HomeMy WebLinkAboutWind Load Calculation 5 J Planning&Development Services Department ® � N Building&Code Regulations Division 2300 Virginia Avenue, Fort Pierce,FL 34982—(772)462-2553 Certification for Design load Compliance Project Name: Entry Door Replacement(unit front doors) Project Address: 10410 S. Ocean Dr,Jensen Beach, Florida Permit#: Occupancy Type: Residential Construction Type:Concrete/Masonry INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. _ • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure.• * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida yes Code 2010 Edition with 2010 Supplements using ASCE 7-10 2. Structure Designed as(check one): Yes Enclosed Partially Enclosed Open 3. Risk Category: _I x II III IV Exposure Category: B C x D 4. Design Wind Velocity 160 mph(ult) mph x ASD LRFD End Zone Width: 15 ft S. Mean Roof Height 110 ft Roof Pitch: flat :12 Parapet: ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +-60 Psf Zone 5: Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? Yes X Not Applicable Explain Why Not: (door framing to building floor diaphgrams) 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify iit��4` °94 tooe�s°i�q#,rmy knowledge and belief,the attached plans&specifications have been designed to compw6l,wii��J p. + L tural portions of the building codes currently adopted and enforced by St. Lucie Cot��Q at' thal" utte'tral-elements depicted on these plans provide adequate resistance to the design foepeci ---John D. Breitenbach PE 59770,26001 O� =Lu=_ Print Name Cert#&Co.Cert Auth. SSP.- •: Breitenbach Engineering, Inc ' FLp���' Signata'N a � ,e�`` 4853 SE Pilot Way, Stuart, Florida 34'997 �A`P°Rcroaeit,��+dti+,���,` Company Name&Address Revised 07/25/2014