Loading...
HomeMy WebLinkAboutInspection Docs o This combination qualifies for a Federal Energy AMR[b E R11 F i,E bEfficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31,2014. rr Gertifidate of Product "'a in s . AHRI Certified Reference 14untber:.7943535 Date: 7/7/2015 Product: Split System:Air-Cooled Condensing Unit, Coil with Blower Outdoor Unit-Model-Number: RA1648AJ1 Indoor Unit Model Number: RH1T4821STAN Manufacturer::RHEEM SALES COMPANY, INC. Trade/Brand name: RHEEM9 RUUD Region: Region Note: Central air conditioners manufactured prior to January 1, 2015,are eligible to be installed in all regions until June 30;2016. Beginning July 1,2016, central air conditioners can only be installed in region(s)for which-they meet the regional efficiency requirement. Series name:' Manufacturer responsible for the rating of this system combination is RHEEM SALES COMPANY, INC. Rated as follows in "accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and.Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent;third party test) cooling Capacity(Btuh): .45000 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 IEER Rating(Cooling): .'Ratings folfowed by an asterisk(`)indicale a volunlwy rerale of previouSly published data,unless accompanic>d,with a WAS;which indicates an involuntary rerale. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS ®� This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link ire malw life heuLl" and enter the AHRI Certified Reference Number and the date on which the Certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130807584955409709 Project Summary J b: daza ED Jul 13, 015 Entire H o Use hris pher T.Rizzo • • • For: Daza 322 se.Tranquilla ave, Psl, FI -Notes:- Desian Inform,atioln, Weather: Vero Beach; FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 15 OF Daily range L Relative Humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure. 28850 Btuh Structure 27332 Btuh Ducts 6463 Btuh . Ducts. 9940 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) - 0 Btuh Humidification 0 Bt.uh Blower. 0 Btuh _Piping 0 Btuh Equipment load 35313 Btuh Use manufacturer's data n Rate/swing multiplier 0:.95 Infiltration Equipment sensible-load 35409 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality' Average Fireplaces. . 0_ _ Structure 4578 Btuh Ducts. . . 2713 Btuh Heating.. Cooling- Central vent.(0-cfm) 0 Btuh Area(ft2). 2172: 2172.. Equipment'latent load-:." 7291: Btuh Volume(ft3). . 19548 19548 . Air.changes/hour 0.32 0.1.6. . Equipment,total load 42699 Btuh. Equiv:AVF(cfm) 104 52 Req: total capacity.at 0.70 SHR'.. 4.2. ton Heating Equipment Summary. Cooling Equipment Summary Make Make Ruud: Trade . Trade Model Gond . RA1648AJ1 AHRI ref- .Coil RH1T4821STAN A H R I ref 7943535 Efficiency 100 EFF Efficiency .11.0 EER, 16 SEER Heating input 10.4 kW Sensible cooling 31500 Btuh Heating output 35497 Btuh Latent cooling 13500 Btuh Temperature rise 22 OF Total cooling 45000 Btuh Actual air flow 1500 cfm Actual air flow 1500 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� Wrl htsoft' 2015-Jul-1309:48:32 9 Right-Suite®Universal 201212.1.08 RSU02908 Page 1 H:WIyDocumentslAeatloadsU)aza.rup Calc=MJ8 FrontDoorfaces:N