HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460-4244
EMAIL cookmenard@yahoo.com
July 14, 2015
A9
Saint Lucie County Building Department lie
Attn: Roof Permit Plan Review ®IP,pi
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at
10420 Glades Cut off Rd.,Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply&Manufacturing
Profiles: 26 GA 5v Crimp Roof Panel FL.#11651.12
Code: FBC 2014; Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: C
Mean Roof Height: 30' Maximum
Pitch: 5/12
Required Design Pressure: Zone1:-46.2 Zone 2: -65.2 Zone3:-122.6
Maximum Uplift Pressure: Fastener spacing:-108.5 psf @ 12" o.c., &-156.5 @ 6" O.C.
Fasteners: #9-15 x 1%Z" HWH w/Sealing Washer with%" minimum penetration spaced @
12"o.c. zone 1& 2, & 6" o.c. zone 3
Underlayment: Soprema, Inc. FL#2569.1 Lastobond Smooth Seal HT is a self-adhering, glass-mat
reinforced,film-surfaced,sbs modified bitumen
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c. thru
out Zone 1,4" o.c. perimeter& 6" o.c.field Zone 2, and 4" o.c.thru out Zone3
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
Respe9tTylly Submitte ,
Pe ter B. Cook
Cook& Menard Architecture, Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789