Loading...
HomeMy WebLinkAboutEngineering 7F 1 COPY PAUL WELCH INC. FILE Mechanical Electrical Civil Engineering ` 1984 S.W. Biltmore St. Suite#114 I �� ��✓� Port Saint Lucie,FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com July 14,2015 Re: Zavala-Corona Re-Roof 401 N 37th Street Fort Pierce, FL 34947 SCOPE OF WORK: Remove existing roofing and install new 5-V Crimp Metal Roof(Union Corrugating Company FL# 7271.5) at above referenced residence address over new underlayment and existing plywood sheathing. DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=8-0" A=3' MEAN ROOF HIEGHT=<15' ROOF ANGLE=4:12 SHAPE=PITCHED GABLE RvIPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 160 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=C ENCLOSURE CLASS =ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (Psf): ZONE 1 (Field)=-38.7 ZONE 2 (Perimeter/Ridge)_-64.9 ZONE 3 (Corners)_-97.7 "Paul Welch Inc. ' Paul Welch-P.E. Reg. No. 29945 July 14, 2015 401 N 37th Street Fort Pierce,FL 34947 1 of 3 r�- ATTACHMENT REOUM— MENTS: Metal roofing to be attached with#9- 15 x 2"long(minimum 114"penetration through plywood sheathing)wood screws with weather sealing washers spacing as follows: ZONE 1 (Field): Fasteners in ribs(Pattern 2 per product approval)at 12" O.C. ZONE 2(Perimeter/Ridge): Fasteners in ribs(Pattern 2 per product approval)at 12" O.C. ZONE 3(Corners): Fasteners in ribs(Pattern 2 per product approval)at 12" O.C. Also Provide Fasteners at 6" O.C. in the flat of the panel and ribs at panel ends all perimeter of the roof eve. Zones 1,2 &3 Design uplift Pressure: -113.1 psf Zones 1,2&3: 113.1 >97.7>64.9>38.7 Therefore Q.K. UNDERLAYMENT INSTALLATION: Underlayment shall be Unless otherwise noted, required underlayment shall conform to ASTM D 226,Type I or Type II, or ASTM D 4869 Type I or Type II or ASTM D 6757. nderlayment shall be one layer applied in the following manner. Underlayment shall be applied shingle fashion,parallel to and starting from the eave and lapped 2 inches(51 mm), fastened sufficiently to hold in place. Distortions in the underlayment shall not interfere Metal Roof Panel installation. DECD INSTALLATION: Re-nail all plywood sheathing(19/32"thick minimum)with 8D ring-shank nails at 4"Q.C. perimeter and 6"Q.C. field for all zones. All work to be in compliance with product approval (FL#7271.5),manufacturer's specifications,and the Florida Building Code 2014. Submitted by: PAUL WELCH IN . Paul Welch,P.E. Reg.No 29945 PW:pj 401 N 37th Street Fort Pierce,FL 34947 2 of 3 J* : r i H li I 1 J i I i �u E f i � ROOF ZONE PLAN A=3' (D,0, ZONE DF'FSIIGNA770N(TYPICAL) Note:All Zones Require Some Attachments �'atti�fi?"elch Inc. Paul Wel&P-R-Reg.Na 29945 July -2015 `f 3 of 3 401 N 37th Street Fort'Pierce,FL 34947