Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com July 14, 2015 A9 Saint Lucie County Building Department lie Attn: Roof Permit Plan Review ®IP,pi 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 10420 Glades Cut off Rd.,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply&Manufacturing Profiles: 26 GA 5v Crimp Roof Panel FL.#11651.12 Code: FBC 2014; Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 5/12 Required Design Pressure: Zone1:-46.2 Zone 2: -65.2 Zone3:-122.6 Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12" o.c., &-156.5 @ 6" O.C. Fasteners: #9-15 x 1%Z" HWH w/Sealing Washer with%" minimum penetration spaced @ 12"o.c. zone 1& 2, & 6" o.c. zone 3 Underlayment: Soprema, Inc. FL#2569.1 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced,film-surfaced,sbs modified bitumen Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru out Zone 1,4" o.c. perimeter& 6" o.c.field Zone 2, and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Respe9tTylly Submitte , Pe ter B. Cook Cook& Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789