',for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5, This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen,P,E,are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
a ,
TRINITY ERa
ROOFING SYSTEMS EVALUATION:
I. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance
with the following sections of the Florida Building Code and Florida Building Cade, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.5,R90S.2A Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6,1 Wind Resistance ASTM D3161 2009
1507,2..7.1,8905.2.6.1 Wind Resistance ASTM D7158 2008
3. REFERENCES:
EfftF,ty ExanipAorl 8-efetnrm Dace
UL LLC(CER9626) Physicals&Wind Resistance File 82453,Vol.3 02/I5/2007
UL I.LC(CER9626) Physicals&Wind Resistance 20120516-R2453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
Ul.LLC(TS79628) Physicals&Wind Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
Miami-trade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.0 8120/2 0 1 7
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2. Berkshire are fiberglass reinforced,4-tab asphalt roof shingles.
4.1.3 Devonshire-are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration', Duration' Premium Cool, TruDefinition' Duration' Designer Color Collection,
TruDefinition'Oakridge',Oakridge and WeatherGuard'HP are fiberglass reinforced,laminated asphalt roof shingles.
4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip & Ridge Shingles,
ProEdge Hip &Ridge Shingles and DuraRidge'"Hip&Ridge Shingles are fiberglass reinforced, hip and ridge asphalt
roof shingles,
4.3 Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation, Neither Trinity(ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report;refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and 8905.2.6.1 to
ASTM 03161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to
V,4d=150 mph(V„r,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,.indicating the shingles are acceptable for us in all wind zones up to
V.1d=150 mph(V,,,,=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate a/Autheritotion 09Stt3 FL10674-RIO
Revision 5:04/22/2015
Page 2 of 6
i TRINITY ERD
5.4.3 Classification by ASTM 07158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Cade and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underiayn,ent:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordance with FBC Sections 1507.7.or R905.2,with the following exceptions:
;^ Berkshire*shingles require minimum five(5)nails per shingle.
r WeatherGuard'MP shingles require minimum six(6)nails per shingle.
Devonshire'"shingles require minimum six(6)nails per shingle.
r Starter Strip Pius requires minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing–Classic°&Supreme:
Normal Mansard or Aro&par& Normal Mansard or Area para
Wind Areas Nigh Wind deavanss y Wind Arae Nigh Wind deavenes y
Arra psr&vfonto#normsrss Arose vfsntoa tusrres Area para viontos normal*# Areas vlontoa fuartas
z tel _�-fAl
i•
6'Exposure 4 818"Exposura
ExpoaleJ6n Expos106n
6.2.6 Minimum Nailing–Berkshires:
SPabM rtrip S abMsirfn
La t4adr xCada Ca pra do utradar
=24-Ir f7" A tY A ti' } R YP R Yf R}Y R�'?` }
,' �•J r t"1
i
Z* Asphax w4inilenmani
Crmcniads ttttto4sa+taro
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-RS
Certificate of Avthorkation#950 FL10674•RIO
Revision S:04/22/2015
Page 3 of 6
TRINITY ERD
6.2.7 Minimum Nailing—Devonshire":
Nails
Ten 1**Spots of Asphalt Roil Ctment
6,2.8 Minimum Nailing—Duration*,TruDefinition®Duration,Durations'Premium Coot&TruDefinition•Duration Designer
Color Collection:
4 Nag PAtian 6 Nei
Ejquentj do 4 clavob Pattern
Esquem;I
SU
kqlairltbie"ing arcs width do 6 c13 vos
Arca do dates SumtJal
A,-
12- 11
SV.'EXPOUrt U2i6 SW Expaswe ttt
S"i posy.C4#-VpGV(,bn CbVO% S%;w19,drAVpQ*J*n
W EXp(KUro flag,
appn
6.2.9 Minimum Nailing—TruDefinitlon Oakridge",Oakridge":
4 NA PAtQtn 6 Nall PA#M
Esquava con 4 clavo5 Esquoina cart 6 eiavvs
Ss/W Expowto ttaift
j 6 Sff Exposure track
E%pp%icitin de 6 GISPIdo. ClAY&F Exposiduade651909, 6 Sff Expoure claras 66/0'eprpow.
apodchondo,6619pulg. Expasarba de 6 Wpaj.
6.2.10 Minimum Nailing—WeatherGuarda HP:
111111glo ebb Vbw
Vftft
t
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5
Certificate of Autharicatlon 99503 FL10674-RI0
Revision 5:04/22/2015
Page 4 of 6
,i' -TRINI-IY ERD
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard HP Hip and
Ridge Shingles and ProEdge Hip&Ridge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle. installation of DuraRidge-Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,using two(2)nails per shingle. Refer to Owens Corning published infurmation on wind
resistance and installation limitations,including the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements,but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing-Berkshire"Hip&Ridge and High Ridge:
Ftp.2 j
,{.., M 14f
Ntl .r � � f-V NOW. W.M.-
tiaYs '-- ��`
� P �. t77li5 Bala i i
- .__.
...,.
I .,.�:�\ \'fir=� . � t :�• }
r r
777 q
i
6.3.4 Minimum Nailing-Hip&Ridge with Sealant:
elm Fig.2 -High Wincl Fastening Pattern
K Nails)
rim Shingle
nd Discard 2,r �
$e.�latitt ----►
Strip T 12"•
' Fastening 5518 5"Exposure
Distance
12"
6.3.5 Minimum Nailing-WeatherGuardd4 HP Hip and Ridge:
Fig.C Hip&Ridge Shingle Fastening
Fig.A - _a!_. :oyvw:
PCtZI Vj
A
!bike
I r1g4WN -\ t; EXPO30M
7 �
\ S
Exterior Research and Design,LLC. Evaluation Report 037940.02.12•RS
Certilicate oJAuthorhadon 09503 F1,10674-1110
Revision 5;04/22/2015
Page 5 of 6
TRINI-ry ERD
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard t1.
Wind OiraretionFastening
Sealant Strip Pattern
6'Exposure
s
12' Sealant
Fasten 71W 7�'« 0`Exposure
Cover Exposed
Frstenen with
Raaf Cement
6.3.7 Minimum Nailing—DuraRldge"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
,«,_r►o.aitn®Wind Oitadtm Yuip —
piroaiandtm7rane®dtsa't �y vnusvpe.ror i'r+
Oirardtt3Qdsiatta prodxnirueta �I
tl3iti--- eN.-.a.4r I �± -� Qwttn CaNn�5utz#ie++t' r•"
lots r .._r i
t
1 1 or
p�ntt kx $
f!.... :�•_ �-- 111
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
% MANUFACTURING PLANTS:
Contact the named OA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann ui.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-RS
Cenif_lrete of Aurhorkotion 09S03 FL10674•R 30
Revision 5:04122/2015
Page 6 of 6