Loading...
HomeMy WebLinkAboutProduct Approval (2) Honda Building Code Onlinef CEI Y a� �g Page t of 2 GLJ ��� V C92915 ,„„.... .' ” i �.�.. ,,. ._>._.._« ,.;.d. .:���r ,.�ro,'i •s�w"" -',�^^ an.^°'.Jl T:","'+`'`'{:.�'�`"p'6 •a;q7��”` �s�--` D:ti ,t9 f�`e,+'� i?~3d43ikk,•�f.�a:Y.�. {..,ss (� p.{�f. RCIs Home Log in user Registration Hot ropio Submit Surtharge Slat.E Facts Publications FIX Staff HqS Site Hap Unks eve, Professional iProdu 1 (a �SS�0i1�I USER:PublicAUser PPrOVdt Praasjrt Qiyrimrnt hie. >P'Mt'n Q.h�niififtnls.KS?rr��>Annly nunn i M>Application Detail 4 5 FL# Application Type Revisions�. Code Version 2014 Application Status f Approved Comments _ Archived I Product Manufacturer Owens Corning I Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.catit COP Authorized Signature Greg Keeler greg,keele r@owenscorning.com Technical Representative Address/Phone/Email i Quality Assurance Representative Address/Phone/Email i Category !_,--Roofing Subcategory Underlayrpents'/ ---- 1 Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received s 1 Florida Engineer or Architect Name who developed the Zachary'R.Priest I Evaluation Report i Florida License PE-74021 Quality Assurance Entity --ut LLC"-^- Quality Assurance Contract Expiration pate12/31/2020 1 ; Validated By ----Locke-Bowden Validation Checklist-Hardcopy Received i Certificate of Independence EL9777 R4 CO, ClCR1400,7,! FfS 2014 EvaluaEi.tan Epp ert 'O,LtI FE3tffi Y/�attteil+2fk.t2,df j 1 1 Referenced Standard and Year(of Standard) ss...i_-d j ]Leat ASTM O 1970 2009 Equivalence of product Standards � Certified By I Sections from the Code i l I hllps:ilfloridabuilding.org/prlpr app_dtl.aspx?param--wGEVXGwtDgtgkcMGblcW71a/Q2tZr7gdugvKmDi6kDHt6tY"/a3d July 1,2015 I Florida Building Code Online Page 2 of 2 Product Approval Method Method I Option D Date Submitted 02/23/2015 Date Validated 02/24/2015 Date Pending FBC Approval 03/0112015 Date Approved 04115/2015 Summary of Products FL# Model,Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment .............. Limits of Use Installation Instructions Approved for use In HVHZ:No EL2ZZ7 R4 11 OCR 4QQ2.1 FBC 2QI4 Ey Approved for use outside HVHZ.Yes i.E Impact Resistant:N/A Verified By: Zachary R. Priest 74021 Design Pressure;WA Created by Independent Third Party:Yes Other.,See evaluation report for limits of use. Evaluation It6port5 FL9777 R4 -!SE—OCR Created by Independent Third Party;Yes 9777.2 Weatherlock MAT Waterproofing:Underlayment Limits of Use #installation instructions Approved for use In HVHZ:No EQ777 R4 It OCRI,1002.1 Ft5C 2014 Approved for use outside HVHZ:Yes FDC WeatherLbrk,od Impact Resistant:NIA Verified By: Zachary R.Priest 74021 Design Pressure:N/A Created by Independent Third Party:Yes Other*See evaluation report for limits of use. Evaluation Rieports EL9777 84 AE FBC 2014 12010 1 Created by Independent Third Party:Yes 9777.3We­.'hezo­ck Specialty-- - ­–T lie ro pofing_Ynderlayment I.. __' _1_____1­­_.___'­_­ __nt — 9777.3 ._Weatherlock Limits of Use Installation instructions Approved for use In HVHZ:No Ft 17777 R4 I[! OCR14 I 4 Approved for use outside HVHZ-.Yes Impact Resistant:N/A j Verified By: Zachary R.Priest 74021 Design Pressure:N/A Created by Independent"third Party,Yes Other.See evaluation report for limits of use. Evaluation Reports Created by Independent Third Party.Yes .. .................. Coin ff if,%::1940 North MAn—Since? TallA10—El 12M j2ipR9;_a.CdU-117-IRY4 The State of Florida is an ANEE0 employer,C=,Iht 71107.2ni A State ol.Ficirld ;:r( V jVAc_f"moP,d:1&t...+fljts 11,jermni„Iteball.%jalliLtigat Under nornpir low,email addresses ars,public,records.It you do not want your e-mail addressreleased in response to a public-rocords terjue5t,do not send elcttromt mail to this entity.Instead,contact the office by phone or by traditional mail.it you have any qUeS.110,11,please contact 950.497.1395.onursuant to Section Florida statutes,effective Octotser.i,2012.licensees licensed under chapter 455,F,S.Must provide the Department with an email address it they have one.The eirsaids provided may bit used for official communication with the licensee.However email addresses are public record,If you do not isf%ti to supply d per5onjl address,please provide the department with all email address which can be made available to the pubis,c.To determine if YOU are a IlCenSue Under Chapter 455,F.S_ please click b=. Product Approval Accepts- RE 110=1 F- M hitps:llfloridabuilding.org/prlpr�_app_Atl.aspx?parani--ArGEVXQwtDqtgkcMGbIcW7Wo2fZr7gduqvKmDj6kDH 16tY%3d July 1.2015 Certificate of Authorization No. 29824 17520 Edinburgh Drive CREEK Tampa,FL 33647 TECHNICAL SERVICES, LLC {813)4$0-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued February 23, 2015 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 yAvw.qwenscoming.com Manufacturing Location: Brentwood,NH Quality Assurance: UL LLC(QUA9626) SCOPE Category: Roofing Subcategory: Underlayments Code Sections; 1507.2.4, 1507.2.8. 1507.2,9.2, 1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3,1507.5.3.2, 1507.7.3,1507.7,3.2, Properties: Physical properties REFERENCES Entity Standard Year Report No. )L— PRI Construction Materials Technologies(TST6049) NEI.039-02-01 ASTM 0 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-042-02-01REV2 ASTM D 1970 2009 PRI Constaiction Materials Technologies(TST6049) NEI.045-02-01 TAS 103 1996 PRI Construction Materials Technologies(TST6049) NEI.04"2-01 ASTM G 156 20051 PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI.053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLockO G is an ASTM 0 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles. wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mal is an ASTM D 1970 sell-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcem ent. The product is supplied in 1- sq. -sq.rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockO Mat Is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ WeatherLockO Specialty is an ASTM D 1970 self-adhesive underlayment constructed Specialty Tile&Metal from SBS modified asphalt and surfaced with a non-woven polyester fabric. The product is supplied in 2 sq.rolls with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq, rolls with OCR14002A F1.9777-114 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3,`The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are not specifically addressed heroin. OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LLC nominal dimensions of 3-ft x 71.3-ft. WeatherLock@ WeatherLock@ Specialty Tile&Metal is permitted to be used with mechanically fastened Specialty Tile&Metal asphalt shingles, clay or concrete file, metal roof panels or shingles, wood shakes or (continued) shingles, and state roofing as prescribed in the FBC. Weatherl-ocke Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MT'i 2-Componant Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BONDT", Roof Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of -45 psf and in accordance with the system approval. Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. PRODUCT APPLICATION Min.Roof Slope: 2:12 or in accordance in with FBC Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be chocked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the undortayment shall be unrolted and allowed to relax for a minimum of 3-6 minutes. The underlayment shall be installed direct-to-plywood decking with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3'side laps and minimum W staggered end laps. End laps for WeatherLock@ Specialty Tile&Metal shall be primed,with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). WeatherLockED Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, the underlayment should extend to a point 24-inches inside the exterior wall. The underlayment shall be installed over metal drip edge at the eave.and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min.Application 40°F;Contact the manufacturer when installing at temperatures below tile minimum Temperature: application temperature. GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application Instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for now or existing construction. 5) The space under the deck area shall be property ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCRI4002.1 FL9777-R4 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61020-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the,duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLC CREEK WoatherLockO Solf-Seallng Ice&Water Barriers TECI-INICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. R 2015.02.2 .-'\GEN, 3 14:45:39 No 74021 -05'00' -33% STATE OF 0 .. Zachary R.Priest,P.E. 0 FtFlorida Registration No.74021 "i,,,ONM_0•`x`14 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services.LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCRI4002.1 FL9777-R4 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shelf notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.