Certification for Design load Compliance
Project Name: Entry Door Replacement(unit front doors)
Project Address: 10410 S. Ocean Dr,Jensen Beach, Florida
Permit#: Occupancy Type: Residential Construction Type:Concrete/Masonry
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record. _
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.•
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida yes Code 2010 Edition with 2010 Supplements using ASCE 7-10
2. Structure Designed as(check one): Yes Enclosed Partially Enclosed Open
3. Risk Category: _I x II III IV Exposure Category: B C x D
4. Design Wind Velocity 160 mph(ult) mph x ASD LRFD End Zone Width: 15 ft
S. Mean Roof Height 110 ft Roof Pitch: flat :12 Parapet: ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):
Zone 1: Zone 2: Zone 3: Zone 4: +-60 Psf Zone 5: Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why Not:
(door framing to building floor diaphgrams)
10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify iit��4` °94 tooe�s°i�q#,rmy knowledge and belief,the attached plans&specifications have been designed to
compw6l,wii��J p. + L tural portions of the building codes currently adopted and enforced by St. Lucie
Cot��Q at' thal" utte'tral-elements depicted on these plans provide adequate resistance to the design
foepeci
---John D. Breitenbach PE 59770,26001
O� =Lu=_ Print Name Cert#&Co.Cert Auth.
SSP.- •: Breitenbach Engineering, Inc
' FLp���'
Signata'N a � ,e�`` 4853 SE Pilot Way, Stuart, Florida 34'997
�A`P°Rcroaeit,��+dti+,���,` Company Name&Address
Revised 07/25/2014