Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com July 10, 2015 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 76 EI Mar Drive,St. Lucie County Building Department Manufacturer: POLYGLASS USA Profiles: Modified Bitumen Noa# 13-0514.10 Code: FBC 2010;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30` Maximum Pitch: 1/12 Required Design Pressure: Zone1: -42.1 Zone 2: -50 Zone3: -96.3 Maximum Uplift Pressure: -60.0 psf Zones 1& 2, -120 psf Zone 3 Base Sheet: Elastobase Fasteners: Attach base sheet using 11 ga. annular ring shank & 1-5/8" diameter tin caps @ 8" o.c. in a 4" lap &8" o.c. in three equally spaced rows in the center of the sheet for zones 1 & 2 and 4"o.c. in a 4" lap &4"o.c. in three equally spaced rows in the center of the sheet for zone 3 Underlayment: Elastoflex Sav,self-adhered Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6"o.c.thru out Zone 1,4" o.c. perimeter& 6" o.c. field Zone 2, and 4" o.c.thru out Zone3 The above approved, as per Florida Building Code Compliance acceptances, 2010 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted, Peter B. Cook . Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789