HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
3
ki
pine;: pamer'd BCIS Home Log In User Registration Hot Topics ( Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search i
Bpusines �), g}
PUfS..$S' n 1' - USER:Public
Regulation
Product Approval Meng>Product or Application Search>Application List>Application Detail
FL# FL14095 R
Application Type on
Code Version 201
Application Status Approved
Comments
Archived
Product Manufacturer JELD-WEN
Address/Phone/Email 3737 Lakeport Blvd
Klamath Falls,OR 97601
(800)535-3936
fbcl@jeld-wen.com
Authorized Signature Kaede McLaughlin
fbcl@jeld-wen.com
Technical Representative JELD-WEN Corporate er Service
Address/Phone/Email 3737 Lakeport Blvd.
Klamath Falls,OR 9760 y
(800)535-3936
customerserviceagents@je
Quality Assurance Representative
Address/Phone/Email
Category WindoDHu
Subcategory le
Compliance Method Certification Mark or Listing Ike%
Certification Agency National Accreditation&Management Institute
Validated By National Accreditation&Management Institute,
Referenced Standard and Year(of Standard) Standard Year
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
I affirm that there are no changes in the new Florida
Building Code which affect my product(s)and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity �;Yes C'No O N/A
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCBy. 7/8/2015
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option A
Date Submitted 02/20/2015
Date Validated 02/20/2015
Date Pending FBC Approval
Date Approved 02/28/2015
Summary of Products
FL# Model,Number or Name Description
14095.1 Premium Atlantic Vinyl Single Hung (8100)36"x 72"Insulated Glass(5/16 in PVB or SGP Lam-
1/8 out Annealed )
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC NI011567.04-R2.Pd
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 04/30/2017
Design Pressure:+65/-70 Installation Instructions
Other:Miami-Dade NOAs for Quanex FL14095 R5 I1 DP65-70 36x72 Impact Installation Instructions.odf
Building Products,Inc PVC(12-1017.02 and FI-1.4095 R5 11 DP65-
13 0425.15). Miami-Dade NOAs for Dupont 70 36x72..Wo_gd_TtlrouyhFr rne_Irnil<jctInstallatidn,Instructions.PDF
SentryGlas(11-0624.02)and Butacite PVB Verified By: Hermes Norero,PE 73778
(13-0129.27)Interlayers. IG back bedded Created by Independent Third Party: Yes
with Dow 995. Evaluation Reports
FL14095 R5 AE PER3094.0
Created by Independent Third Party:Yes
14095.2 Premium Atlantic Vinyl Single Hung (8100)36"x 72"Insulated Glass(1/8 in-1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC N1011567.08-NI011567.09.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/30/2017
Design Pressure:+65/-70 Installation Instructions
Other:Miami-Dade NOAs for Quanex H-1.4095 R5 II 36x72 DP65-70 Installation.pdf
Building Products,Inc PVC(12-1017.02 and FL14095_R5 11 3fix72.._DP65-70 Throu,gh_Frame Wood.._Installation.PDF
13-0425.15).IG back bedded with Dow 995. Verified By: Hermes Norero,PE 73778
Created by Independent Third Party:Yes
Evaluation Reports
FL14095 R5 AE PER3092.0dF'
Created by Independent Third Party:Yes
14095.3Premium Atlantic Vinyl Single Hung(8100) 52 1/8"x 75"Insulated Glass(3/16 in-3/16 out
Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL l0 R5 C CAC NIii11567.06-NI011567.07.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/30/2017
Design Pressure: +65/-70 Installation Instructions
Other: Miami-Dade NOAs for Quanex FL14_11 R5 II S2_125x75 DPOS-7Q...._I11stallati0n.0df
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II 52.125x75 DP65-
13-0425.15).IG back bedded with Dow 995. 70 'T"hr0uoh Frame Wood Installation,PDF
Windows with insulated glass units wider than Verified By: Hermes Norero,PE 73778
36"require setting blocks. Created by Independent Third Party:Yes
Evaluation Reports
FL14095 R5 AE PER3093.pdf
Created by Independent Third Party:Yes
14095.4 Premium Atlantic Vinyl Single Hung (8100)52 1/8"x 75"Insulated Glass(5/16 in PVB or SGP Lam
1/8 out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC N1011567.02-Rl.pdf
Approved for use VHZ:Yes Quality Assurance Contract Expiration Date
Impact Resist t.Yes 04/30/2017
Design Press re: +50/-60 Installation Instructions
Other: Miami- s for Quanex FL.1.4095 R5 11 DP50-60 52.125x75 Impact Installation Instructions.pdf
Building Products,Inc PVC(12-1017.02 and FL14.095 R5 11 DP50_.
13-0425.15).Miami-Dade NOAs for Dupont 60 52.125x75 Wood Throuah Frame Impact Installation Instructions Ddf
SentryGlas(11-0624.02)and Butacite PVB Verified By: Hermes Norero,PE 73778
(13-0129.27)Interlayers.IG back bedded Created by Independent Third Party:Yes
with Dow 995.Windows with insulated glass Evaluation Reports
units wider than 36"require setting blocks. FL14095 R5 AE PER3091.odf
Created by Independent Third Party:Yes
14095.5 Premium Atlantic Vinyl Single Hung (8100)52 1/8"x 75"Insulated Glass(5/16 in SGP Lam-3/16
out Annealed)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL14095 R5 C CAC NI011567-NI011567.01.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtGLR%2byCBy... 7/8/2015
Florida Building Code Online Page 3 of 3
Impact Resistant:Yes 04/30/2017
Design Pressure:+65/-75 Installation Instructions
Other: Miami-Dade NOAs for Quanex FLl 1095 R5 II DP65.-75 52.125x75..,,If pAg Installation Instructions.ndf {
Building Products,Inc PVC(12-1017.02 and FL14095 R5 II DP65-
13-0425.15).Miami-Dade NOAs for Dupont 75 52.125x75 Wood Through Frame Impact Installation Instructions.odf
SentryGlas(11-0624.02)and Butacite PVB Verified By: Hermes Norero,PE 73778
(13-0129.27)Interlayers. IG back bedded Created by Independent Third Party:Yes
with Dow 995.Windows with insulated glass Evaluation Reports
units wider than 36"require setting blocks. Fu1.1.4095 R5 AF.. PFR3095.Ddf
Created by Independent Third Party:Yes
Back Next
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® EGIi:, ..'.r
sceuritv'vf:-r itar.E
sAk
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtGLR%2byCBy... 7/8/2015
14''t�0u. . .......__................................_.__.....................___......-- ----._.._.._..---..........__..............._._.............._-..._............_.......................... THROUGH FRAME
_...----
------------------ —— i I---
. . .
MIN.DISTANCE
-r--- --t-' I Fop EDSE:3/4n 3 INSTALLATION _^
.—...__........_......................-------—
Min.
i EMBEDMENT
tRa-O.C.
1112"MIN.
Mo.THRU I EMBEDMENT
imp I/4"MAX +1A"MAX
SHIM SPACE SHIM SPACE
3
?TT
3run 3mm I
I i MIN.DISTANCE 2
FOR EDGE:3/4"
GLASS 611E j
{ I
A
JAMB SECTION(TYP)
GLAZING DETAIL MORI20NTAL SECTION
FRAME SECTION(TYP)
j VERTICAL SECTION
lY.TE:fniN a'mn Nziiq Rn+.A Vtsf C..�eq
1/a Max
SHTMSFACc —___._._............_......._..._.__........................
g —1112"MM , PREMIUM ATLANTIC VINYL SH UVTND01tV
EM3EDMENT I ! Max Frame DP RATING IMPACT
l+WWar mon+(az,/e•MAX ' ,
52 1/8 x 75 +50/-60 YES
MIN,DISTANCE I �
TYPICAL ELEVATTON WITH FASTENER SPACING ; FOR EDGE:3/4"
LARGE MISSILE IMPACT
...... — .—...----.._...........................
-- —
Installation Notes: General Notes:
1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
112"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300.
to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
project of installation. DuPont-3mm annealed...
4. Use structural or composite shims where required.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: 3737 Lakeport Blvd
not address he sealing consideration that may arise in different wall -- 08/13/2014
conditions. For the complete installation procedure,see the instructions DRAWN BY: SCALE: JMWWENKlamath Falls,OR.97601
packaged with the window or go to D.Vezo NTS Phone: (541)882-3451
CHECKED BY: TITLE:
wwvi.jeld-wen.com/resources/installaflon. Addendum to NAMI J. Kantola
DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
on No.: a l i 56 2 -Z -
This drawing and its contents are confidential and are not to be R ft P RT PRO CT No
reproduced or copied in whole or in part or used or disclosed to others g 8129
except as authorized by J ELD-WEN Inc. ER No. PLANT NAlaE AND LOCATION: CAD DWG.No.: REV: SHEET
'AS NCTL210-3874- -FBC 001 20F i